EquivalentRadiatedPowerWaterfallDiagram
#
- class ansys.mechanical.stubs.v242.Ansys.ACT.Automation.Mechanical.Results.FrequencyResponseResults.EquivalentRadiatedPowerWaterfallDiagram#
Bases:
object
Defines a EquivalentRadiatedPowerWaterfallDiagram.
Overview#
|
Run the ClearGeneratedData action. |
|
Run the EvaluateAllResults action. |
|
Run the FetchRemoteResult action. |
|
Run the ExportToTextFile action. |
|
Run the ExportAnimation action. |
|
Run the DuplicateWithoutResults action. |
|
Creates results at all sets for results under a solution. |
|
Run the PromoteToNamedSelection action. |
|
CreateParameter method. |
|
Creates a new Alert |
|
Creates a new Convergence |
|
Run the RenameBasedOnDefinition action. |
|
Run the Delete action. |
|
Gets the list of children, filtered by type. |
|
Gets the list of children, filtered by type. |
|
Creates a new child Comment. |
|
Creates a new child Figure. |
|
Creates a new child Image. |
|
Activate the current object. |
|
Copies all visible properties from this object to another. |
|
Creates a copy of the current DataModelObject. |
|
Run the GroupAllSimilarChildren action. |
|
Run the GroupSimilarObjects action. |
|
Get a property by its unique name. |
|
Get a property by its API name. |
|
Gets the parameter corresponding to the given property. |
|
Removes the parameter from the parameter set corresponding to the given property. |
|
Gets the internal object. For advanced usage only. |
|
Gets or sets the PanelsToDisplay. |
|
Gets or sets the DisplayPanel. |
|
Gets or sets the PanelContribution. |
|
Gets the current DataModelObject’s category. |
|
Gets the result table. |
|
Gets or sets the Location. |
|
Get the Time for the minimum of minimum values. |
|
Get the Time for the minimum of maximum values. |
|
Get the Load Step for the minimum of minimum values. |
|
Get the Load Step for the minimum of maximum values. |
|
Get the Time for the maximum of minimum values. |
|
Get the Time for the maximum of maximum values. |
|
Get the Load Step for the maximum of minimum values. |
|
Get the Load Step for the maximum of maximum values. |
|
Gets the IsSolved. |
|
Gets or sets the Coordinate System. |
|
Gets or sets the ScopingMethod. |
|
Gets or sets the Set Number. |
|
Gets or sets the Combination Number for a Solution Combination result. |
|
Gets or sets the SolutionCombinationDriver. |
|
Path property. |
|
Surface property. |
|
SurfaceCoating property. |
|
Gets or sets the NamedSelections. |
|
Gets or sets the Waterfall Mosaic Text Property. |
|
Gets or sets the CrackFrontNumber. |
|
Gets or sets the GlobalIDs. |
|
Gets or sets the Identifier. |
|
Gets the IterationNumber. |
|
Gets the LoadStep. |
|
Gets the MaximumOccursOn. |
|
Gets the MinimumOccursOn. |
|
Gets or sets the LoadStepNumber. |
|
Gets or sets the SolverComponentIDs. |
|
Gets the Substep. |
|
Gets the Average. |
|
Gets the Maximum. |
|
Gets the MaximumOfMaximumOverTime. |
|
Gets the MaximumOfMinimumOverTime. |
|
Gets the Minimum. |
|
Gets the MinimumOfMaximumOverTime. |
|
Gets the MinimumOfMinimumOverTime. |
|
Gets the Time. |
|
Gets or sets the DisplayTime. |
|
Gets or sets the GraphControlsXAxis. |
|
Gets or sets the DisplayOption. |
|
Gets or sets the DpfEvaluation. |
|
Gets or sets the By. |
|
Gets or sets the ItemType. |
|
Gets or sets the CalculateTimeHistory. |
|
Gets or sets the Suppressed. |
|
Gets the list of children. |
|
Gets the list of associated comments. |
|
Gets the list of associated figures. |
|
Gets the list of associated images. |
|
Gets the internal object. For advanced usage only. |
|
Gets the list of properties for this object. |
|
Gets the list of properties that are visible for this object. |
Property detail#
- property EquivalentRadiatedPowerWaterfallDiagram.InternalObject: Ansys.Common.Interop.DSObjectsAuto.IDSResultAuto | None
Gets the internal object. For advanced usage only.
- property EquivalentRadiatedPowerWaterfallDiagram.PanelsToDisplay: System.Int32 | None
Gets or sets the PanelsToDisplay.
- property EquivalentRadiatedPowerWaterfallDiagram.DisplayPanel: System.Boolean | None
Gets or sets the DisplayPanel.
- property EquivalentRadiatedPowerWaterfallDiagram.PanelContribution: System.Boolean | None
Gets or sets the PanelContribution.
- property EquivalentRadiatedPowerWaterfallDiagram.DataModelObjectCategory: Ansys.Mechanical.DataModel.Enums.DataModelObjectCategory | None
Gets the current DataModelObject’s category.
- property EquivalentRadiatedPowerWaterfallDiagram.PlotData: Ansys.Mechanical.DataModel.Results.ResultDataTable | None
Gets the result table.
- property EquivalentRadiatedPowerWaterfallDiagram.Location: Ansys.ACT.Interfaces.Common.ISelectionInfo | None
Gets or sets the Location.
- property EquivalentRadiatedPowerWaterfallDiagram.TimeForMinimumOfMinimumValues: Ansys.Core.Units.Quantity | None
Get the Time for the minimum of minimum values.
- property EquivalentRadiatedPowerWaterfallDiagram.TimeForMinimumOfMaximumValues: Ansys.Core.Units.Quantity | None
Get the Time for the minimum of maximum values.
- property EquivalentRadiatedPowerWaterfallDiagram.LoadStepForMinimumOfMinimumValues: System.UInt32 | None
Get the Load Step for the minimum of minimum values.
- property EquivalentRadiatedPowerWaterfallDiagram.LoadStepForMinimumOfMaximumValues: System.UInt32 | None
Get the Load Step for the minimum of maximum values.
- property EquivalentRadiatedPowerWaterfallDiagram.TimeForMaximumOfMinimumValues: Ansys.Core.Units.Quantity | None
Get the Time for the maximum of minimum values.
- property EquivalentRadiatedPowerWaterfallDiagram.TimeForMaximumOfMaximumValues: Ansys.Core.Units.Quantity | None
Get the Time for the maximum of maximum values.
- property EquivalentRadiatedPowerWaterfallDiagram.LoadStepForMaximumOfMinimumValues: System.UInt32 | None
Get the Load Step for the maximum of minimum values.
- property EquivalentRadiatedPowerWaterfallDiagram.LoadStepForMaximumOfMaximumValues: System.UInt32 | None
Get the Load Step for the maximum of maximum values.
- property EquivalentRadiatedPowerWaterfallDiagram.IsSolved: System.Boolean | None
Gets the IsSolved.
- property EquivalentRadiatedPowerWaterfallDiagram.CoordinateSystem: Ansys.ACT.Automation.Mechanical.CoordinateSystem | None
Gets or sets the Coordinate System. Accepts/Returns None for Solution Coordinate System in the general case (if applicable). Accepts/Returns None for Fiber Coordinate System for a result that is sub scoped by ply.
- property EquivalentRadiatedPowerWaterfallDiagram.ScopingMethod: Ansys.Mechanical.DataModel.Enums.GeometryDefineByType | None
Gets or sets the ScopingMethod.
- property EquivalentRadiatedPowerWaterfallDiagram.SetNumber: System.UInt32 | None
Gets or sets the Set Number.
- property EquivalentRadiatedPowerWaterfallDiagram.CombinationNumber: System.UInt32 | None
Gets or sets the Combination Number for a Solution Combination result.
- property EquivalentRadiatedPowerWaterfallDiagram.SolutionCombinationDriver: Ansys.Mechanical.DataModel.Enums.SolutionCombinationDriverStyle | None
Gets or sets the SolutionCombinationDriver.
- property EquivalentRadiatedPowerWaterfallDiagram.Path: Ansys.ACT.Automation.Mechanical.Path | None
Path property.
- property EquivalentRadiatedPowerWaterfallDiagram.Surface: Ansys.ACT.Automation.Mechanical.Surface | None
Surface property.
- property EquivalentRadiatedPowerWaterfallDiagram.SurfaceCoating: Ansys.ACT.Automation.Mechanical.SurfaceCoating | None
SurfaceCoating property.
- property EquivalentRadiatedPowerWaterfallDiagram.NamedSelections: System.Collections.Generic.IEnumerable[Ansys.Mechanical.DataModel.Interfaces.IDataModelObject] | None
Gets or sets the NamedSelections.
- property EquivalentRadiatedPowerWaterfallDiagram.WaterfallShowTextOnMosaic: System.Boolean | None
Gets or sets the Waterfall Mosaic Text Property.
- property EquivalentRadiatedPowerWaterfallDiagram.CrackFrontNumber: System.Int32 | None
Gets or sets the CrackFrontNumber.
- property EquivalentRadiatedPowerWaterfallDiagram.GlobalIDs: System.String | None
Gets or sets the GlobalIDs.
- property EquivalentRadiatedPowerWaterfallDiagram.Identifier: System.String | None
Gets or sets the Identifier.
- property EquivalentRadiatedPowerWaterfallDiagram.IterationNumber: System.Int32 | None
Gets the IterationNumber.
- property EquivalentRadiatedPowerWaterfallDiagram.LoadStep: System.Int32 | None
Gets the LoadStep.
- property EquivalentRadiatedPowerWaterfallDiagram.MaximumOccursOn: System.String | None
Gets the MaximumOccursOn.
- property EquivalentRadiatedPowerWaterfallDiagram.MinimumOccursOn: System.String | None
Gets the MinimumOccursOn.
- property EquivalentRadiatedPowerWaterfallDiagram.LoadStepNumber: System.UInt32 | None
Gets or sets the LoadStepNumber.
- property EquivalentRadiatedPowerWaterfallDiagram.SolverComponentIDs: System.String | None
Gets or sets the SolverComponentIDs.
- property EquivalentRadiatedPowerWaterfallDiagram.Substep: System.Int32 | None
Gets the Substep.
- property EquivalentRadiatedPowerWaterfallDiagram.Average: Ansys.Core.Units.Quantity | None
Gets the Average.
- property EquivalentRadiatedPowerWaterfallDiagram.Maximum: Ansys.Core.Units.Quantity | None
Gets the Maximum.
- property EquivalentRadiatedPowerWaterfallDiagram.MaximumOfMaximumOverTime: Ansys.Core.Units.Quantity | None
Gets the MaximumOfMaximumOverTime.
- property EquivalentRadiatedPowerWaterfallDiagram.MaximumOfMinimumOverTime: Ansys.Core.Units.Quantity | None
Gets the MaximumOfMinimumOverTime.
- property EquivalentRadiatedPowerWaterfallDiagram.Minimum: Ansys.Core.Units.Quantity | None
Gets the Minimum.
- property EquivalentRadiatedPowerWaterfallDiagram.MinimumOfMaximumOverTime: Ansys.Core.Units.Quantity | None
Gets the MinimumOfMaximumOverTime.
- property EquivalentRadiatedPowerWaterfallDiagram.MinimumOfMinimumOverTime: Ansys.Core.Units.Quantity | None
Gets the MinimumOfMinimumOverTime.
- property EquivalentRadiatedPowerWaterfallDiagram.Time: Ansys.Core.Units.Quantity | None
Gets the Time.
- property EquivalentRadiatedPowerWaterfallDiagram.DisplayTime: Ansys.Core.Units.Quantity | None
Gets or sets the DisplayTime.
- property EquivalentRadiatedPowerWaterfallDiagram.GraphControlsXAxis: Ansys.Mechanical.DataModel.Enums.GraphControlsXAxis | None
Gets or sets the GraphControlsXAxis.
- property EquivalentRadiatedPowerWaterfallDiagram.DisplayOption: Ansys.Mechanical.DataModel.Enums.ResultAveragingType | None
Gets or sets the DisplayOption.
- property EquivalentRadiatedPowerWaterfallDiagram.DpfEvaluation: Ansys.Mechanical.DataModel.Enums.DpfEvaluationType | None
Gets or sets the DpfEvaluation.
- property EquivalentRadiatedPowerWaterfallDiagram.By: Ansys.Mechanical.DataModel.Enums.SetDriverStyle | None
Gets or sets the By.
- property EquivalentRadiatedPowerWaterfallDiagram.ItemType: Ansys.Mechanical.DataModel.Enums.ResultFileItemType | None
Gets or sets the ItemType.
- property EquivalentRadiatedPowerWaterfallDiagram.CalculateTimeHistory: System.Boolean | None
Gets or sets the CalculateTimeHistory.
- property EquivalentRadiatedPowerWaterfallDiagram.Suppressed: System.Boolean | None
Gets or sets the Suppressed.
- property EquivalentRadiatedPowerWaterfallDiagram.Children: System.Collections.Generic.IList[Ansys.Mechanical.DataModel.Interfaces.IDataModelObject] | None
Gets the list of children.
- property EquivalentRadiatedPowerWaterfallDiagram.Comments: System.Collections.Generic.IEnumerable[Ansys.ACT.Automation.Mechanical.Comment] | None
Gets the list of associated comments.
- property EquivalentRadiatedPowerWaterfallDiagram.Figures: System.Collections.Generic.IEnumerable[Ansys.ACT.Automation.Mechanical.Figure] | None
Gets the list of associated figures.
- property EquivalentRadiatedPowerWaterfallDiagram.Images: System.Collections.Generic.IEnumerable[Ansys.ACT.Automation.Mechanical.Image] | None
Gets the list of associated images.
- property EquivalentRadiatedPowerWaterfallDiagram.InternalObject: System.Object | None
Gets the internal object. For advanced usage only.
- property EquivalentRadiatedPowerWaterfallDiagram.Properties: System.Collections.Generic.IReadOnlyList[Ansys.ACT.Automation.Mechanical.Property] | None
Gets the list of properties for this object.
- property EquivalentRadiatedPowerWaterfallDiagram.VisibleProperties: System.Collections.Generic.IReadOnlyList[Ansys.ACT.Automation.Mechanical.Property] | None
Gets the list of properties that are visible for this object.
Method detail#
- EquivalentRadiatedPowerWaterfallDiagram.ClearGeneratedData() System.Void
Run the ClearGeneratedData action.
- EquivalentRadiatedPowerWaterfallDiagram.EvaluateAllResults() System.Void
Run the EvaluateAllResults action.
- EquivalentRadiatedPowerWaterfallDiagram.FetchRemoteResults() System.Void
Run the FetchRemoteResult action.
- EquivalentRadiatedPowerWaterfallDiagram.ExportToTextFile(filePath: System.String) System.Void
Run the ExportToTextFile action.
- EquivalentRadiatedPowerWaterfallDiagram.ExportAnimation(filePath: System.String, format: Ansys.Mechanical.DataModel.Enums.GraphicsAnimationExportFormat, settings: Ansys.Mechanical.Graphics.AnimationExportSettings) System.Void
Run the ExportAnimation action.
- EquivalentRadiatedPowerWaterfallDiagram.DuplicateWithoutResults() Ansys.Mechanical.DataModel.Interfaces.IDataModelObject
Run the DuplicateWithoutResults action.
- EquivalentRadiatedPowerWaterfallDiagram.CreateResultsAtAllSets() System.Collections.Generic.List[Ansys.Mechanical.DataModel.Interfaces.IDataModelObject]
Creates results at all sets for results under a solution.
- EquivalentRadiatedPowerWaterfallDiagram.PromoteToNamedSelection() System.Collections.Generic.IEnumerable[Ansys.ACT.Automation.Mechanical.NamedSelection]
Run the PromoteToNamedSelection action.
- EquivalentRadiatedPowerWaterfallDiagram.CreateParameter(propName: System.String) Ansys.ACT.Interfaces.Mechanical.IParameter
CreateParameter method.
- EquivalentRadiatedPowerWaterfallDiagram.AddAlert() Ansys.ACT.Automation.Mechanical.Results.Alert
Creates a new Alert
- EquivalentRadiatedPowerWaterfallDiagram.AddConvergence() Ansys.ACT.Automation.Mechanical.Results.Convergence
Creates a new Convergence
- EquivalentRadiatedPowerWaterfallDiagram.RenameBasedOnDefinition() System.Void
Run the RenameBasedOnDefinition action.
- EquivalentRadiatedPowerWaterfallDiagram.Delete() System.Void
Run the Delete action.
- EquivalentRadiatedPowerWaterfallDiagram.GetChildren(recurses: System.Boolean, children: System.Collections.Generic.IList[ChildrenType]) System.Collections.Generic.IList[ChildrenType]
Gets the list of children, filtered by type.
- EquivalentRadiatedPowerWaterfallDiagram.GetChildren(category: Ansys.Mechanical.DataModel.Enums.DataModelObjectCategory, recurses: System.Boolean, children: System.Collections.Generic.IList[Ansys.Mechanical.DataModel.Interfaces.IDataModelObject]) System.Collections.Generic.IList[Ansys.Mechanical.DataModel.Interfaces.IDataModelObject]
Gets the list of children, filtered by type.
- EquivalentRadiatedPowerWaterfallDiagram.AddComment() Ansys.ACT.Automation.Mechanical.Comment
Creates a new child Comment.
- EquivalentRadiatedPowerWaterfallDiagram.AddFigure() Ansys.ACT.Automation.Mechanical.Figure
Creates a new child Figure.
- EquivalentRadiatedPowerWaterfallDiagram.AddImage(filePath: System.String) Ansys.ACT.Automation.Mechanical.Image
Creates a new child Image.
If a filePath is provided, the image will be loaded from that file,
if not, the image will be a screen capture of the Geometry window.
- EquivalentRadiatedPowerWaterfallDiagram.Activate() System.Void
Activate the current object.
- EquivalentRadiatedPowerWaterfallDiagram.CopyTo(other: Ansys.ACT.Automation.Mechanical.DataModelObject) System.Void
Copies all visible properties from this object to another.
- EquivalentRadiatedPowerWaterfallDiagram.Duplicate() Ansys.Mechanical.DataModel.Interfaces.IDataModelObject
Creates a copy of the current DataModelObject.
- EquivalentRadiatedPowerWaterfallDiagram.GroupAllSimilarChildren() System.Void
Run the GroupAllSimilarChildren action.
- EquivalentRadiatedPowerWaterfallDiagram.GroupSimilarObjects() Ansys.ACT.Automation.Mechanical.TreeGroupingFolder
Run the GroupSimilarObjects action.
- EquivalentRadiatedPowerWaterfallDiagram.PropertyByName(name: System.String) Ansys.ACT.Automation.Mechanical.Property
Get a property by its unique name.
- EquivalentRadiatedPowerWaterfallDiagram.PropertyByAPIName(name: System.String) Ansys.ACT.Automation.Mechanical.Property
Get a property by its API name.
If multiple properties have the same API Name, only the first property with that name will be returned.
- EquivalentRadiatedPowerWaterfallDiagram.GetParameter(propName: System.String) Ansys.ACT.Interfaces.Mechanical.IParameter
Gets the parameter corresponding to the given property.
- EquivalentRadiatedPowerWaterfallDiagram.RemoveParameter(propName: System.String) System.Void
Removes the parameter from the parameter set corresponding to the given property.