ANSYSAnalysisSettings#

class ansys.mechanical.stubs.v242.Ansys.ACT.Automation.Mechanical.AnalysisSettings.ANSYSAnalysisSettings#

Bases: object

Defines a ANSYSAnalysisSettings.

Overview#

GetStepEndTime

Gets the Step End Time at a given solution step.

SetStepEndTime

Sets the Step End Time for a given solution step.

GetAutomaticTimeStepping

Gets the Automatic Time Stepping at a given solution step.

SetAutomaticTimeStepping

Sets the Automatic Time Stepping for a given solution step.

GetForceConvergenceType

Gets the Force Convergence Tolerance Type at a given solution step.

SetForceConvergenceType

Sets the Force Convergence Tolerance Type for a given solution step.

GetForceConvergenceTolerance

Gets the Force Convergence Tolerance as a percentage at a given solution step.

SetForceConvergenceTolerance

Sets the Force Convergence Tolerance as a percentage for a given solution step.

GetForceConvergenceValue

Gets the Force Convergence Value at a given solution step.

SetForceConvergenceValue

Sets the Force Convergence Value for a given solution step.

GetForceConvergenceMinimumReference

Gets the Force Convergence Minimum Reference at a given solution step.

SetForceConvergenceMinimumReference

Sets the Force Convergence Minimum Reference for a given solution step.

GetMomentConvergenceType

Gets the Moment Convergence Tolerance type at a given solution step.

SetMomentConvergenceType

Sets the Moment Convergence Tolerance type for a given solution step.

GetMomentConvergenceTolerance

Gets the Moment Convergence Tolerance as a percentage at a given solution step.

SetMomentConvergenceTolerance

Sets the Moment Convergence Tolerance as a percentage for a given solution step.

GetMomentConvergenceValue

Gets the Moment Convergence Value at a given solution step.

SetMomentConvergenceValue

Sets the Moment Convergence Value for a given solution step.

GetMomentConvergenceMinimumReference

Gets the Moment Convergence Minimum Reference at a given solution step.

SetMomentConvergenceMinimumReference

Sets the Moment Convergence Minimum Reference for a given solution step.

GetDisplacementConvergenceType

Gets the Displacement Convergence Tolerance type at a given solution step.

SetDisplacementConvergenceType

Sets the Displacement Convergence Tolerance type for a given solution step.

GetDisplacementConvergenceTolerance

Gets the Displacement Convergence Tolerance as a percentage at a given solution step.

SetDisplacementConvergenceTolerance

Sets the Displacement Convergence Tolerance as a percentage for a given solution step.

GetDisplacementConvergenceValue

Gets the Displacement Convergence Value at a given solution step.

SetDisplacementConvergenceValue

Sets the Displacement Convergence Value for a given solution step.

GetDisplacementConvergenceMinimumReference

Gets the Displacement Convergence Minimum Reference at a given solution step.

SetDisplacementConvergenceMinimumReference

Sets the Displacement Convergence Minimum Reference for a given solution step.

GetRotationConvergenceType

Gets the Rotation Convergence Tolerance type at a given solution step.

SetRotationConvergenceType

Sets the Rotation Convergence Tolerance type for a given solution step.

GetRotationConvergenceTolerance

Gets the Rotation Convergence Tolerance as a percentage at a given solution step.

SetRotationConvergenceTolerance

Sets the Rotation Convergence Tolerance as a percentage for a given solution step.

GetRotationConvergenceValue

Gets the Rotation Convergence Value at a given solution step.

SetRotationConvergenceValue

Sets the Rotation Convergence Value for a given solution step.

GetRotationConvergenceMinimumReference

Gets the Rotation Convergence Minimum Reference at a given solution step.

SetRotationConvergenceMinimumReference

Sets the Rotation Convergence Minimum Reference for a given solution step.

SetTemperatureConvergenceType

Sets the Temperature Convergence Tolerance type for a given solution step.

SetTemperatureConvergenceTolerance

Sets the Temperature Convergence Tolerance as a percentage for a given solution step.

SetTemperatureConvergenceValue

Sets the Temperature Convergence Value for a given solution step.

SetTemperatureConvergenceInputValue

Sets the Temperature Convergence Input Value for a given solution step.

SetTemperatureConvergenceMinimumReference

Sets the Temperature Convergence Minimum Reference for a given solution step.

SetHeatConvergenceType

Sets the Heat Convergence Tolerance type for a given solution step.

SetHeatConvergenceTolerance

Sets the Heat Convergence Tolerance as a percentage for a given solution step.

SetHeatConvergenceValue

Sets the Heat Convergence Value for a given solution step.

SetHeatConvergenceMinimumReference

Sets the Heat Convergence Minimum Reference for a given solution step.

SetVoltageConvergenceType

Sets the Voltage Convergence Tolerance type for a given solution step.

SetVoltageConvergenceTolerance

Sets the Voltage Convergence Tolerance as a percentage for a given solution step.

SetVoltageConvergenceValue

Sets the Voltage Convergence Value for a given solution step.

SetVoltageConvergenceMinimumReference

Sets the Voltage Convergence Minimum Reference for a given solution step.

SetChargeConvergenceType

Sets the Charge Convergence Tolerance type for a given solution step.

SetChargeConvergenceTolerance

Sets the Charge Convergence Tolerance as a percentage for a given solution step.

SetChargeConvergenceValue

Sets the Charge Convergence Value for a given solution step.

SetChargeConvergenceMinimumReference

Sets the Charge Convergence Minimum Reference for a given solution step.

SetEnergyConvergenceType

Sets the Energy Convergence Tolerance type for a given solution step.

SetEnergyConvergenceTolerance

Sets the Energy Convergence Tolerance as a percentage for a given solution step.

SetEnergyConvergenceValue

Sets the Energy Convergence Value for a given solution step.

SetEnergyConvergenceMinimumReference

Sets the Energy Convergence Minimum Reference for a given solution step.

SetCurrentConvergenceType

Sets the Current Convergence Tolerance type for a given solution step.

SetCurrentConvergenceTolerance

Sets the Current Convergence Tolerance as a percentage for a given solution step.

SetCurrentConvergenceValue

Sets the Current Convergence Value for a given solution step.

SetCurrentConvergenceMinimumReference

Sets the Current Convergence Minimum Reference for a given solution step.

SetEmagAMPSConvergenceType

Sets the EmagAMPS Convergence Tolerance type for a given solution step.

SetEmagAMPSConvergenceTolerance

Sets the EmagAMPS Convergence Tolerance as a percentage for a given solution step.

SetEmagAMPSConvergenceValue

Sets the EmagAMPS Convergence Value for a given solution step.

SetEmagAMPSConvergenceMinimumReference

Sets the EmagAMPS Convergence Minimum Reference for a given solution step.

SetEmagCSGConvergenceType

Sets the EmagCSG Convergence Tolerance type for a given solution step.

SetEmagCSGConvergenceTolerance

Sets the EmagCSG Convergence Tolerance as a percentage for a given solution step.

SetEmagCSGConvergenceValue

Sets the EmagCSG Convergence Value for a given solution step.

SetEmagCSGConvergenceMinimumReference

Sets the EmagCSG Convergence Minimum Reference for a given solution step.

GetTemperatureConvergenceType

Gets the Temperature Convergence Tolerance type at a given solution step.

GetTemperatureConvergenceTolerance

Gets the Temperature Convergence Tolerance as a percentage at a given solution step.

GetTemperatureConvergenceValue

Gets the Temperature Convergence Value at a given solution step.

GetTemperatureConvergenceInputValue

Gets the Temperature Convergence Input Value at a given solution step.

GetTemperatureConvergenceMinimumReference

Gets the Temperature Convergence Minimum Reference at a given solution step.

GetHeatConvergenceType

Gets the Heat Convergence Tolerance type at a given solution step.

GetHeatConvergenceTolerance

Gets the Heat Convergence Tolerance as a percentage at a given solution step.

GetHeatConvergenceValue

Gets the Heat Convergence Value at a given solution step.

GetHeatConvergenceMinimumReference

Gets the Heat Convergence Minimum Reference at a given solution step.

GetVoltageConvergenceType

Gets the Voltage Convergence Tolerance type at a given solution step.

GetVoltageConvergenceTolerance

Gets the Voltage Convergence Tolerance as a percentage at a given solution step.

GetVoltageConvergenceValue

Gets the Voltage Convergence Value at a given solution step.

GetVoltageConvergenceMinimumReference

Gets the Voltage Convergence Minimum Reference at a given solution step.

GetCurrentConvergenceType

Gets the Current Convergence Tolerance type at a given solution step.

GetCurrentConvergenceTolerance

Gets the Current Convergence Tolerance as a percentage at a given solution step.

GetCurrentConvergenceValue

Gets the Current Convergence Value at a given solution step.

GetCurrentConvergenceMinimumReference

Gets the Current Convergence Minimum Reference at a given solution step.

GetEmagAMPSConvergenceType

Gets the EmagAMPS Convergence Tolerance type at a given solution step.

GetEmagAMPSConvergenceTolerance

Gets the EmagAMPS Convergence Tolerance as a percentage at a given solution step.

GetEmagAMPSConvergenceValue

Gets the EmagAMPS Convergence Value at a given solution step.

GetEmagAMPSConvergenceMinimumReference

Gets the EmagAMPS Convergence Minimum Reference at a given solution step.

GetEmagCSGConvergenceType

Gets the EmagCSG Convergence Tolerance type at a given solution step.

GetEmagCSGConvergenceTolerance

Gets the EmagCSG Convergence Tolerance as a percentage at a given solution step.

GetEmagCSGConvergenceValue

Gets the EmagCSG Convergence Value at a given solution step.

GetEmagCSGConvergenceMinimumReference

Gets the EmagCSG Convergence Minimum Reference at a given solution step.

GetEnergyConvergenceType

Gets the Energy Convergence Tolerance type at a given solution step.

GetEnergyConvergenceTolerance

Gets the Energy Convergence Tolerance as a percentage at a given solution step.

GetEnergyConvergenceValue

Gets the Energy Convergence Value at a given solution step.

GetEnergyConvergenceMinimumReference

Gets the Energy Convergence Minimum Reference at a given solution step.

GetLineSearch

Gets the Line Search at a given solution step.

SetLineSearch

Sets the Line Search for a given solution step.

GetStabilization

Gets the Stabilization at a given solution step.

SetStabilization

Sets the Stabilization for a given solution step.

GetStabilizationMethod

Gets the Stabilization Method at a given solution step.

SetStabilizationMethod

Sets the Stabilization Method for a given solution step.

GetStabilizationEnergyDissipationRatio

Gets the Stabilization Energy Dissipation Ratio at a given solution step.

SetStabilizationEnergyDissipationRatio

Sets the Stabilization Energy Dissipation Ratio for a given solution step.

GetStabilizationDampingFactor

Gets the Stabilization Damping Factor at a given solution step.

SetStabilizationDampingFactor

Sets the Stabilization Damping Factor for a given solution step.

GetStabilizationFirstSubstepOption

Gets the Stabilization First Substep Option at a given solution step.

SetStabilizationFirstSubstepOption

Sets the Stabilization First Substep Option for a given solution step.

GetStabilizationForceLimit

Gets the Stabilization Force Limit at a given solution step.

SetStabilizationForceLimit

Sets the Stabilization Force Limit for a given solution step.

GetStoreResultsAt

Gets the Store Results At at a given solution step.

SetStoreResultsAt

Sets the Store Results At for a given solution step.

GetStoreResulsAtValue

Gets the Store Results At Value at a given solution step.

SetStoreResulsAtValue

Sets the Store Results At Value for a given solution step.

GetDefineBy

Gets the Define By at a given solution step.

SetDefineBy

Sets the Define By for a given solution step.

GetCarryOverTimeStep

Gets the Carry Over Time Step at a given solution step.

SetCarryOverTimeStep

Sets the Carry Over Time Step for a given solution step.

GetInitialTimeStep

Gets the Initial Time Step at a given solution step.

SetInitialTimeStep

Sets the Initial Time Step for a given solution step.

GetMinimumTimeStep

Gets the Minimum Time Step at a given solution step.

SetMinimumTimeStep

Sets the Minimum Time Step for a given solution step.

GetMaximumTimeStep

Gets the Maximum Time Step at a given solution step.

SetMaximumTimeStep

Sets the Maximum Time Step for a given solution step.

GetInitialSubsteps

Gets the Initial Substeps at a given solution step.

SetInitialSubsteps

Sets the Initial Substeps for a given solution step.

GetMinimumSubsteps

Gets the Minimum Substeps at a given solution step.

SetMinimumSubsteps

Sets the Minimum Substeps for a given solution step.

GetMaximumSubsteps

Gets the Maximum Substeps at a given solution step.

SetMaximumSubsteps

Sets the Maximum Substeps for a given solution step.

SetNumberOfSubSteps

Sets the Number of Substeps for a given solution step.

GetNumberOfSubSteps

Gets the Number of Substeps for a given solution step.

SetTimeStep

Sets the Time Step for a given solution step.

GetTimeStep

Sets the Time Step for a given solution step.

SetTimeIntegration

Sets the TimeIntegration for a given solution step.

SetStructuralOnly

Sets the TimeIntegration Structural for a given solution step.

SetThermalOnly

Sets the TimeIntegration Thermal for a given solution step.

GetTimeIntegration

Gets the TimeIntegration for a given solution step.

GetStructuralOnly

Gets the TimeIntegration Structural for a given solution step.

GetThermalOnly

Sets the TimeIntegration Thermal for a given solution step.

GetStepName

Gets the Step name at a given step.

SetStepName

Sets the Step name at a given step.

GetAMStepType

Gets the AM Process Step Type at a given step.

CopyTo

CopyTo method.

SetCreepEffects

Sets the Creep Effects for a given solution step.

GetCreepEffects

Gets the Creep Effects for a given solution step.

SetCreepLimitRatio

Sets the Creep Limit Ratio for a given solution step.

GetCreepLimitRatio

Gets the Creep Limit Ratio for a given solution step.

DeleteAllRestartPoints

DeleteAllRestartPoints method.

GetChildren

Gets the list of children, filtered by type.

GetChildren

Gets the list of children, filtered by type.

AddComment

Creates a new child Comment.

AddFigure

Creates a new child Figure.

AddImage

Creates a new child Image.

Activate

Activate the current object.

Duplicate

Creates a copy of the current DataModelObject.

GroupAllSimilarChildren

Run the GroupAllSimilarChildren action.

GroupSimilarObjects

Run the GroupSimilarObjects action.

PropertyByName

Get a property by its unique name.

PropertyByAPIName

Get a property by its API name.

CreateParameter

Creates a new parameter for a Property.

GetParameter

Gets the parameter corresponding to the given property.

RemoveParameter

Removes the parameter from the parameter set corresponding to the given property.

StepName

Gets or sets the Step Name.

AMStepType

Gets or sets the AM Process Step Type.

AMSubstepsToApplyHeats

Gets or sets the AM Substeps to Apply Heat.

AMSubstepsBetweenHeating

Gets or sets the AM Substeps Between Heating.

AMCooldownNumberOfSubsteps

Gets or sets the AM Cooldown Number of Substeps.

CooldownTimeType

Gets or sets the AM Cooldown Time Type.

CooldownTime

Gets or sets the AM Cooldown Time.

LayersToBuild

Gets or sets the AM Layers to Build.

ReferenceTemperatureType

Gets or sets the AM Reference Temperature Type.

ReferenceTemperature

Gets or sets the AM Reference Temperature.

RelaxationTemperatureType

Gets or sets the AM Relaxation Temperature Type.

NumberOfRestartPoints

Gets Number of Restart Points.

CurrentRestartPoint

Gets or sets the Current Restart Point.

AggressiveRemeshing

Gets or sets the AggressiveRemeshing.

SpinSoftening

Gets or sets the SpinSoftening.

UserDefinedFrequencySteps

Gets or sets the UserDefinedFrequencySteps.

OutputSelection

Gets or sets the Output Selection property in the Output Controls group of Analysis Settings.

NamedSelection

Gets or sets the objects of type NamedSelection to – Named Selection property in the Output Controls group of Analysis Settings.

InternalObject

Gets the internal object. For advanced usage only.

MassCoefficient

Gets or sets the MassCoefficient.

StiffnessCoefficient

Gets or sets the StiffnessCoefficient.

DampingRatio

Gets or sets the DampingRatio.

ConstantDampingRatio

Gets or sets the ConstantDampingRatio.

StructuralDampingCoefficient

Gets or sets the StructuralDampingCoefficient.

ContactSplitMaxNum

Gets or sets the ContactSplitMaxNum.

ChargeConvergenceTolerance

Gets or sets the ChargeConvergenceTolerance.

CurrentConvergenceTolerance

Gets or sets the CurrentConvergenceTolerance.

EmagAMPSConvergenceTolerance

Gets or sets the EmagAMPSConvergenceTolerance.

EmagCSGConvergenceTolerance

Gets or sets the EmagCSGConvergenceTolerance.

EnergyConvergenceTolerance

Gets or sets the EnergyConvergenceTolerance.

HeatConvergenceTolerance

Gets or sets the HeatConvergenceTolerance.

TemperatureConvergenceTolerance

Gets or sets the TemperatureConvergenceTolerance.

VoltageConvergenceTolerance

Gets or sets the VoltageConvergenceTolerance.

CreepLimitRatio

Gets or sets the CreepLimitRatio.

CurrentStepNumberHarmonic

Gets or sets the CurrentStepNumberHarmonic.

CurrentStepNumber

Gets or sets the CurrentStepNumber.

EngineOrderofExcitation

Gets or sets the EngineOrderofExcitation.

MaximumHarmonicIndex

Gets or sets the MaximumHarmonicIndex.

MinimumHarmonicIndex

Gets or sets the MinimumHarmonicIndex.

HarmonicIndexInterval

Gets or sets the HarmonicIndexInterval.

ClusterNumber

Gets or sets the ClusterNumber.

SolutionIntervals

Gets or sets the SolutionIntervals.

KrylovSubspaceDimension

Gets or sets the KrylovSubspaceDimension.

KrylovResidualTolerance

Gets or sets the KrylovResidualTolerance.

HarmonicOrders

Gets or sets the HarmonicOrders.

InitialSubsteps

Gets or sets the InitialSubsteps.

InverseOptionEndStep

Gets or sets the InverseOptionEndStep.

MaximumSubsteps

Gets or sets the MaximumSubsteps.

MeshLoadStepValue

Gets or sets the MeshLoadStepValue.

MinimumSubsteps

Gets or sets the MinimumSubsteps.

ModalNumberOfPoints

Gets or sets the ModalNumberOfPoints.

ModeSignificanceLevel

Gets or sets the ModeSignificanceLevel.

GlobalSizeRatioQualityImprovement

Gets or sets the GlobalSizeRatioQualityImprovement.

GlobalSizeRatioQualityRefinement

Gets or sets the GlobalSizeRatioQualityRefinement.

NumberOfSculptedLayersQualityImprovement

Gets or sets the NumberOfSculptedLayersQualityImprovement.

NumberOfSculptedLayersRefinement

Gets or sets the NumberOfSculptedLayersRefinement.

RemeshingToleranceQualityImprovement

Gets or sets the RemeshingToleranceQualityImprovement.

RemeshingToleranceRefinement

Gets or sets the RemeshingToleranceRefinement.

StoreResulsAtValue

Gets or sets the StoreResulsAtValue.

NumberOfModesToUse

Gets or sets the NumberOfModesToUse.

NumberOfRPMs

Gets or sets the NumberOfRPMs.

NumberOfSteps

Gets or sets the NumberOfSteps.

NumberOfSubSteps

Gets or sets the NumberOfSubSteps.

NumericalDampingValue

Gets or sets the NumericalDampingValue.

NumLoadVectors

Gets or sets the NumLoadVectors.

MaximumModesToFind

Gets or sets the MaximumModesToFind.

NumberOfZones

Gets or sets the NumberOfZones.

AxisymmetryDivisions

Gets or sets the AxisymmetryDivisions.

HemicubeResolution

Gets or sets the HemicubeResolution.

FluxConvergence

Gets or sets the FluxConvergence.

MaximumIteration

Gets or sets the MaximumIteration.

OverRelaxation

Gets or sets the OverRelaxation.

ReformulationTolerance

Gets or sets the ReformulationTolerance.

RestartAtLoadStep

Gets the RestartAtLoadStep.

RestartAtSubstep

Gets the RestartAtSubstep.

RestartAtTime

Gets the RestartAtTime.

RpmClusterNumber

Gets or sets the RpmClusterNumber.

RpmSolutionIntervals

Gets or sets the RpmSolutionIntervals.

MaximumPointsToSavePerStep

Gets or sets the MaximumPointsToSavePerStep.

SaveSpecifiedLoadStep

Gets or sets the SaveSpecifiedLoadStep.

LoadStepValue

Gets or sets the LoadStepValue.

SignificanceThreshold

Gets or sets the SignificanceThreshold.

StabilizationDampingFactor

Gets or sets the StabilizationDampingFactor.

StabilizationEnergyDissipationRatio

Gets or sets the StabilizationEnergyDissipationRatio.

StabilizationForceLimit

Gets or sets the StabilizationForceLimit.

TransientApplicationUserDefined

Gets or sets the TransientApplicationUserDefined.

SpringStiffnessFactor

Gets or sets the SpringStiffnessFactor.

RelaxationTemperature

Gets or sets the RelaxationTemperature.

Frequency

Gets or sets the Frequency.

CentralFrequency

Gets or sets the CentralFrequency.

ChargeConvergenceMinimumReference

Gets or sets the ChargeConvergenceMinimumReference.

ChargeConvergenceValue

Gets or sets the ChargeConvergenceValue.

CurrentConvergenceMinimumReference

Gets or sets the CurrentConvergenceMinimumReference.

CurrentConvergenceValue

Gets or sets the CurrentConvergenceValue.

DisplacementConvergenceMinimumReference

Gets or sets the DisplacementConvergenceMinimumReference.

DisplacementConvergenceTolerance

Gets or sets the DisplacementConvergenceTolerance.

DisplacementConvergenceValue

Gets or sets the DisplacementConvergenceValue.

EmagAMPSConvergenceMinimumReference

Gets or sets the EmagAMPSConvergenceMinimumReference.

EmagAMPSConvergenceValue

Gets or sets the EmagAMPSConvergenceValue.

EmagCSGConvergenceMinimumReference

Gets or sets the EmagCSGConvergenceMinimumReference.

EmagCSGConvergenceValue

Gets or sets the EmagCSGConvergenceValue.

EnergyConvergenceMinimumReference

Gets or sets the EnergyConvergenceMinimumReference.

EnergyConvergenceValue

Gets or sets the EnergyConvergenceValue.

ForceConvergenceMinimumReference

Gets or sets the ForceConvergenceMinimumReference.

ForceConvergenceTolerance

Gets or sets the ForceConvergenceTolerance.

ForceConvergenceValue

Gets or sets the ForceConvergenceValue.

HeatConvergenceMinimumReference

Gets or sets the HeatConvergenceMinimumReference.

HeatConvergenceValue

Gets or sets the HeatConvergenceValue.

MomentConvergenceMinimumReference

Gets or sets the MomentConvergenceMinimumReference.

MomentConvergenceTolerance

Gets or sets the MomentConvergenceTolerance.

MomentConvergenceValue

Gets or sets the MomentConvergenceValue.

RotationConvergenceMinimumReference

Gets or sets the RotationConvergenceMinimumReference.

RotationConvergenceTolerance

Gets or sets the RotationConvergenceTolerance.

TemperatureConvergenceMinimumReference

Gets or sets the TemperatureConvergenceMinimumReference.

TemperatureConvergenceInputValue

Gets or sets the TemperatureConvergenceInputValue.

VoltageConvergenceMinimumReference

Gets or sets the VoltageConvergenceMinimumReference.

VoltageConvergenceValue

Gets or sets the VoltageConvergenceValue.

RemovalDirection

Gets or sets the RemovalDirection.

RemovalStepSize

Gets or sets the RemovalStepSize.

StepEndTime

Gets or sets the StepEndTime.

MinimumElementSize

Gets or sets the Minimum Element Size property for Geometry Based Adaptivity.

RangeMaximum

Gets or sets the Range Maximum property in Options group of Analysis Settings in Harmonic Analysis.

RangeMinimum

Gets or sets the Range Minimum property in Options group of Analysis Settings in Harmonic Analysis.

KrylovSubspaceFrequency

Gets or sets the KrylovSubspaceFrequency.

ModalRangeMaximum

Gets or sets the ModalRangeMaximum.

ModalRangeMinimum

Gets or sets the ModalRangeMinimum.

InitialTimeStep

Gets or sets the InitialTimeStep.

SearchRangeMaximum

Gets or sets the Range Maximum property in Options group of Analysis Settings in Modal Analysis.

MaximumTimeStep

Gets or sets the MaximumTimeStep.

SearchRangeMinimum

Gets or sets the Range Minimum property in Options group of Analysis Settings in Modal Analysis.

MinimumTimeStep

Gets or sets the MinimumTimeStep.

BoundaryAngle

Gets or sets the BoundaryAngle.

EdgeSplittingAngle

Gets or sets the EdgeSplittingAngle.

SolverTolerance

Gets or sets the SolverTolerance.

RpmValue

Gets or sets the RpmValue.

RpmCentralFrequency

Gets or sets the RpmCentralFrequency.

RpmRangeMaximum

Gets or sets the RpmRangeMaximum.

RpmRangeMinimum

Gets or sets the RpmRangeMinimum.

TimeStep

Gets or sets the TimeStep.

SpringStiffnessValue

Gets or sets the SpringStiffnessValue.

BaseRemovalType

Gets or sets the BaseRemovalType.

StiffnessCoefficientDefineBy

Gets or sets the StiffnessCoefficientDefineBy.

CacheResultsInMemory

Gets or sets the CacheResultsInMemory.

ParticipationFactor

Gets or sets the ParticipationFactor.

StoreResultsAt

Gets or sets the StoreResultsAt.

ConstantDamping

Gets or sets the ConstantDamping.

ContactSplit

Gets or sets the ContactSplit.

ContactSummary

Gets or sets the ContactSummary.

ChargeConvergence

Gets or sets the ChargeConvergence.

CurrentConvergence

Gets or sets the CurrentConvergence.

DisplacementConvergence

Gets or sets the DisplacementConvergence.

AMPSConvergence

Gets or sets the AMPSConvergence.

CSGConvergence

Gets or sets the CSGConvergence.

EnergyConvergence

Gets or sets the EnergyConvergence.

ForceConvergence

Gets or sets the ForceConvergence.

HeatConvergence

Gets or sets the HeatConvergence.

MomentConvergence

Gets or sets the MomentConvergence.

RotationConvergence

Gets or sets the RotationConvergence.

TemperatureConvergence

Gets or sets the TemperatureConvergence.

TemperatureConvergenceValue

Gets or sets the TemperatureConvergenceValue.

VoltageConvergence

Gets or sets the VoltageConvergence.

CoriolisEffectApplied

Gets or sets the CoriolisEffectApplied.

CreepEffects

Gets or sets the CreepEffects.

HarmonicIndexRange

Gets or sets the HarmonicIndexRange.

DampingDefineBy

Gets or sets the DampingDefineBy.

FarFieldRadiationSurface

Gets or sets the FarFieldRadiationSurface.

ExpandResultsFrom

Gets or sets the ExpandResultsFrom.

FrequencySpacing

Gets or sets the FrequencySpacing.

FutureAnalysis

Gets or sets the FutureAnalysis.

GeneralMiscellaneousOption

Gets or sets the GeneralMiscellaneousOption.

MultistepType

Gets or sets the MultistepType.

ModalFrequencyRange

Gets or sets the ModalFrequencyRange.

StoreResultsAtAllFrequencies

Gets or sets the StoreResultsAtAllFrequencies.

SolutionMethod

Gets or sets the SolutionMethod.

IncludeNegativeLoadMultiplier

Gets or sets the IncludeNegativeLoadMultiplier.

LineSearch

Gets or sets the LineSearch.

GenerateMeshRestartPoints

Gets or sets the GenerateMeshRestartPoints.

MeshRetainFilesAfterFullSolve

Gets or sets the MeshRetainFilesAfterFullSolve.

MeshSaveAtLoadStep

Gets or sets the MeshSaveAtLoadStep.

MeshSaveAtSubstep

Gets or sets the MeshSaveAtSubstep.

ModeReuse

Gets or sets the ModeReuse.

ModesCombinationType

Gets or sets the ModesCombinationType.

ModeSelectionMethod

Gets or sets the ModeSelectionMethod.

OnDemandExpansionOption

Gets or sets the OnDemandExpansionOption.

NewtonRaphsonOption

Gets or sets the NewtonRaphsonOption.

NodalForces

Gets or sets the NodalForces.

ProjectToGeometry

Gets or sets the ProjectToGeometry.

RefinementAlgorithm

Gets or sets the RefinementAlgorithm.

RemeshingGradient

Gets or sets the RemeshingGradient.

NonLinearFormulation

Gets or sets the NonLinearFormulation.

NumericalDamping

Gets or sets the NumericalDamping.

Expansion

Gets the Expansion.

ViewFactorMethod

Gets or sets the ViewFactorMethod.

RadiositySolver

Gets or sets the RadiositySolver.

CombineRestartFiles

Gets or sets the CombineRestartFiles.

GenerateRestartPoints

Gets or sets the GenerateRestartPoints.

RetainFilesAfterFullSolve

Gets or sets the RetainFilesAfterFullSolve.

RestartType

Gets or sets the RestartType.

ResultFileCompression

Gets or sets the ResultFileCompression.

RpmFrequencySpacing

Gets or sets the RpmFrequencySpacing.

SaveAtLoadStep

Gets or sets the SaveAtLoadStep.

SaveAtSubstep

Gets or sets the SaveAtSubstep.

ScatteredFieldFormulation

Gets or sets the ScatteredFieldFormulation.

ScatteringOutputType

Gets or sets the ScatteringOutputType.

SolverUnitSystem

Gets or sets the SolverUnitSystem.

SolverPivotChecking

Gets or sets the SolverPivotChecking.

SolverType

Gets or sets the SolverType.

SolverUnits

Gets or sets the SolverUnits.

SpectrumType

Gets or sets the SpectrumType.

Stabilization

Gets or sets the Stabilization.

StabilizationActivationForFirstSubstep

Gets or sets the StabilizationActivationForFirstSubstep.

StabilizationMethod

Gets or sets the StabilizationMethod.

StoreModalResults

Gets or sets the StoreModalResults.

DefineBy

Gets or sets the DefineBy.

TransientApplication

Gets or sets the TransientApplication.

UpdateViewFactor

Gets or sets the specification for updating the view factor.

AutomaticTimeStepping

Gets or sets the AutomaticTimeStepping.

RetainModesymFileAfterSolve

Gets or sets the RetainModesymFileAfterSolve.

WeakSprings

Gets or sets the WeakSprings.

SpringStiffness

Gets or sets the SpringStiffness.

IgnoreAcousticDamping

Gets or sets the IgnoreAcousticDamping.

CalculateAcceleration

Gets or sets the CalculateAcceleration.

BackStress

Gets or sets the BackStress.

ContactMiscellaneous

Gets or sets the ContactMiscellaneous.

CStarIntegral

Gets or sets the CStarIntegral.

ElementCurrentDensity

Gets or sets the ElementCurrentDensity.

FieldIntensityandFluxDensity

Gets or sets the FieldIntensityandFluxDensity.

ElectromagneticNodalForces

Gets or sets the ElectromagneticNodalForces.

ContactData

Gets or sets the ContactData.

CalculateVolumeEnergy

Gets or sets the CalculateVolumeEnergy.

NonlinearData

Gets or sets the NonlinearData.

CalculateEnergy

Gets or sets the CalculateEnergy.

CalculateEulerAngles

Gets or sets the CalculateEulerAngles.

HeatGenerationRate

Gets or sets the HeatGenerationRate.

JIntegral

Gets or sets the JIntegral.

MaterialForce

Gets or sets the MaterialForce.

CalculateReactions

Gets or sets the CalculateReactions.

SIFS

Gets or sets the SIFS.

Strain

Gets or sets the Strain.

Stress

Gets or sets the Stress.

CalculateThermalFlux

Gets or sets the CalculateThermalFlux.

TStress

Gets or sets the TStress.

CalculateVelocity

Gets or sets the CalculateVelocity.

CalculateVelocityAndAcceleration

Gets or sets the CalculateVelocityAndAcceleration.

CampbellDiagram

Gets or sets the CampbellDiagram.

CarryOverTimeStep

Gets or sets the CarryOverTimeStep.

DeleteUnneededFiles

Gets or sets the DeleteUnneededFiles.

CyclicModeSuperposition

Gets or sets the CyclicModeSuperposition.

Damped

Gets or sets the Damped.

EqvDampingRatioFromModal

Gets or sets the EqvDampingRatioFromModal.

ExcludeInsignificantModes

Gets or sets the ExcludeInsignificantModes.

ExportHighStrains

Gets or sets the ExportHighStrains.

ExportLayerEndTemperature

Gets or sets the ExportLayerEndTemperature.

ExportRecoaterInterference

Gets or sets the ExportRecoaterInterference.

FractureSolverControls

Gets or sets the FractureSolverControls.

GeneralMiscellaneous

Gets or sets the GeneralMiscellaneous.

ClusterResults

Gets or sets the ClusterResults.

UserDefinedFrequencies

Gets or sets the UserDefinedFrequencies.

Multistep

Gets or sets the Multistep.

IncludeResidualVector

Gets or sets the IncludeResidualVector.

InverseOption

Gets or sets the InverseOption.

KeepModalResults

Gets or sets the KeepModalResults.

KeepPreStressLoadPattern

Gets or sets the KeepPreStressLoadPattern.

NonLinearSolution

Gets the NonLinearSolution.

QuasiStaticSolution

Gets or sets the QuasiStaticSolution.

LimitSearchToRange

Gets or sets the LimitSearchToRange.

SaveMAPDLDB

Gets or sets the SaveMAPDLDB.

StoreComplexSolution

Gets or sets the StoreComplexSolution.

InertiaRelief

Gets or sets the InertiaRelief.

LargeDeflection

Gets or sets the LargeDeflection.

TimeIntegration

Gets or sets the TimeIntegration.

ElectricOnly

Gets or sets the ElectricOnly.

StructuralOnly

Gets or sets the StructuralOnly.

ThermalOnly

Gets or sets the ThermalOnly.

DataModelObjectCategory

Gets the current DataModelObject’s category.

Graph

Graph property.

ScratchSolverFilesDirectory

Gets the ScratchSolverFilesDirectory.

SolverFilesDirectory

Gets the SolverFilesDirectory.

Children

Gets the list of children.

Comments

Gets the list of associated comments.

Figures

Gets the list of associated figures.

Images

Gets the list of associated images.

InternalObject

Gets the internal object. For advanced usage only.

Properties

Gets the list of properties for this object.

VisibleProperties

Gets the list of properties that are visible for this object.

Property detail#

property ANSYSAnalysisSettings.StepName: System.String | None

Gets or sets the Step Name.

property ANSYSAnalysisSettings.AMStepType: Ansys.Mechanical.DataModel.Enums.AMProcessStepType | None

Gets or sets the AM Process Step Type.

property ANSYSAnalysisSettings.AMSubstepsToApplyHeats: System.Int32 | None

Gets or sets the AM Substeps to Apply Heat.

property ANSYSAnalysisSettings.AMSubstepsBetweenHeating: System.Int32 | None

Gets or sets the AM Substeps Between Heating.

property ANSYSAnalysisSettings.AMCooldownNumberOfSubsteps: System.Int32 | None

Gets or sets the AM Cooldown Number of Substeps.

property ANSYSAnalysisSettings.CooldownTimeType: Ansys.Mechanical.DataModel.Enums.AMCooldownTimeType | None

Gets or sets the AM Cooldown Time Type.

property ANSYSAnalysisSettings.CooldownTime: Ansys.Core.Units.Quantity | None

Gets or sets the AM Cooldown Time.

property ANSYSAnalysisSettings.LayersToBuild: System.Int32 | None

Gets or sets the AM Layers to Build.

property ANSYSAnalysisSettings.ReferenceTemperatureType: Ansys.Mechanical.DataModel.Enums.AMReferenceTemperatureType | None

Gets or sets the AM Reference Temperature Type.

property ANSYSAnalysisSettings.ReferenceTemperature: Ansys.Core.Units.Quantity | None

Gets or sets the AM Reference Temperature.

property ANSYSAnalysisSettings.RelaxationTemperatureType: Ansys.Mechanical.DataModel.Enums.AMRelaxationTemperatureType | None

Gets or sets the AM Relaxation Temperature Type.

property ANSYSAnalysisSettings.NumberOfRestartPoints: System.Int32 | None

Gets Number of Restart Points.

property ANSYSAnalysisSettings.CurrentRestartPoint: System.UInt32 | None

Gets or sets the Current Restart Point.

property ANSYSAnalysisSettings.AggressiveRemeshing: System.Boolean | None

Gets or sets the AggressiveRemeshing.

property ANSYSAnalysisSettings.SpinSoftening: Ansys.Mechanical.DataModel.Enums.SpinSofteningType | None

Gets or sets the SpinSoftening.

property ANSYSAnalysisSettings.UserDefinedFrequencySteps: System.Collections.Generic.IList[Ansys.Core.Units.Quantity] | None

Gets or sets the UserDefinedFrequencySteps.

property ANSYSAnalysisSettings.OutputSelection: Ansys.Mechanical.DataModel.Enums.OutputSelection | None

Gets or sets the Output Selection property in the Output Controls group of Analysis Settings.

property ANSYSAnalysisSettings.NamedSelection: System.Collections.Generic.IEnumerable[Ansys.ACT.Automation.Mechanical.NamedSelection] | None

Gets or sets the objects of type NamedSelection to – Named Selection property in the Output Controls group of Analysis Settings. If the OutputSelection != OutputSelection.NamedSelection, 1. NamedSelection cannot be set. An exception will be thrown saying “Cannot modify ANSYSAnalysisSettings.NamedSelection if ANSYSAnalysisSettings.OutputSelection is not set to “OutputSelection.NamedSelection”.” 2. Getting the NamedSelection value will return an empty list.

property ANSYSAnalysisSettings.InternalObject: Ansys.Common.Interop.DSObjectsAuto.IDSAnalysisSettings | None

Gets the internal object. For advanced usage only.

property ANSYSAnalysisSettings.MassCoefficient: System.Double | None

Gets or sets the MassCoefficient.

property ANSYSAnalysisSettings.StiffnessCoefficient: System.Double | None

Gets or sets the StiffnessCoefficient.

property ANSYSAnalysisSettings.DampingRatio: System.Double | None

Gets or sets the DampingRatio.

property ANSYSAnalysisSettings.ConstantDampingRatio: System.Double | None

Gets or sets the ConstantDampingRatio.

property ANSYSAnalysisSettings.StructuralDampingCoefficient: System.Double | None

Gets or sets the StructuralDampingCoefficient.

property ANSYSAnalysisSettings.ContactSplitMaxNum: System.UInt32 | None

Gets or sets the ContactSplitMaxNum.

property ANSYSAnalysisSettings.ChargeConvergenceTolerance: System.Double | None

Gets or sets the ChargeConvergenceTolerance.

property ANSYSAnalysisSettings.CurrentConvergenceTolerance: System.Double | None

Gets or sets the CurrentConvergenceTolerance.

property ANSYSAnalysisSettings.EmagAMPSConvergenceTolerance: System.Double | None

Gets or sets the EmagAMPSConvergenceTolerance.

property ANSYSAnalysisSettings.EmagCSGConvergenceTolerance: System.Double | None

Gets or sets the EmagCSGConvergenceTolerance.

property ANSYSAnalysisSettings.EnergyConvergenceTolerance: System.Double | None

Gets or sets the EnergyConvergenceTolerance.

property ANSYSAnalysisSettings.HeatConvergenceTolerance: System.Double | None

Gets or sets the HeatConvergenceTolerance.

property ANSYSAnalysisSettings.TemperatureConvergenceTolerance: System.Double | None

Gets or sets the TemperatureConvergenceTolerance.

property ANSYSAnalysisSettings.VoltageConvergenceTolerance: System.Double | None

Gets or sets the VoltageConvergenceTolerance.

property ANSYSAnalysisSettings.CreepLimitRatio: System.Double | None

Gets or sets the CreepLimitRatio.

property ANSYSAnalysisSettings.CurrentStepNumberHarmonic: System.UInt32 | None

Gets or sets the CurrentStepNumberHarmonic.

property ANSYSAnalysisSettings.CurrentStepNumber: System.UInt32 | None

Gets or sets the CurrentStepNumber.

property ANSYSAnalysisSettings.EngineOrderofExcitation: System.Int32 | None

Gets or sets the EngineOrderofExcitation.

property ANSYSAnalysisSettings.MaximumHarmonicIndex: System.Int32 | None

Gets or sets the MaximumHarmonicIndex.

property ANSYSAnalysisSettings.MinimumHarmonicIndex: System.Int32 | None

Gets or sets the MinimumHarmonicIndex.

property ANSYSAnalysisSettings.HarmonicIndexInterval: System.Int32 | None

Gets or sets the HarmonicIndexInterval.

property ANSYSAnalysisSettings.ClusterNumber: System.Int32 | None

Gets or sets the ClusterNumber.

property ANSYSAnalysisSettings.SolutionIntervals: System.Int32 | None

Gets or sets the SolutionIntervals.

property ANSYSAnalysisSettings.KrylovSubspaceDimension: System.Int32 | None

Gets or sets the KrylovSubspaceDimension.

property ANSYSAnalysisSettings.KrylovResidualTolerance: System.Double | None

Gets or sets the KrylovResidualTolerance.

property ANSYSAnalysisSettings.HarmonicOrders: System.String | None

Gets or sets the HarmonicOrders.

property ANSYSAnalysisSettings.InitialSubsteps: System.UInt32 | None

Gets or sets the InitialSubsteps.

property ANSYSAnalysisSettings.InverseOptionEndStep: System.UInt32 | None

Gets or sets the InverseOptionEndStep.

property ANSYSAnalysisSettings.MaximumSubsteps: System.UInt32 | None

Gets or sets the MaximumSubsteps.

property ANSYSAnalysisSettings.MeshLoadStepValue: System.UInt32 | None

Gets or sets the MeshLoadStepValue.

property ANSYSAnalysisSettings.MinimumSubsteps: System.UInt32 | None

Gets or sets the MinimumSubsteps.

property ANSYSAnalysisSettings.ModalNumberOfPoints: System.UInt32 | None

Gets or sets the ModalNumberOfPoints.

property ANSYSAnalysisSettings.ModeSignificanceLevel: System.Double | None

Gets or sets the ModeSignificanceLevel.

property ANSYSAnalysisSettings.GlobalSizeRatioQualityImprovement: System.Double | None

Gets or sets the GlobalSizeRatioQualityImprovement.

property ANSYSAnalysisSettings.GlobalSizeRatioQualityRefinement: System.Double | None

Gets or sets the GlobalSizeRatioQualityRefinement.

property ANSYSAnalysisSettings.NumberOfSculptedLayersQualityImprovement: System.UInt32 | None

Gets or sets the NumberOfSculptedLayersQualityImprovement.

property ANSYSAnalysisSettings.NumberOfSculptedLayersRefinement: System.UInt32 | None

Gets or sets the NumberOfSculptedLayersRefinement.

property ANSYSAnalysisSettings.RemeshingToleranceQualityImprovement: System.Double | None

Gets or sets the RemeshingToleranceQualityImprovement.

property ANSYSAnalysisSettings.RemeshingToleranceRefinement: System.Double | None

Gets or sets the RemeshingToleranceRefinement.

property ANSYSAnalysisSettings.StoreResulsAtValue: System.UInt32 | None

Gets or sets the StoreResulsAtValue.

property ANSYSAnalysisSettings.NumberOfModesToUse: System.Int32 | None

Gets or sets the NumberOfModesToUse.

property ANSYSAnalysisSettings.NumberOfRPMs: System.UInt32 | None

Gets or sets the NumberOfRPMs.

property ANSYSAnalysisSettings.NumberOfSteps: System.UInt32 | None

Gets or sets the NumberOfSteps.

property ANSYSAnalysisSettings.NumberOfSubSteps: System.UInt32 | None

Gets or sets the NumberOfSubSteps.

property ANSYSAnalysisSettings.NumericalDampingValue: System.Double | None

Gets or sets the NumericalDampingValue.

property ANSYSAnalysisSettings.NumLoadVectors: System.Int32 | None

Gets or sets the NumLoadVectors.

property ANSYSAnalysisSettings.MaximumModesToFind: System.Int32 | None

Gets or sets the MaximumModesToFind.

property ANSYSAnalysisSettings.NumberOfZones: System.Int32 | None

Gets or sets the NumberOfZones.

property ANSYSAnalysisSettings.AxisymmetryDivisions: System.Int32 | None

Gets or sets the AxisymmetryDivisions.

property ANSYSAnalysisSettings.HemicubeResolution: System.Int32 | None

Gets or sets the HemicubeResolution.

property ANSYSAnalysisSettings.FluxConvergence: System.Double | None

Gets or sets the FluxConvergence.

property ANSYSAnalysisSettings.MaximumIteration: System.Int32 | None

Gets or sets the MaximumIteration.

property ANSYSAnalysisSettings.OverRelaxation: System.Double | None

Gets or sets the OverRelaxation.

property ANSYSAnalysisSettings.ReformulationTolerance: System.Double | None

Gets or sets the ReformulationTolerance.

property ANSYSAnalysisSettings.RestartAtLoadStep: System.UInt32 | None

Gets the RestartAtLoadStep.

property ANSYSAnalysisSettings.RestartAtSubstep: System.UInt32 | None

Gets the RestartAtSubstep.

property ANSYSAnalysisSettings.RestartAtTime: System.Double | None

Gets the RestartAtTime.

property ANSYSAnalysisSettings.RpmClusterNumber: System.Int32 | None

Gets or sets the RpmClusterNumber.

property ANSYSAnalysisSettings.RpmSolutionIntervals: System.Int32 | None

Gets or sets the RpmSolutionIntervals.

property ANSYSAnalysisSettings.MaximumPointsToSavePerStep: System.UInt32 | None

Gets or sets the MaximumPointsToSavePerStep.

property ANSYSAnalysisSettings.SaveSpecifiedLoadStep: System.UInt32 | None

Gets or sets the SaveSpecifiedLoadStep.

property ANSYSAnalysisSettings.LoadStepValue: System.UInt32 | None

Gets or sets the LoadStepValue.

property ANSYSAnalysisSettings.SignificanceThreshold: System.Double | None

Gets or sets the SignificanceThreshold.

property ANSYSAnalysisSettings.StabilizationDampingFactor: System.Double | None

Gets or sets the StabilizationDampingFactor.

property ANSYSAnalysisSettings.StabilizationEnergyDissipationRatio: System.Double | None

Gets or sets the StabilizationEnergyDissipationRatio.

property ANSYSAnalysisSettings.StabilizationForceLimit: System.Double | None

Gets or sets the StabilizationForceLimit.

property ANSYSAnalysisSettings.TransientApplicationUserDefined: System.Double | None

Gets or sets the TransientApplicationUserDefined.

property ANSYSAnalysisSettings.SpringStiffnessFactor: System.Double | None

Gets or sets the SpringStiffnessFactor.

property ANSYSAnalysisSettings.RelaxationTemperature: Ansys.Core.Units.Quantity | None

Gets or sets the RelaxationTemperature.

property ANSYSAnalysisSettings.Frequency: Ansys.Core.Units.Quantity | None

Gets or sets the Frequency.

property ANSYSAnalysisSettings.CentralFrequency: Ansys.Core.Units.Quantity | None

Gets or sets the CentralFrequency.

property ANSYSAnalysisSettings.ChargeConvergenceMinimumReference: Ansys.Core.Units.Quantity | None

Gets or sets the ChargeConvergenceMinimumReference.

property ANSYSAnalysisSettings.ChargeConvergenceValue: Ansys.Core.Units.Quantity | None

Gets or sets the ChargeConvergenceValue.

property ANSYSAnalysisSettings.CurrentConvergenceMinimumReference: Ansys.Core.Units.Quantity | None

Gets or sets the CurrentConvergenceMinimumReference.

property ANSYSAnalysisSettings.CurrentConvergenceValue: Ansys.Core.Units.Quantity | None

Gets or sets the CurrentConvergenceValue.

property ANSYSAnalysisSettings.DisplacementConvergenceMinimumReference: Ansys.Core.Units.Quantity | None

Gets or sets the DisplacementConvergenceMinimumReference.

property ANSYSAnalysisSettings.DisplacementConvergenceTolerance: Ansys.Core.Units.Quantity | None

Gets or sets the DisplacementConvergenceTolerance.

property ANSYSAnalysisSettings.DisplacementConvergenceValue: Ansys.Core.Units.Quantity | None

Gets or sets the DisplacementConvergenceValue.

property ANSYSAnalysisSettings.EmagAMPSConvergenceMinimumReference: Ansys.Core.Units.Quantity | None

Gets or sets the EmagAMPSConvergenceMinimumReference.

property ANSYSAnalysisSettings.EmagAMPSConvergenceValue: Ansys.Core.Units.Quantity | None

Gets or sets the EmagAMPSConvergenceValue.

property ANSYSAnalysisSettings.EmagCSGConvergenceMinimumReference: Ansys.Core.Units.Quantity | None

Gets or sets the EmagCSGConvergenceMinimumReference.

property ANSYSAnalysisSettings.EmagCSGConvergenceValue: Ansys.Core.Units.Quantity | None

Gets or sets the EmagCSGConvergenceValue.

property ANSYSAnalysisSettings.EnergyConvergenceMinimumReference: Ansys.Core.Units.Quantity | None

Gets or sets the EnergyConvergenceMinimumReference.

property ANSYSAnalysisSettings.EnergyConvergenceValue: Ansys.Core.Units.Quantity | None

Gets or sets the EnergyConvergenceValue.

property ANSYSAnalysisSettings.ForceConvergenceMinimumReference: Ansys.Core.Units.Quantity | None

Gets or sets the ForceConvergenceMinimumReference.

property ANSYSAnalysisSettings.ForceConvergenceTolerance: Ansys.Core.Units.Quantity | None

Gets or sets the ForceConvergenceTolerance.

property ANSYSAnalysisSettings.ForceConvergenceValue: Ansys.Core.Units.Quantity | None

Gets or sets the ForceConvergenceValue.

property ANSYSAnalysisSettings.HeatConvergenceMinimumReference: Ansys.Core.Units.Quantity | None

Gets or sets the HeatConvergenceMinimumReference.

property ANSYSAnalysisSettings.HeatConvergenceValue: Ansys.Core.Units.Quantity | None

Gets or sets the HeatConvergenceValue.

property ANSYSAnalysisSettings.MomentConvergenceMinimumReference: Ansys.Core.Units.Quantity | None

Gets or sets the MomentConvergenceMinimumReference.

property ANSYSAnalysisSettings.MomentConvergenceTolerance: Ansys.Core.Units.Quantity | None

Gets or sets the MomentConvergenceTolerance.

property ANSYSAnalysisSettings.MomentConvergenceValue: Ansys.Core.Units.Quantity | None

Gets or sets the MomentConvergenceValue.

property ANSYSAnalysisSettings.RotationConvergenceMinimumReference: Ansys.Core.Units.Quantity | None

Gets or sets the RotationConvergenceMinimumReference.

property ANSYSAnalysisSettings.RotationConvergenceTolerance: Ansys.Core.Units.Quantity | None

Gets or sets the RotationConvergenceTolerance.

property ANSYSAnalysisSettings.TemperatureConvergenceMinimumReference: Ansys.Core.Units.Quantity | None

Gets or sets the TemperatureConvergenceMinimumReference.

property ANSYSAnalysisSettings.TemperatureConvergenceInputValue: Ansys.Core.Units.Quantity | None

Gets or sets the TemperatureConvergenceInputValue.

property ANSYSAnalysisSettings.VoltageConvergenceMinimumReference: Ansys.Core.Units.Quantity | None

Gets or sets the VoltageConvergenceMinimumReference.

property ANSYSAnalysisSettings.VoltageConvergenceValue: Ansys.Core.Units.Quantity | None

Gets or sets the VoltageConvergenceValue.

property ANSYSAnalysisSettings.RemovalDirection: Ansys.Core.Units.Quantity | None

Gets or sets the RemovalDirection.

property ANSYSAnalysisSettings.RemovalStepSize: Ansys.Core.Units.Quantity | None

Gets or sets the RemovalStepSize.

property ANSYSAnalysisSettings.StepEndTime: Ansys.Core.Units.Quantity | None

Gets or sets the StepEndTime.

property ANSYSAnalysisSettings.MinimumElementSize: Ansys.Core.Units.Quantity | None

Gets or sets the Minimum Element Size property for Geometry Based Adaptivity.

property ANSYSAnalysisSettings.RangeMaximum: Ansys.Core.Units.Quantity | None

Gets or sets the Range Maximum property in Options group of Analysis Settings in Harmonic Analysis.

property ANSYSAnalysisSettings.RangeMinimum: Ansys.Core.Units.Quantity | None

Gets or sets the Range Minimum property in Options group of Analysis Settings in Harmonic Analysis.

property ANSYSAnalysisSettings.KrylovSubspaceFrequency: Ansys.Core.Units.Quantity | None

Gets or sets the KrylovSubspaceFrequency.

property ANSYSAnalysisSettings.ModalRangeMaximum: Ansys.Core.Units.Quantity | None

Gets or sets the ModalRangeMaximum.

property ANSYSAnalysisSettings.ModalRangeMinimum: Ansys.Core.Units.Quantity | None

Gets or sets the ModalRangeMinimum.

property ANSYSAnalysisSettings.InitialTimeStep: Ansys.Core.Units.Quantity | None

Gets or sets the InitialTimeStep.

property ANSYSAnalysisSettings.SearchRangeMaximum: Ansys.Core.Units.Quantity | None

Gets or sets the Range Maximum property in Options group of Analysis Settings in Modal Analysis.

property ANSYSAnalysisSettings.MaximumTimeStep: Ansys.Core.Units.Quantity | None

Gets or sets the MaximumTimeStep.

property ANSYSAnalysisSettings.SearchRangeMinimum: Ansys.Core.Units.Quantity | None

Gets or sets the Range Minimum property in Options group of Analysis Settings in Modal Analysis.

property ANSYSAnalysisSettings.MinimumTimeStep: Ansys.Core.Units.Quantity | None

Gets or sets the MinimumTimeStep.

property ANSYSAnalysisSettings.BoundaryAngle: Ansys.Core.Units.Quantity | None

Gets or sets the BoundaryAngle.

property ANSYSAnalysisSettings.EdgeSplittingAngle: Ansys.Core.Units.Quantity | None

Gets or sets the EdgeSplittingAngle.

property ANSYSAnalysisSettings.SolverTolerance: Ansys.Core.Units.Quantity | None

Gets or sets the SolverTolerance.

property ANSYSAnalysisSettings.RpmValue: Ansys.Core.Units.Quantity | None

Gets or sets the RpmValue.

property ANSYSAnalysisSettings.RpmCentralFrequency: Ansys.Core.Units.Quantity | None

Gets or sets the RpmCentralFrequency.

property ANSYSAnalysisSettings.RpmRangeMaximum: Ansys.Core.Units.Quantity | None

Gets or sets the RpmRangeMaximum.

property ANSYSAnalysisSettings.RpmRangeMinimum: Ansys.Core.Units.Quantity | None

Gets or sets the RpmRangeMinimum.

property ANSYSAnalysisSettings.TimeStep: Ansys.Core.Units.Quantity | None

Gets or sets the TimeStep.

property ANSYSAnalysisSettings.SpringStiffnessValue: Ansys.Core.Units.Quantity | None

Gets or sets the SpringStiffnessValue.

property ANSYSAnalysisSettings.BaseRemovalType: Ansys.Mechanical.DataModel.Enums.AMBaseRemovalType | None

Gets or sets the BaseRemovalType.

property ANSYSAnalysisSettings.StiffnessCoefficientDefineBy: Ansys.Mechanical.DataModel.Enums.DampingType | None

Gets or sets the StiffnessCoefficientDefineBy.

property ANSYSAnalysisSettings.CacheResultsInMemory: Ansys.Mechanical.DataModel.Enums.CacheResultsInMemory | None

Gets or sets the CacheResultsInMemory.

property ANSYSAnalysisSettings.ParticipationFactor: Ansys.Mechanical.DataModel.Enums.CalculateParticipationFactorResult | None

Gets or sets the ParticipationFactor.

property ANSYSAnalysisSettings.StoreResultsAt: Ansys.Mechanical.DataModel.Enums.TimePointsOptions | None

Gets or sets the StoreResultsAt.

property ANSYSAnalysisSettings.ConstantDamping: Ansys.Mechanical.DataModel.Enums.ConstantDampingType | None

Gets or sets the ConstantDamping.

property ANSYSAnalysisSettings.ContactSplit: Ansys.Mechanical.DataModel.Enums.ContactSplitType | None

Gets or sets the ContactSplit.

property ANSYSAnalysisSettings.ContactSummary: Ansys.Mechanical.DataModel.Enums.ContactSummaryType | None

Gets or sets the ContactSummary.

property ANSYSAnalysisSettings.ChargeConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None

Gets or sets the ChargeConvergence.

property ANSYSAnalysisSettings.CurrentConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None

Gets or sets the CurrentConvergence.

property ANSYSAnalysisSettings.DisplacementConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None

Gets or sets the DisplacementConvergence.

property ANSYSAnalysisSettings.AMPSConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None

Gets or sets the AMPSConvergence.

property ANSYSAnalysisSettings.CSGConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None

Gets or sets the CSGConvergence.

property ANSYSAnalysisSettings.EnergyConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None

Gets or sets the EnergyConvergence.

property ANSYSAnalysisSettings.ForceConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None

Gets or sets the ForceConvergence.

property ANSYSAnalysisSettings.HeatConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None

Gets or sets the HeatConvergence.

property ANSYSAnalysisSettings.MomentConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None

Gets or sets the MomentConvergence.

property ANSYSAnalysisSettings.RotationConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None

Gets or sets the RotationConvergence.

property ANSYSAnalysisSettings.TemperatureConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None

Gets or sets the TemperatureConvergence.

property ANSYSAnalysisSettings.TemperatureConvergenceValue: Ansys.Mechanical.DataModel.Enums.NonLinearValueType | None

Gets or sets the TemperatureConvergenceValue.

property ANSYSAnalysisSettings.VoltageConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None

Gets or sets the VoltageConvergence.

property ANSYSAnalysisSettings.CoriolisEffectApplied: Ansys.Mechanical.DataModel.Enums.CoriolisEffectType | None

Gets or sets the CoriolisEffectApplied.

property ANSYSAnalysisSettings.CreepEffects: Ansys.Mechanical.DataModel.Enums.Creep | None

Gets or sets the CreepEffects.

property ANSYSAnalysisSettings.HarmonicIndexRange: Ansys.Mechanical.DataModel.Enums.CyclicHarmonicIndex | None

Gets or sets the HarmonicIndexRange.

property ANSYSAnalysisSettings.DampingDefineBy: Ansys.Mechanical.DataModel.Enums.DampingDefineBy | None

Gets or sets the DampingDefineBy.

property ANSYSAnalysisSettings.FarFieldRadiationSurface: Ansys.Mechanical.DataModel.Enums.FarFieldRadiationSurfaceType | None

Gets or sets the FarFieldRadiationSurface.

property ANSYSAnalysisSettings.ExpandResultsFrom: Ansys.Mechanical.DataModel.Enums.ExpandResultFrom | None

Gets or sets the ExpandResultsFrom.

property ANSYSAnalysisSettings.FrequencySpacing: Ansys.Mechanical.DataModel.Enums.FrequencySpacingType | None

Gets or sets the FrequencySpacing.

property ANSYSAnalysisSettings.FutureAnalysis: Ansys.Mechanical.DataModel.Enums.FutureIntentType | None

Gets or sets the FutureAnalysis.

property ANSYSAnalysisSettings.GeneralMiscellaneousOption: Ansys.Mechanical.DataModel.Enums.GeneralMiscellaneousOptionType | None

Gets or sets the GeneralMiscellaneousOption.

property ANSYSAnalysisSettings.MultistepType: Ansys.Mechanical.DataModel.Enums.HarmonicMultiStepType | None

Gets or sets the MultistepType.

property ANSYSAnalysisSettings.ModalFrequencyRange: Ansys.Mechanical.DataModel.Enums.ModalFrequencyRangeType | None

Gets or sets the ModalFrequencyRange.

property ANSYSAnalysisSettings.StoreResultsAtAllFrequencies: Ansys.Mechanical.DataModel.Enums.HarmonicMSUPStorage | None

Gets or sets the StoreResultsAtAllFrequencies.

property ANSYSAnalysisSettings.SolutionMethod: Ansys.Mechanical.DataModel.Enums.HarmonicMethod | None

Gets or sets the SolutionMethod.

property ANSYSAnalysisSettings.IncludeNegativeLoadMultiplier: Ansys.Mechanical.DataModel.Enums.SolverControlsIncludeNegativeLoadMultiplier | None

Gets or sets the IncludeNegativeLoadMultiplier.

property ANSYSAnalysisSettings.LineSearch: Ansys.Mechanical.DataModel.Enums.LineSearchType | None

Gets or sets the LineSearch.

property ANSYSAnalysisSettings.GenerateMeshRestartPoints: Ansys.Mechanical.DataModel.Enums.MeshRestartControlsType | None

Gets or sets the GenerateMeshRestartPoints.

property ANSYSAnalysisSettings.MeshRetainFilesAfterFullSolve: Ansys.Mechanical.DataModel.Enums.MeshRestartRetainFilesType | None

Gets or sets the MeshRetainFilesAfterFullSolve.

property ANSYSAnalysisSettings.MeshSaveAtLoadStep: Ansys.Mechanical.DataModel.Enums.MeshRestartSaveAtLoadStep | None

Gets or sets the MeshSaveAtLoadStep.

property ANSYSAnalysisSettings.MeshSaveAtSubstep: Ansys.Mechanical.DataModel.Enums.MeshRestartSaveAtSubstep | None

Gets or sets the MeshSaveAtSubstep.

property ANSYSAnalysisSettings.ModeReuse: Ansys.Mechanical.DataModel.Enums.SolverControlsModeReuse | None

Gets or sets the ModeReuse.

property ANSYSAnalysisSettings.ModesCombinationType: Ansys.Mechanical.DataModel.Enums.ModesCombinationType | None

Gets or sets the ModesCombinationType.

property ANSYSAnalysisSettings.ModeSelectionMethod: Ansys.Mechanical.DataModel.Enums.ModeSelectionMethod | None

Gets or sets the ModeSelectionMethod.

property ANSYSAnalysisSettings.OnDemandExpansionOption: Ansys.Mechanical.DataModel.Enums.OnDemandExpansionType | None

Gets or sets the OnDemandExpansionOption.

property ANSYSAnalysisSettings.NewtonRaphsonOption: Ansys.Mechanical.DataModel.Enums.NewtonRaphsonType | None

Gets or sets the NewtonRaphsonOption.

property ANSYSAnalysisSettings.NodalForces: Ansys.Mechanical.DataModel.Enums.OutputControlsNodalForcesType | None

Gets or sets the NodalForces.

property ANSYSAnalysisSettings.ProjectToGeometry: Ansys.Mechanical.DataModel.Enums.NLADControlProjectToGeometry | None

Gets or sets the ProjectToGeometry.

property ANSYSAnalysisSettings.RefinementAlgorithm: Ansys.Mechanical.DataModel.Enums.NonlinearAdaptivityControlsRefinementAlgorithmType | None

Gets or sets the RefinementAlgorithm.

property ANSYSAnalysisSettings.RemeshingGradient: Ansys.Mechanical.DataModel.Enums.NonlinearAdaptivityControlsRemeshingGradientType | None

Gets or sets the RemeshingGradient.

property ANSYSAnalysisSettings.NonLinearFormulation: Ansys.Mechanical.DataModel.Enums.NonLinearFormulationType | None

Gets or sets the NonLinearFormulation.

property ANSYSAnalysisSettings.NumericalDamping: Ansys.Mechanical.DataModel.Enums.TransientDampingType | None

Gets or sets the NumericalDamping.

property ANSYSAnalysisSettings.Expansion: Ansys.Mechanical.DataModel.Enums.ExpandResultsSubType | None

Gets the Expansion.

property ANSYSAnalysisSettings.ViewFactorMethod: Ansys.Mechanical.DataModel.Enums.RadiosityViewFactorType | None

Gets or sets the ViewFactorMethod.

property ANSYSAnalysisSettings.RadiositySolver: Ansys.Mechanical.DataModel.Enums.RadiositySolverType | None

Gets or sets the RadiositySolver.

property ANSYSAnalysisSettings.CombineRestartFiles: Ansys.Mechanical.DataModel.Enums.CombineRestartFilesType | None

Gets or sets the CombineRestartFiles.

property ANSYSAnalysisSettings.GenerateRestartPoints: Ansys.Mechanical.DataModel.Enums.RestartControlsType | None

Gets or sets the GenerateRestartPoints.

property ANSYSAnalysisSettings.RetainFilesAfterFullSolve: Ansys.Mechanical.DataModel.Enums.RestartRetainFilesType | None

Gets or sets the RetainFilesAfterFullSolve.

property ANSYSAnalysisSettings.RestartType: Ansys.Mechanical.DataModel.Enums.RestartType | None

Gets or sets the RestartType.

property ANSYSAnalysisSettings.ResultFileCompression: Ansys.Mechanical.DataModel.Enums.ResultFileCompressionType | None

Gets or sets the ResultFileCompression.

property ANSYSAnalysisSettings.RpmFrequencySpacing: Ansys.Mechanical.DataModel.Enums.FrequencySpacingType | None

Gets or sets the RpmFrequencySpacing.

property ANSYSAnalysisSettings.SaveAtLoadStep: Ansys.Mechanical.DataModel.Enums.RestartSaveAtLoadStep | None

Gets or sets the SaveAtLoadStep.

property ANSYSAnalysisSettings.SaveAtSubstep: Ansys.Mechanical.DataModel.Enums.RestartSaveAtSubstep | None

Gets or sets the SaveAtSubstep.

property ANSYSAnalysisSettings.ScatteredFieldFormulation: Ansys.Mechanical.DataModel.Enums.ScatteredFieldFormulation | None

Gets or sets the ScatteredFieldFormulation.

property ANSYSAnalysisSettings.ScatteringOutputType: Ansys.Mechanical.DataModel.Enums.ScatteringOutputType | None

Gets or sets the ScatteringOutputType.

property ANSYSAnalysisSettings.SolverUnitSystem: Ansys.Mechanical.DataModel.Enums.WBUnitSystemType | None

Gets or sets the SolverUnitSystem.

property ANSYSAnalysisSettings.SolverPivotChecking: Ansys.Mechanical.DataModel.Enums.SolverPivotChecking | None

Gets or sets the SolverPivotChecking.

property ANSYSAnalysisSettings.SolverType: Ansys.Mechanical.DataModel.Enums.SolverType | None

Gets or sets the SolverType.

property ANSYSAnalysisSettings.SolverUnits: Ansys.Mechanical.DataModel.Enums.SolverUnitsControlType | None

Gets or sets the SolverUnits.

property ANSYSAnalysisSettings.SpectrumType: Ansys.Mechanical.DataModel.Enums.SpectrumType | None

Gets or sets the SpectrumType.

property ANSYSAnalysisSettings.Stabilization: Ansys.Mechanical.DataModel.Enums.StabilizationType | None

Gets or sets the Stabilization.

property ANSYSAnalysisSettings.StabilizationActivationForFirstSubstep: Ansys.Mechanical.DataModel.Enums.StabilizationFirstSubstepOption | None

Gets or sets the StabilizationActivationForFirstSubstep.

property ANSYSAnalysisSettings.StabilizationMethod: Ansys.Mechanical.DataModel.Enums.StabilizationMethod | None

Gets or sets the StabilizationMethod.

property ANSYSAnalysisSettings.StoreModalResults: Ansys.Mechanical.DataModel.Enums.StoreModalResult | None

Gets or sets the StoreModalResults.

property ANSYSAnalysisSettings.DefineBy: Ansys.Mechanical.DataModel.Enums.TimeStepDefineByType | None

Gets or sets the DefineBy.

property ANSYSAnalysisSettings.TransientApplication: Ansys.Mechanical.DataModel.Enums.TransientApplicationType | None

Gets or sets the TransientApplication.

property ANSYSAnalysisSettings.UpdateViewFactor: Ansys.Mechanical.DataModel.Enums.UpdateViewFactor | None

Gets or sets the specification for updating the view factor.

property ANSYSAnalysisSettings.AutomaticTimeStepping: Ansys.Mechanical.DataModel.Enums.AutomaticTimeStepping | None

Gets or sets the AutomaticTimeStepping.

property ANSYSAnalysisSettings.RetainModesymFileAfterSolve: Ansys.Mechanical.DataModel.Enums.UseExistingModesymFile | None

Gets or sets the RetainModesymFileAfterSolve.

property ANSYSAnalysisSettings.WeakSprings: Ansys.Mechanical.DataModel.Enums.WeakSpringsType | None

Gets or sets the WeakSprings.

property ANSYSAnalysisSettings.SpringStiffness: Ansys.Mechanical.DataModel.Enums.SpringsStiffnessType | None

Gets or sets the SpringStiffness.

property ANSYSAnalysisSettings.IgnoreAcousticDamping: System.Boolean | None

Gets or sets the IgnoreAcousticDamping.

property ANSYSAnalysisSettings.CalculateAcceleration: System.Boolean | None

Gets or sets the CalculateAcceleration.

property ANSYSAnalysisSettings.BackStress: System.Boolean | None

Gets or sets the BackStress.

property ANSYSAnalysisSettings.ContactMiscellaneous: System.Boolean | None

Gets or sets the ContactMiscellaneous.

property ANSYSAnalysisSettings.CStarIntegral: System.Boolean | None

Gets or sets the CStarIntegral.

property ANSYSAnalysisSettings.ElementCurrentDensity: System.Boolean | None

Gets or sets the ElementCurrentDensity.

property ANSYSAnalysisSettings.FieldIntensityandFluxDensity: System.Boolean | None

Gets or sets the FieldIntensityandFluxDensity.

property ANSYSAnalysisSettings.ElectromagneticNodalForces: System.Boolean | None

Gets or sets the ElectromagneticNodalForces.

property ANSYSAnalysisSettings.ContactData: System.Boolean | None

Gets or sets the ContactData.

property ANSYSAnalysisSettings.CalculateVolumeEnergy: System.Boolean | None

Gets or sets the CalculateVolumeEnergy.

property ANSYSAnalysisSettings.NonlinearData: System.Boolean | None

Gets or sets the NonlinearData.

property ANSYSAnalysisSettings.CalculateEnergy: System.Boolean | None

Gets or sets the CalculateEnergy.

property ANSYSAnalysisSettings.CalculateEulerAngles: System.Boolean | None

Gets or sets the CalculateEulerAngles.

property ANSYSAnalysisSettings.HeatGenerationRate: System.Boolean | None

Gets or sets the HeatGenerationRate.

property ANSYSAnalysisSettings.JIntegral: System.Boolean | None

Gets or sets the JIntegral.

property ANSYSAnalysisSettings.MaterialForce: System.Boolean | None

Gets or sets the MaterialForce.

property ANSYSAnalysisSettings.CalculateReactions: System.Boolean | None

Gets or sets the CalculateReactions.

property ANSYSAnalysisSettings.SIFS: System.Boolean | None

Gets or sets the SIFS.

property ANSYSAnalysisSettings.Strain: System.Boolean | None

Gets or sets the Strain.

property ANSYSAnalysisSettings.Stress: System.Boolean | None

Gets or sets the Stress.

property ANSYSAnalysisSettings.CalculateThermalFlux: System.Boolean | None

Gets or sets the CalculateThermalFlux.

property ANSYSAnalysisSettings.TStress: System.Boolean | None

Gets or sets the TStress.

property ANSYSAnalysisSettings.CalculateVelocity: System.Boolean | None

Gets or sets the CalculateVelocity.

property ANSYSAnalysisSettings.CalculateVelocityAndAcceleration: System.Boolean | None

Gets or sets the CalculateVelocityAndAcceleration.

property ANSYSAnalysisSettings.CampbellDiagram: System.Boolean | None

Gets or sets the CampbellDiagram.

property ANSYSAnalysisSettings.CarryOverTimeStep: System.Boolean | None

Gets or sets the CarryOverTimeStep.

property ANSYSAnalysisSettings.DeleteUnneededFiles: System.Boolean | None

Gets or sets the DeleteUnneededFiles.

property ANSYSAnalysisSettings.CyclicModeSuperposition: System.Boolean | None

Gets or sets the CyclicModeSuperposition.

property ANSYSAnalysisSettings.Damped: System.Boolean | None

Gets or sets the Damped.

property ANSYSAnalysisSettings.EqvDampingRatioFromModal: System.Boolean | None

Gets or sets the EqvDampingRatioFromModal.

property ANSYSAnalysisSettings.ExcludeInsignificantModes: System.Boolean | None

Gets or sets the ExcludeInsignificantModes.

property ANSYSAnalysisSettings.ExportHighStrains: System.Boolean | None

Gets or sets the ExportHighStrains.

property ANSYSAnalysisSettings.ExportLayerEndTemperature: System.Boolean | None

Gets or sets the ExportLayerEndTemperature.

property ANSYSAnalysisSettings.ExportRecoaterInterference: System.Boolean | None

Gets or sets the ExportRecoaterInterference.

property ANSYSAnalysisSettings.FractureSolverControls: System.Boolean | None

Gets or sets the FractureSolverControls.

property ANSYSAnalysisSettings.GeneralMiscellaneous: System.Boolean | None

Gets or sets the GeneralMiscellaneous.

property ANSYSAnalysisSettings.ClusterResults: System.Boolean | None

Gets or sets the ClusterResults.

property ANSYSAnalysisSettings.UserDefinedFrequencies: System.Boolean | None

Gets or sets the UserDefinedFrequencies.

property ANSYSAnalysisSettings.Multistep: System.Boolean | None

Gets or sets the Multistep.

property ANSYSAnalysisSettings.IncludeResidualVector: System.Boolean | None

Gets or sets the IncludeResidualVector.

property ANSYSAnalysisSettings.InverseOption: System.Boolean | None

Gets or sets the InverseOption.

property ANSYSAnalysisSettings.KeepModalResults: System.Boolean | None

Gets or sets the KeepModalResults.

property ANSYSAnalysisSettings.KeepPreStressLoadPattern: System.Boolean | None

Gets or sets the KeepPreStressLoadPattern.

property ANSYSAnalysisSettings.NonLinearSolution: System.Boolean | None

Gets the NonLinearSolution.

property ANSYSAnalysisSettings.QuasiStaticSolution: System.Boolean | None

Gets or sets the QuasiStaticSolution.

property ANSYSAnalysisSettings.LimitSearchToRange: System.Boolean | None

Gets or sets the LimitSearchToRange.

property ANSYSAnalysisSettings.SaveMAPDLDB: System.Boolean | None

Gets or sets the SaveMAPDLDB.

property ANSYSAnalysisSettings.StoreComplexSolution: System.Boolean | None

Gets or sets the StoreComplexSolution.

property ANSYSAnalysisSettings.InertiaRelief: System.Boolean | None

Gets or sets the InertiaRelief.

property ANSYSAnalysisSettings.LargeDeflection: System.Boolean | None

Gets or sets the LargeDeflection.

property ANSYSAnalysisSettings.TimeIntegration: System.Boolean | None

Gets or sets the TimeIntegration.

property ANSYSAnalysisSettings.ElectricOnly: System.Boolean | None

Gets or sets the ElectricOnly.

property ANSYSAnalysisSettings.StructuralOnly: System.Boolean | None

Gets or sets the StructuralOnly.

property ANSYSAnalysisSettings.ThermalOnly: System.Boolean | None

Gets or sets the ThermalOnly.

property ANSYSAnalysisSettings.DataModelObjectCategory: Ansys.Mechanical.DataModel.Enums.DataModelObjectCategory | None

Gets the current DataModelObject’s category.

property ANSYSAnalysisSettings.Graph: Ansys.Mechanical.Graphics.AnalysisSettingsGraph | None

Graph property.

property ANSYSAnalysisSettings.ScratchSolverFilesDirectory: System.String | None

Gets the ScratchSolverFilesDirectory.

property ANSYSAnalysisSettings.SolverFilesDirectory: System.String | None

Gets the SolverFilesDirectory.

property ANSYSAnalysisSettings.Children: System.Collections.Generic.IList[Ansys.Mechanical.DataModel.Interfaces.IDataModelObject] | None

Gets the list of children.

property ANSYSAnalysisSettings.Comments: System.Collections.Generic.IEnumerable[Ansys.ACT.Automation.Mechanical.Comment] | None

Gets the list of associated comments.

property ANSYSAnalysisSettings.Figures: System.Collections.Generic.IEnumerable[Ansys.ACT.Automation.Mechanical.Figure] | None

Gets the list of associated figures.

property ANSYSAnalysisSettings.Images: System.Collections.Generic.IEnumerable[Ansys.ACT.Automation.Mechanical.Image] | None

Gets the list of associated images.

property ANSYSAnalysisSettings.InternalObject: System.Object | None

Gets the internal object. For advanced usage only.

property ANSYSAnalysisSettings.Properties: System.Collections.Generic.IReadOnlyList[Ansys.ACT.Automation.Mechanical.Property] | None

Gets the list of properties for this object.

property ANSYSAnalysisSettings.VisibleProperties: System.Collections.Generic.IReadOnlyList[Ansys.ACT.Automation.Mechanical.Property] | None

Gets the list of properties that are visible for this object.

Method detail#

ANSYSAnalysisSettings.GetStepEndTime(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the Step End Time at a given solution step.

ANSYSAnalysisSettings.SetStepEndTime(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Step End Time for a given solution step.

ANSYSAnalysisSettings.GetAutomaticTimeStepping(stepNumber: System.UInt32) Ansys.Mechanical.DataModel.Enums.AutomaticTimeStepping

Gets the Automatic Time Stepping at a given solution step.

ANSYSAnalysisSettings.SetAutomaticTimeStepping(stepNumber: System.UInt32, value: Ansys.Mechanical.DataModel.Enums.AutomaticTimeStepping) System.Void

Sets the Automatic Time Stepping for a given solution step.

ANSYSAnalysisSettings.GetForceConvergenceType(stepNumber: System.UInt32) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType

Gets the Force Convergence Tolerance Type at a given solution step.

ANSYSAnalysisSettings.SetForceConvergenceType(stepNumber: System.UInt32, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) System.Void

Sets the Force Convergence Tolerance Type for a given solution step.

ANSYSAnalysisSettings.GetForceConvergenceTolerance(stepNumber: System.UInt32) System.Double

Gets the Force Convergence Tolerance as a percentage at a given solution step.

ANSYSAnalysisSettings.SetForceConvergenceTolerance(stepNumber: System.UInt32, value: System.Double) System.Void
Sets the Force Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
ANSYSAnalysisSettings.GetForceConvergenceValue(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the Force Convergence Value at a given solution step.

ANSYSAnalysisSettings.SetForceConvergenceValue(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Force Convergence Value for a given solution step.

ANSYSAnalysisSettings.GetForceConvergenceMinimumReference(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the Force Convergence Minimum Reference at a given solution step.

ANSYSAnalysisSettings.SetForceConvergenceMinimumReference(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Force Convergence Minimum Reference for a given solution step.

ANSYSAnalysisSettings.GetMomentConvergenceType(stepNumber: System.UInt32) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType

Gets the Moment Convergence Tolerance type at a given solution step.

ANSYSAnalysisSettings.SetMomentConvergenceType(stepNumber: System.UInt32, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) System.Void

Sets the Moment Convergence Tolerance type for a given solution step.

ANSYSAnalysisSettings.GetMomentConvergenceTolerance(stepNumber: System.UInt32) System.Double

Gets the Moment Convergence Tolerance as a percentage at a given solution step.

ANSYSAnalysisSettings.SetMomentConvergenceTolerance(stepNumber: System.UInt32, value: System.Double) System.Void
Sets the Moment Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
ANSYSAnalysisSettings.GetMomentConvergenceValue(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the Moment Convergence Value at a given solution step.

ANSYSAnalysisSettings.SetMomentConvergenceValue(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Moment Convergence Value for a given solution step.

ANSYSAnalysisSettings.GetMomentConvergenceMinimumReference(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the Moment Convergence Minimum Reference at a given solution step.

ANSYSAnalysisSettings.SetMomentConvergenceMinimumReference(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Moment Convergence Minimum Reference for a given solution step.

ANSYSAnalysisSettings.GetDisplacementConvergenceType(stepNumber: System.UInt32) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType

Gets the Displacement Convergence Tolerance type at a given solution step.

ANSYSAnalysisSettings.SetDisplacementConvergenceType(stepNumber: System.UInt32, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) System.Void

Sets the Displacement Convergence Tolerance type for a given solution step.

ANSYSAnalysisSettings.GetDisplacementConvergenceTolerance(stepNumber: System.UInt32) System.Double

Gets the Displacement Convergence Tolerance as a percentage at a given solution step.

ANSYSAnalysisSettings.SetDisplacementConvergenceTolerance(stepNumber: System.UInt32, value: System.Double) System.Void
Sets the Displacement Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
ANSYSAnalysisSettings.GetDisplacementConvergenceValue(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the Displacement Convergence Value at a given solution step.

ANSYSAnalysisSettings.SetDisplacementConvergenceValue(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Displacement Convergence Value for a given solution step.

ANSYSAnalysisSettings.GetDisplacementConvergenceMinimumReference(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the Displacement Convergence Minimum Reference at a given solution step.

ANSYSAnalysisSettings.SetDisplacementConvergenceMinimumReference(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Displacement Convergence Minimum Reference for a given solution step.

ANSYSAnalysisSettings.GetRotationConvergenceType(stepNumber: System.UInt32) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType

Gets the Rotation Convergence Tolerance type at a given solution step.

ANSYSAnalysisSettings.SetRotationConvergenceType(stepNumber: System.UInt32, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) System.Void

Sets the Rotation Convergence Tolerance type for a given solution step.

ANSYSAnalysisSettings.GetRotationConvergenceTolerance(stepNumber: System.UInt32) System.Double

Gets the Rotation Convergence Tolerance as a percentage at a given solution step.

ANSYSAnalysisSettings.SetRotationConvergenceTolerance(stepNumber: System.UInt32, value: System.Double) System.Void
Sets the Rotation Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
ANSYSAnalysisSettings.GetRotationConvergenceValue(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the Rotation Convergence Value at a given solution step.

ANSYSAnalysisSettings.SetRotationConvergenceValue(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Rotation Convergence Value for a given solution step.

ANSYSAnalysisSettings.GetRotationConvergenceMinimumReference(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the Rotation Convergence Minimum Reference at a given solution step.

ANSYSAnalysisSettings.SetRotationConvergenceMinimumReference(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Rotation Convergence Minimum Reference for a given solution step.

ANSYSAnalysisSettings.SetTemperatureConvergenceType(stepNumber: System.UInt32, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) System.Void

Sets the Temperature Convergence Tolerance type for a given solution step.

ANSYSAnalysisSettings.SetTemperatureConvergenceTolerance(stepNumber: System.UInt32, value: System.Double) System.Void
Sets the Temperature Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
ANSYSAnalysisSettings.SetTemperatureConvergenceValue(stepNumber: System.UInt32, value: Ansys.Mechanical.DataModel.Enums.NonLinearValueType) System.Void

Sets the Temperature Convergence Value for a given solution step.

ANSYSAnalysisSettings.SetTemperatureConvergenceInputValue(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Temperature Convergence Input Value for a given solution step.

ANSYSAnalysisSettings.SetTemperatureConvergenceMinimumReference(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Temperature Convergence Minimum Reference for a given solution step.

ANSYSAnalysisSettings.SetHeatConvergenceType(stepNumber: System.UInt32, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) System.Void

Sets the Heat Convergence Tolerance type for a given solution step.

ANSYSAnalysisSettings.SetHeatConvergenceTolerance(stepNumber: System.UInt32, value: System.Double) System.Void
Sets the Heat Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
ANSYSAnalysisSettings.SetHeatConvergenceValue(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Heat Convergence Value for a given solution step.

ANSYSAnalysisSettings.SetHeatConvergenceMinimumReference(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Heat Convergence Minimum Reference for a given solution step.

ANSYSAnalysisSettings.SetVoltageConvergenceType(stepNumber: System.UInt32, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) System.Void

Sets the Voltage Convergence Tolerance type for a given solution step.

ANSYSAnalysisSettings.SetVoltageConvergenceTolerance(stepNumber: System.UInt32, value: System.Double) System.Void
Sets the Voltage Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
ANSYSAnalysisSettings.SetVoltageConvergenceValue(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Voltage Convergence Value for a given solution step.

ANSYSAnalysisSettings.SetVoltageConvergenceMinimumReference(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Voltage Convergence Minimum Reference for a given solution step.

ANSYSAnalysisSettings.SetChargeConvergenceType(stepNumber: System.UInt32, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) System.Void

Sets the Charge Convergence Tolerance type for a given solution step.

ANSYSAnalysisSettings.SetChargeConvergenceTolerance(stepNumber: System.UInt32, value: System.Double) System.Void
Sets the Charge Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
ANSYSAnalysisSettings.SetChargeConvergenceValue(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Charge Convergence Value for a given solution step.

ANSYSAnalysisSettings.SetChargeConvergenceMinimumReference(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Charge Convergence Minimum Reference for a given solution step.

ANSYSAnalysisSettings.SetEnergyConvergenceType(stepNumber: System.UInt32, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) System.Void

Sets the Energy Convergence Tolerance type for a given solution step.

ANSYSAnalysisSettings.SetEnergyConvergenceTolerance(stepNumber: System.UInt32, value: System.Double) System.Void
Sets the Energy Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
ANSYSAnalysisSettings.SetEnergyConvergenceValue(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Energy Convergence Value for a given solution step.

ANSYSAnalysisSettings.SetEnergyConvergenceMinimumReference(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Energy Convergence Minimum Reference for a given solution step.

ANSYSAnalysisSettings.SetCurrentConvergenceType(stepNumber: System.UInt32, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) System.Void

Sets the Current Convergence Tolerance type for a given solution step.

ANSYSAnalysisSettings.SetCurrentConvergenceTolerance(stepNumber: System.UInt32, value: System.Double) System.Void
Sets the Current Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
ANSYSAnalysisSettings.SetCurrentConvergenceValue(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Current Convergence Value for a given solution step.

ANSYSAnalysisSettings.SetCurrentConvergenceMinimumReference(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Current Convergence Minimum Reference for a given solution step.

ANSYSAnalysisSettings.SetEmagAMPSConvergenceType(stepNumber: System.UInt32, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) System.Void

Sets the EmagAMPS Convergence Tolerance type for a given solution step.

ANSYSAnalysisSettings.SetEmagAMPSConvergenceTolerance(stepNumber: System.UInt32, value: System.Double) System.Void
Sets the EmagAMPS Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
ANSYSAnalysisSettings.SetEmagAMPSConvergenceValue(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the EmagAMPS Convergence Value for a given solution step.

ANSYSAnalysisSettings.SetEmagAMPSConvergenceMinimumReference(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the EmagAMPS Convergence Minimum Reference for a given solution step.

ANSYSAnalysisSettings.SetEmagCSGConvergenceType(stepNumber: System.UInt32, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) System.Void

Sets the EmagCSG Convergence Tolerance type for a given solution step.

ANSYSAnalysisSettings.SetEmagCSGConvergenceTolerance(stepNumber: System.UInt32, value: System.Double) System.Void
Sets the EmagCSG Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
ANSYSAnalysisSettings.SetEmagCSGConvergenceValue(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the EmagCSG Convergence Value for a given solution step.

ANSYSAnalysisSettings.SetEmagCSGConvergenceMinimumReference(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the EmagCSG Convergence Minimum Reference for a given solution step.

ANSYSAnalysisSettings.GetTemperatureConvergenceType(stepNumber: System.UInt32) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType

Gets the Temperature Convergence Tolerance type at a given solution step.

ANSYSAnalysisSettings.GetTemperatureConvergenceTolerance(stepNumber: System.UInt32) System.Double

Gets the Temperature Convergence Tolerance as a percentage at a given solution step.

ANSYSAnalysisSettings.GetTemperatureConvergenceValue(stepNumber: System.UInt32) Ansys.Mechanical.DataModel.Enums.NonLinearValueType

Gets the Temperature Convergence Value at a given solution step.

ANSYSAnalysisSettings.GetTemperatureConvergenceInputValue(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the Temperature Convergence Input Value at a given solution step.

ANSYSAnalysisSettings.GetTemperatureConvergenceMinimumReference(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the Temperature Convergence Minimum Reference at a given solution step.

ANSYSAnalysisSettings.GetHeatConvergenceType(stepNumber: System.UInt32) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType

Gets the Heat Convergence Tolerance type at a given solution step.

ANSYSAnalysisSettings.GetHeatConvergenceTolerance(stepNumber: System.UInt32) System.Double

Gets the Heat Convergence Tolerance as a percentage at a given solution step.

ANSYSAnalysisSettings.GetHeatConvergenceValue(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the Heat Convergence Value at a given solution step.

ANSYSAnalysisSettings.GetHeatConvergenceMinimumReference(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the Heat Convergence Minimum Reference at a given solution step.

ANSYSAnalysisSettings.GetVoltageConvergenceType(stepNumber: System.UInt32) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType

Gets the Voltage Convergence Tolerance type at a given solution step.

ANSYSAnalysisSettings.GetVoltageConvergenceTolerance(stepNumber: System.UInt32) System.Double

Gets the Voltage Convergence Tolerance as a percentage at a given solution step.

ANSYSAnalysisSettings.GetVoltageConvergenceValue(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the Voltage Convergence Value at a given solution step.

ANSYSAnalysisSettings.GetVoltageConvergenceMinimumReference(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the Voltage Convergence Minimum Reference at a given solution step.

ANSYSAnalysisSettings.GetCurrentConvergenceType(stepNumber: System.UInt32) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType

Gets the Current Convergence Tolerance type at a given solution step.

ANSYSAnalysisSettings.GetCurrentConvergenceTolerance(stepNumber: System.UInt32) System.Double

Gets the Current Convergence Tolerance as a percentage at a given solution step.

ANSYSAnalysisSettings.GetCurrentConvergenceValue(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the Current Convergence Value at a given solution step.

ANSYSAnalysisSettings.GetCurrentConvergenceMinimumReference(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the Current Convergence Minimum Reference at a given solution step.

ANSYSAnalysisSettings.GetEmagAMPSConvergenceType(stepNumber: System.UInt32) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType

Gets the EmagAMPS Convergence Tolerance type at a given solution step.

ANSYSAnalysisSettings.GetEmagAMPSConvergenceTolerance(stepNumber: System.UInt32) System.Double

Gets the EmagAMPS Convergence Tolerance as a percentage at a given solution step.

ANSYSAnalysisSettings.GetEmagAMPSConvergenceValue(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the EmagAMPS Convergence Value at a given solution step.

ANSYSAnalysisSettings.GetEmagAMPSConvergenceMinimumReference(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the EmagAMPS Convergence Minimum Reference at a given solution step.

ANSYSAnalysisSettings.GetEmagCSGConvergenceType(stepNumber: System.UInt32) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType

Gets the EmagCSG Convergence Tolerance type at a given solution step.

ANSYSAnalysisSettings.GetEmagCSGConvergenceTolerance(stepNumber: System.UInt32) System.Double

Gets the EmagCSG Convergence Tolerance as a percentage at a given solution step.

ANSYSAnalysisSettings.GetEmagCSGConvergenceValue(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the EmagCSG Convergence Value at a given solution step.

ANSYSAnalysisSettings.GetEmagCSGConvergenceMinimumReference(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the EmagCSG Convergence Minimum Reference at a given solution step.

ANSYSAnalysisSettings.GetEnergyConvergenceType(stepNumber: System.UInt32) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType

Gets the Energy Convergence Tolerance type at a given solution step.

ANSYSAnalysisSettings.GetEnergyConvergenceTolerance(stepNumber: System.UInt32) System.Double

Gets the Energy Convergence Tolerance as a percentage at a given solution step.

ANSYSAnalysisSettings.GetEnergyConvergenceValue(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the Energy Convergence Value at a given solution step.

ANSYSAnalysisSettings.GetEnergyConvergenceMinimumReference(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the Energy Convergence Minimum Reference at a given solution step.

ANSYSAnalysisSettings.GetLineSearch(stepNumber: System.UInt32) Ansys.Mechanical.DataModel.Enums.LineSearchType

Gets the Line Search at a given solution step.

ANSYSAnalysisSettings.SetLineSearch(stepNumber: System.UInt32, value: Ansys.Mechanical.DataModel.Enums.LineSearchType) System.Void

Sets the Line Search for a given solution step.

ANSYSAnalysisSettings.GetStabilization(stepNumber: System.UInt32) Ansys.Mechanical.DataModel.Enums.StabilizationType

Gets the Stabilization at a given solution step.

ANSYSAnalysisSettings.SetStabilization(stepNumber: System.UInt32, value: Ansys.Mechanical.DataModel.Enums.StabilizationType) System.Void

Sets the Stabilization for a given solution step.

ANSYSAnalysisSettings.GetStabilizationMethod(stepNumber: System.UInt32) Ansys.Mechanical.DataModel.Enums.StabilizationMethod

Gets the Stabilization Method at a given solution step.

ANSYSAnalysisSettings.SetStabilizationMethod(stepNumber: System.UInt32, value: Ansys.Mechanical.DataModel.Enums.StabilizationMethod) System.Void

Sets the Stabilization Method for a given solution step.

ANSYSAnalysisSettings.GetStabilizationEnergyDissipationRatio(stepNumber: System.UInt32) System.Double

Gets the Stabilization Energy Dissipation Ratio at a given solution step.

ANSYSAnalysisSettings.SetStabilizationEnergyDissipationRatio(stepNumber: System.UInt32, value: System.Double) System.Void

Sets the Stabilization Energy Dissipation Ratio for a given solution step.

ANSYSAnalysisSettings.GetStabilizationDampingFactor(stepNumber: System.UInt32) System.Double

Gets the Stabilization Damping Factor at a given solution step.

ANSYSAnalysisSettings.SetStabilizationDampingFactor(stepNumber: System.UInt32, value: System.Double) System.Void

Sets the Stabilization Damping Factor for a given solution step.

ANSYSAnalysisSettings.GetStabilizationFirstSubstepOption(stepNumber: System.UInt32) Ansys.Mechanical.DataModel.Enums.StabilizationFirstSubstepOption

Gets the Stabilization First Substep Option at a given solution step.

ANSYSAnalysisSettings.SetStabilizationFirstSubstepOption(stepNumber: System.UInt32, value: Ansys.Mechanical.DataModel.Enums.StabilizationFirstSubstepOption) System.Void

Sets the Stabilization First Substep Option for a given solution step.

ANSYSAnalysisSettings.GetStabilizationForceLimit(stepNumber: System.UInt32) System.Double

Gets the Stabilization Force Limit at a given solution step.

ANSYSAnalysisSettings.SetStabilizationForceLimit(stepNumber: System.UInt32, value: System.Double) System.Void

Sets the Stabilization Force Limit for a given solution step.

ANSYSAnalysisSettings.GetStoreResultsAt(stepNumber: System.UInt32) Ansys.Mechanical.DataModel.Enums.TimePointsOptions

Gets the Store Results At at a given solution step.

ANSYSAnalysisSettings.SetStoreResultsAt(stepNumber: System.UInt32, value: Ansys.Mechanical.DataModel.Enums.TimePointsOptions) System.Void

Sets the Store Results At for a given solution step.

ANSYSAnalysisSettings.GetStoreResulsAtValue(stepNumber: System.UInt32) System.UInt32

Gets the Store Results At Value at a given solution step.

ANSYSAnalysisSettings.SetStoreResulsAtValue(stepNumber: System.UInt32, value: System.UInt32) System.Void

Sets the Store Results At Value for a given solution step.

ANSYSAnalysisSettings.GetDefineBy(stepNumber: System.UInt32) Ansys.Mechanical.DataModel.Enums.TimeStepDefineByType

Gets the Define By at a given solution step.

ANSYSAnalysisSettings.SetDefineBy(stepNumber: System.UInt32, value: Ansys.Mechanical.DataModel.Enums.TimeStepDefineByType) System.Void

Sets the Define By for a given solution step.

ANSYSAnalysisSettings.GetCarryOverTimeStep(stepNumber: System.UInt32) System.Boolean

Gets the Carry Over Time Step at a given solution step.

ANSYSAnalysisSettings.SetCarryOverTimeStep(stepNumber: System.UInt32, value: System.Boolean) System.Void

Sets the Carry Over Time Step for a given solution step.

ANSYSAnalysisSettings.GetInitialTimeStep(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the Initial Time Step at a given solution step.

ANSYSAnalysisSettings.SetInitialTimeStep(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Initial Time Step for a given solution step.

ANSYSAnalysisSettings.GetMinimumTimeStep(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the Minimum Time Step at a given solution step.

ANSYSAnalysisSettings.SetMinimumTimeStep(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Minimum Time Step for a given solution step.

ANSYSAnalysisSettings.GetMaximumTimeStep(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Gets the Maximum Time Step at a given solution step.

ANSYSAnalysisSettings.SetMaximumTimeStep(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Maximum Time Step for a given solution step.

ANSYSAnalysisSettings.GetInitialSubsteps(stepNumber: System.UInt32) System.UInt32

Gets the Initial Substeps at a given solution step.

ANSYSAnalysisSettings.SetInitialSubsteps(stepNumber: System.UInt32, value: System.UInt32) System.Void

Sets the Initial Substeps for a given solution step.

ANSYSAnalysisSettings.GetMinimumSubsteps(stepNumber: System.UInt32) System.UInt32

Gets the Minimum Substeps at a given solution step.

ANSYSAnalysisSettings.SetMinimumSubsteps(stepNumber: System.UInt32, value: System.UInt32) System.Void

Sets the Minimum Substeps for a given solution step.

ANSYSAnalysisSettings.GetMaximumSubsteps(stepNumber: System.UInt32) System.UInt32

Gets the Maximum Substeps at a given solution step.

ANSYSAnalysisSettings.SetMaximumSubsteps(stepNumber: System.UInt32, value: System.UInt32) System.Void

Sets the Maximum Substeps for a given solution step.

ANSYSAnalysisSettings.SetNumberOfSubSteps(stepNumber: System.UInt32, value: System.UInt32) System.Void

Sets the Number of Substeps for a given solution step.

ANSYSAnalysisSettings.GetNumberOfSubSteps(stepNumber: System.UInt32) System.UInt32

Gets the Number of Substeps for a given solution step.

ANSYSAnalysisSettings.SetTimeStep(stepNumber: System.UInt32, value: Ansys.Core.Units.Quantity) System.Void

Sets the Time Step for a given solution step.

ANSYSAnalysisSettings.GetTimeStep(stepNumber: System.UInt32) Ansys.Core.Units.Quantity

Sets the Time Step for a given solution step.

ANSYSAnalysisSettings.SetTimeIntegration(stepNumber: System.UInt32, value: System.Boolean) System.Void

Sets the TimeIntegration for a given solution step.

ANSYSAnalysisSettings.SetStructuralOnly(stepNumber: System.UInt32, value: System.Boolean) System.Void

Sets the TimeIntegration Structural for a given solution step.

ANSYSAnalysisSettings.SetThermalOnly(stepNumber: System.UInt32, value: System.Boolean) System.Void

Sets the TimeIntegration Thermal for a given solution step.

ANSYSAnalysisSettings.GetTimeIntegration(stepNumber: System.UInt32) System.Boolean

Gets the TimeIntegration for a given solution step.

ANSYSAnalysisSettings.GetStructuralOnly(stepNumber: System.UInt32) System.Boolean

Gets the TimeIntegration Structural for a given solution step.

ANSYSAnalysisSettings.GetThermalOnly(stepNumber: System.UInt32) System.Boolean

Sets the TimeIntegration Thermal for a given solution step.

ANSYSAnalysisSettings.GetStepName(stepNumber: System.UInt32) System.String

Gets the Step name at a given step.

ANSYSAnalysisSettings.SetStepName(stepNumber: System.UInt32, value: System.String) System.Void

Sets the Step name at a given step.

ANSYSAnalysisSettings.GetAMStepType(stepNumber: System.UInt32) Ansys.Mechanical.DataModel.Enums.AMProcessStepType

Gets the AM Process Step Type at a given step.

ANSYSAnalysisSettings.CopyTo(other: Ansys.ACT.Automation.Mechanical.DataModelObject) System.Void

CopyTo method.

ANSYSAnalysisSettings.SetCreepEffects(stepNumber: System.UInt32, value: Ansys.Mechanical.DataModel.Enums.Creep) System.Void

Sets the Creep Effects for a given solution step.

ANSYSAnalysisSettings.GetCreepEffects(stepNumber: System.UInt32) Ansys.Mechanical.DataModel.Enums.Creep

Gets the Creep Effects for a given solution step.

ANSYSAnalysisSettings.SetCreepLimitRatio(stepNumber: System.UInt32, value: System.Double) System.Void

Sets the Creep Limit Ratio for a given solution step.

ANSYSAnalysisSettings.GetCreepLimitRatio(stepNumber: System.UInt32) System.Double

Gets the Creep Limit Ratio for a given solution step.

ANSYSAnalysisSettings.DeleteAllRestartPoints() System.Void

DeleteAllRestartPoints method.

ANSYSAnalysisSettings.GetChildren(recurses: System.Boolean, children: System.Collections.Generic.IList[ChildrenType]) System.Collections.Generic.IList[ChildrenType]

Gets the list of children, filtered by type.

ANSYSAnalysisSettings.GetChildren(category: Ansys.Mechanical.DataModel.Enums.DataModelObjectCategory, recurses: System.Boolean, children: System.Collections.Generic.IList[Ansys.Mechanical.DataModel.Interfaces.IDataModelObject]) System.Collections.Generic.IList[Ansys.Mechanical.DataModel.Interfaces.IDataModelObject]

Gets the list of children, filtered by type.

ANSYSAnalysisSettings.AddComment() Ansys.ACT.Automation.Mechanical.Comment

Creates a new child Comment.

ANSYSAnalysisSettings.AddFigure() Ansys.ACT.Automation.Mechanical.Figure

Creates a new child Figure.

ANSYSAnalysisSettings.AddImage(filePath: System.String) Ansys.ACT.Automation.Mechanical.Image
Creates a new child Image.
If a filePath is provided, the image will be loaded from that file,
if not, the image will be a screen capture of the Geometry window.
ANSYSAnalysisSettings.Activate() System.Void

Activate the current object.

ANSYSAnalysisSettings.Duplicate() Ansys.Mechanical.DataModel.Interfaces.IDataModelObject

Creates a copy of the current DataModelObject.

ANSYSAnalysisSettings.GroupAllSimilarChildren() System.Void

Run the GroupAllSimilarChildren action.

ANSYSAnalysisSettings.GroupSimilarObjects() Ansys.ACT.Automation.Mechanical.TreeGroupingFolder

Run the GroupSimilarObjects action.

ANSYSAnalysisSettings.PropertyByName(name: System.String) Ansys.ACT.Automation.Mechanical.Property

Get a property by its unique name.

ANSYSAnalysisSettings.PropertyByAPIName(name: System.String) Ansys.ACT.Automation.Mechanical.Property
Get a property by its API name.
If multiple properties have the same API Name, only the first property with that name will be returned.
ANSYSAnalysisSettings.CreateParameter(propName: System.String) Ansys.ACT.Interfaces.Mechanical.IParameter

Creates a new parameter for a Property.

ANSYSAnalysisSettings.GetParameter(propName: System.String) Ansys.ACT.Interfaces.Mechanical.IParameter

Gets the parameter corresponding to the given property.

ANSYSAnalysisSettings.RemoveParameter(propName: System.String) System.Void

Removes the parameter from the parameter set corresponding to the given property.