EquivalentRadiatedPowerLevelWaterfallDiagram#

class ansys.mechanical.stubs.v242.Ansys.ACT.Automation.Mechanical.Results.FrequencyResponseResults.EquivalentRadiatedPowerLevelWaterfallDiagram#

Bases: object

Defines a EquivalentRadiatedPowerLevelWaterfallDiagram.

Overview#

Activate

Activate the current object.

AddAlert

Creates a new Alert

AddComment

Creates a new child Comment.

AddConvergence

Creates a new Convergence

AddFigure

Creates a new child Figure.

AddImage

Creates a new child Image.

ClearGeneratedData

Run the ClearGeneratedData action.

CopyTo

Copies all visible properties from this object to another.

CreateParameter

CreateParameter method.

CreateResultsAtAllSets

Creates results at all sets for results under a solution.

Delete

Run the Delete action.

Duplicate

Creates a copy of the current DataModelObject.

DuplicateWithoutResults

Run the DuplicateWithoutResults action.

EvaluateAllResults

Run the EvaluateAllResults action.

ExportAnimation

Run the ExportAnimation action.

ExportToTextFile

Run the ExportToTextFile action.

ExportToWAVFile

Run the ExportToWAVFile action.

ExportToXMLFile

Run the ExportToXMLFile action.

FetchRemoteResults

Run the FetchRemoteResult action.

GetChildren

Gets the list of children, filtered by type.

GetParameter

Gets the parameter corresponding to the given property.

GroupAllSimilarChildren

Run the GroupAllSimilarChildren action.

GroupSimilarObjects

Run the GroupSimilarObjects action.

PromoteToNamedSelection

Run the PromoteToNamedSelection action.

PropertyByAPIName

Get a property by its API name.

PropertyByName

Get a property by its unique name.

RemoveParameter

Removes the parameter from the parameter set corresponding to the given property.

RenameBasedOnDefinition

Run the RenameBasedOnDefinition action.

Average

Gets the Average.

By

Gets or sets the By.

CalculateTimeHistory

Gets or sets the CalculateTimeHistory.

Children

Gets the list of children.

CombinationNumber

Gets or sets the Combination Number for a Solution Combination result.

Comments

Gets the list of associated comments.

CoordinateSystem

Gets or sets the Coordinate System.

CrackFrontNumber

Gets or sets the CrackFrontNumber.

DBWeighting

Gets or sets the DBWeighting.

DataModelObjectCategory

Gets the current DataModelObject's category.

DisplayOption

Gets or sets the DisplayOption.

DisplayPanel

Gets or sets the DisplayPanel.

DisplayTime

Gets or sets the DisplayTime.

DpfEvaluation

Gets or sets the DpfEvaluation.

Figures

Gets the list of associated figures.

GlobalIDs

Gets or sets the GlobalIDs.

GraphControlsXAxis

Gets or sets the GraphControlsXAxis.

Identifier

Gets or sets the Identifier.

Images

Gets the list of associated images.

InternalObject

Gets the internal object. For advanced usage only.

IsSolved

Gets the IsSolved.

ItemType

Gets or sets the ItemType.

IterationNumber

Gets the IterationNumber.

LoadStep

Gets the LoadStep.

LoadStepForMaximumOfMaximumValues

Get the Load Step for the maximum of maximum values.

LoadStepForMaximumOfMinimumValues

Get the Load Step for the maximum of minimum values.

LoadStepForMinimumOfMaximumValues

Get the Load Step for the minimum of maximum values.

LoadStepForMinimumOfMinimumValues

Get the Load Step for the minimum of minimum values.

LoadStepNumber

Gets or sets the LoadStepNumber.

Location

Gets or sets the Location.

Maximum

Gets the Maximum.

MaximumOccursOn

Gets the MaximumOccursOn.

MaximumOfMaximumOverTime

Gets the MaximumOfMaximumOverTime.

MaximumOfMinimumOverTime

Gets the MaximumOfMinimumOverTime.

Minimum

Gets the Minimum.

MinimumOccursOn

Gets the MinimumOccursOn.

MinimumOfMaximumOverTime

Gets the MinimumOfMaximumOverTime.

MinimumOfMinimumOverTime

Gets the MinimumOfMinimumOverTime.

NamedSelections

Gets or sets the NamedSelections.

PanelContribution

Gets or sets the PanelContribution.

PanelsToDisplay

Gets or sets the PanelsToDisplay.

Path

Path property.

PlotData

Gets the result table.

Properties

Gets the list of properties for this object.

ScopingMethod

Gets or sets the ScopingMethod.

SetNumber

Gets or sets the Set Number.

SolutionCombinationDriver

Gets or sets the SolutionCombinationDriver.

SolverComponentIDs

Gets or sets the SolverComponentIDs.

Substep

Gets the Substep.

Suppressed

Gets or sets the Suppressed.

Surface

Surface property.

SurfaceCoating

SurfaceCoating property.

Time

Gets the Time.

TimeForMaximumOfMaximumValues

Get the Time for the maximum of maximum values.

TimeForMaximumOfMinimumValues

Get the Time for the maximum of minimum values.

TimeForMinimumOfMaximumValues

Get the Time for the minimum of maximum values.

TimeForMinimumOfMinimumValues

Get the Time for the minimum of minimum values.

VisibleProperties

Gets the list of properties that are visible for this object.

WaterfallShowTextOnMosaic

Gets or sets the Waterfall Mosaic Text Property.

Property detail#

property EquivalentRadiatedPowerLevelWaterfallDiagram.Average: Ansys.Core.Units.Quantity | None#

Gets the Average.

property EquivalentRadiatedPowerLevelWaterfallDiagram.By: Ansys.Mechanical.DataModel.Enums.SetDriverStyle | None#

Gets or sets the By.

property EquivalentRadiatedPowerLevelWaterfallDiagram.CalculateTimeHistory: bool | None#

Gets or sets the CalculateTimeHistory.

property EquivalentRadiatedPowerLevelWaterfallDiagram.Children: List[Ansys.Mechanical.DataModel.Interfaces.IDataModelObject] | None#

Gets the list of children.

property EquivalentRadiatedPowerLevelWaterfallDiagram.CombinationNumber: int | None#

Gets or sets the Combination Number for a Solution Combination result.

property EquivalentRadiatedPowerLevelWaterfallDiagram.Comments: Iterable[Ansys.ACT.Automation.Mechanical.Comment] | None#

Gets the list of associated comments.

property EquivalentRadiatedPowerLevelWaterfallDiagram.CoordinateSystem: Ansys.ACT.Automation.Mechanical.CoordinateSystem | None#

Gets or sets the Coordinate System. Accepts/Returns None for Solution Coordinate System in the general case (if applicable). Accepts/Returns None for Fiber Coordinate System for a result that is sub scoped by ply.

property EquivalentRadiatedPowerLevelWaterfallDiagram.CrackFrontNumber: int | None#

Gets or sets the CrackFrontNumber.

property EquivalentRadiatedPowerLevelWaterfallDiagram.DBWeighting: Ansys.Mechanical.DataModel.Enums.DBWeightingType | None#

Gets or sets the DBWeighting.

property EquivalentRadiatedPowerLevelWaterfallDiagram.DataModelObjectCategory: Ansys.Mechanical.DataModel.Enums.DataModelObjectCategory | None#

Gets the current DataModelObject's category.

property EquivalentRadiatedPowerLevelWaterfallDiagram.DisplayOption: Ansys.Mechanical.DataModel.Enums.ResultAveragingType | None#

Gets or sets the DisplayOption.

property EquivalentRadiatedPowerLevelWaterfallDiagram.DisplayPanel: bool | None#

Gets or sets the DisplayPanel.

property EquivalentRadiatedPowerLevelWaterfallDiagram.DisplayTime: Ansys.Core.Units.Quantity | None#

Gets or sets the DisplayTime.

property EquivalentRadiatedPowerLevelWaterfallDiagram.DpfEvaluation: Ansys.Mechanical.DataModel.Enums.DpfEvaluationType | None#

Gets or sets the DpfEvaluation.

property EquivalentRadiatedPowerLevelWaterfallDiagram.Figures: Iterable[Ansys.ACT.Automation.Mechanical.Figure] | None#

Gets the list of associated figures.

property EquivalentRadiatedPowerLevelWaterfallDiagram.GlobalIDs: str | None#

Gets or sets the GlobalIDs.

property EquivalentRadiatedPowerLevelWaterfallDiagram.GraphControlsXAxis: Ansys.Mechanical.DataModel.Enums.GraphControlsXAxis | None#

Gets or sets the GraphControlsXAxis.

property EquivalentRadiatedPowerLevelWaterfallDiagram.Identifier: str | None#

Gets or sets the Identifier.

property EquivalentRadiatedPowerLevelWaterfallDiagram.Images: Iterable[Ansys.ACT.Automation.Mechanical.Image] | None#

Gets the list of associated images.

property EquivalentRadiatedPowerLevelWaterfallDiagram.InternalObject: Ansys.Common.Interop.DSObjectsAuto.IDSResultAuto | None#

Gets the internal object. For advanced usage only.

property EquivalentRadiatedPowerLevelWaterfallDiagram.IsSolved: bool | None#

Gets the IsSolved.

property EquivalentRadiatedPowerLevelWaterfallDiagram.ItemType: Ansys.Mechanical.DataModel.Enums.ResultFileItemType | None#

Gets or sets the ItemType.

property EquivalentRadiatedPowerLevelWaterfallDiagram.IterationNumber: int | None#

Gets the IterationNumber.

property EquivalentRadiatedPowerLevelWaterfallDiagram.LoadStep: int | None#

Gets the LoadStep.

property EquivalentRadiatedPowerLevelWaterfallDiagram.LoadStepForMaximumOfMaximumValues: int | None#

Get the Load Step for the maximum of maximum values.

property EquivalentRadiatedPowerLevelWaterfallDiagram.LoadStepForMaximumOfMinimumValues: int | None#

Get the Load Step for the maximum of minimum values.

property EquivalentRadiatedPowerLevelWaterfallDiagram.LoadStepForMinimumOfMaximumValues: int | None#

Get the Load Step for the minimum of maximum values.

property EquivalentRadiatedPowerLevelWaterfallDiagram.LoadStepForMinimumOfMinimumValues: int | None#

Get the Load Step for the minimum of minimum values.

property EquivalentRadiatedPowerLevelWaterfallDiagram.LoadStepNumber: int | None#

Gets or sets the LoadStepNumber.

property EquivalentRadiatedPowerLevelWaterfallDiagram.Location: Ansys.ACT.Interfaces.Common.ISelectionInfo | None#

Gets or sets the Location.

property EquivalentRadiatedPowerLevelWaterfallDiagram.Maximum: Ansys.Core.Units.Quantity | None#

Gets the Maximum.

property EquivalentRadiatedPowerLevelWaterfallDiagram.MaximumOccursOn: str | None#

Gets the MaximumOccursOn.

property EquivalentRadiatedPowerLevelWaterfallDiagram.MaximumOfMaximumOverTime: Ansys.Core.Units.Quantity | None#

Gets the MaximumOfMaximumOverTime.

property EquivalentRadiatedPowerLevelWaterfallDiagram.MaximumOfMinimumOverTime: Ansys.Core.Units.Quantity | None#

Gets the MaximumOfMinimumOverTime.

property EquivalentRadiatedPowerLevelWaterfallDiagram.Minimum: Ansys.Core.Units.Quantity | None#

Gets the Minimum.

property EquivalentRadiatedPowerLevelWaterfallDiagram.MinimumOccursOn: str | None#

Gets the MinimumOccursOn.

property EquivalentRadiatedPowerLevelWaterfallDiagram.MinimumOfMaximumOverTime: Ansys.Core.Units.Quantity | None#

Gets the MinimumOfMaximumOverTime.

property EquivalentRadiatedPowerLevelWaterfallDiagram.MinimumOfMinimumOverTime: Ansys.Core.Units.Quantity | None#

Gets the MinimumOfMinimumOverTime.

property EquivalentRadiatedPowerLevelWaterfallDiagram.NamedSelections: Iterable[Ansys.Mechanical.DataModel.Interfaces.IDataModelObject] | None#

Gets or sets the NamedSelections.

property EquivalentRadiatedPowerLevelWaterfallDiagram.PanelContribution: bool | None#

Gets or sets the PanelContribution.

property EquivalentRadiatedPowerLevelWaterfallDiagram.PanelsToDisplay: int | None#

Gets or sets the PanelsToDisplay.

property EquivalentRadiatedPowerLevelWaterfallDiagram.Path: Ansys.ACT.Automation.Mechanical.Path | None#

Path property.

property EquivalentRadiatedPowerLevelWaterfallDiagram.PlotData: Ansys.Mechanical.DataModel.Results.ResultDataTable | None#

Gets the result table.

property EquivalentRadiatedPowerLevelWaterfallDiagram.Properties: tuple[Ansys.ACT.Automation.Mechanical.Property] | None#

Gets the list of properties for this object.

property EquivalentRadiatedPowerLevelWaterfallDiagram.ScopingMethod: Ansys.Mechanical.DataModel.Enums.GeometryDefineByType | None#

Gets or sets the ScopingMethod.

property EquivalentRadiatedPowerLevelWaterfallDiagram.SetNumber: int | None#

Gets or sets the Set Number.

property EquivalentRadiatedPowerLevelWaterfallDiagram.SolutionCombinationDriver: Ansys.Mechanical.DataModel.Enums.SolutionCombinationDriverStyle | None#

Gets or sets the SolutionCombinationDriver.

property EquivalentRadiatedPowerLevelWaterfallDiagram.SolverComponentIDs: str | None#

Gets or sets the SolverComponentIDs.

property EquivalentRadiatedPowerLevelWaterfallDiagram.Substep: int | None#

Gets the Substep.

property EquivalentRadiatedPowerLevelWaterfallDiagram.Suppressed: bool | None#

Gets or sets the Suppressed.

property EquivalentRadiatedPowerLevelWaterfallDiagram.Surface: Ansys.ACT.Automation.Mechanical.Surface | None#

Surface property.

property EquivalentRadiatedPowerLevelWaterfallDiagram.SurfaceCoating: Ansys.ACT.Automation.Mechanical.SurfaceCoating | None#

SurfaceCoating property.

property EquivalentRadiatedPowerLevelWaterfallDiagram.Time: Ansys.Core.Units.Quantity | None#

Gets the Time.

property EquivalentRadiatedPowerLevelWaterfallDiagram.TimeForMaximumOfMaximumValues: Ansys.Core.Units.Quantity | None#

Get the Time for the maximum of maximum values.

property EquivalentRadiatedPowerLevelWaterfallDiagram.TimeForMaximumOfMinimumValues: Ansys.Core.Units.Quantity | None#

Get the Time for the maximum of minimum values.

property EquivalentRadiatedPowerLevelWaterfallDiagram.TimeForMinimumOfMaximumValues: Ansys.Core.Units.Quantity | None#

Get the Time for the minimum of maximum values.

property EquivalentRadiatedPowerLevelWaterfallDiagram.TimeForMinimumOfMinimumValues: Ansys.Core.Units.Quantity | None#

Get the Time for the minimum of minimum values.

property EquivalentRadiatedPowerLevelWaterfallDiagram.VisibleProperties: tuple[Ansys.ACT.Automation.Mechanical.Property] | None#

Gets the list of properties that are visible for this object.

property EquivalentRadiatedPowerLevelWaterfallDiagram.WaterfallShowTextOnMosaic: bool | None#

Gets or sets the Waterfall Mosaic Text Property.

Method detail#

EquivalentRadiatedPowerLevelWaterfallDiagram.Activate() None#

Activate the current object.

EquivalentRadiatedPowerLevelWaterfallDiagram.AddAlert() Ansys.ACT.Automation.Mechanical.Results.Alert#

Creates a new Alert

EquivalentRadiatedPowerLevelWaterfallDiagram.AddComment() Ansys.ACT.Automation.Mechanical.Comment#

Creates a new child Comment.

EquivalentRadiatedPowerLevelWaterfallDiagram.AddConvergence() Ansys.ACT.Automation.Mechanical.Results.Convergence#

Creates a new Convergence

EquivalentRadiatedPowerLevelWaterfallDiagram.AddFigure() Ansys.ACT.Automation.Mechanical.Figure#

Creates a new child Figure.

EquivalentRadiatedPowerLevelWaterfallDiagram.AddImage(filePath: str) Ansys.ACT.Automation.Mechanical.Image#
Creates a new child Image.
If a filePath is provided, the image will be loaded from that file,
if not, the image will be a screen capture of the Geometry window.
EquivalentRadiatedPowerLevelWaterfallDiagram.ClearGeneratedData() None#

Run the ClearGeneratedData action.

EquivalentRadiatedPowerLevelWaterfallDiagram.CopyTo(other: Ansys.ACT.Automation.Mechanical.DataModelObject) None#

Copies all visible properties from this object to another.

EquivalentRadiatedPowerLevelWaterfallDiagram.CreateParameter(propName: str) Ansys.ACT.Interfaces.Mechanical.IParameter#

CreateParameter method.

EquivalentRadiatedPowerLevelWaterfallDiagram.CreateResultsAtAllSets() List[Ansys.Mechanical.DataModel.Interfaces.IDataModelObject]#

Creates results at all sets for results under a solution.

EquivalentRadiatedPowerLevelWaterfallDiagram.Delete() None#

Run the Delete action.

EquivalentRadiatedPowerLevelWaterfallDiagram.Duplicate() Ansys.Mechanical.DataModel.Interfaces.IDataModelObject#

Creates a copy of the current DataModelObject.

EquivalentRadiatedPowerLevelWaterfallDiagram.DuplicateWithoutResults() Ansys.Mechanical.DataModel.Interfaces.IDataModelObject#

Run the DuplicateWithoutResults action.

EquivalentRadiatedPowerLevelWaterfallDiagram.EvaluateAllResults() None#

Run the EvaluateAllResults action.

EquivalentRadiatedPowerLevelWaterfallDiagram.ExportAnimation(filePath: str, format: Ansys.Mechanical.DataModel.Enums.GraphicsAnimationExportFormat, settings: Ansys.Mechanical.Graphics.AnimationExportSettings) None#

Run the ExportAnimation action.

EquivalentRadiatedPowerLevelWaterfallDiagram.ExportToTextFile(filePath: str) None#

Run the ExportToTextFile action.

EquivalentRadiatedPowerLevelWaterfallDiagram.ExportToWAVFile(filePath: str) None#

Run the ExportToWAVFile action.

EquivalentRadiatedPowerLevelWaterfallDiagram.ExportToXMLFile(filePath: str) None#

Run the ExportToXMLFile action.

EquivalentRadiatedPowerLevelWaterfallDiagram.FetchRemoteResults() None#

Run the FetchRemoteResult action.

EquivalentRadiatedPowerLevelWaterfallDiagram.GetChildren(recurses: bool, children: List[ChildrenType]) List[ChildrenType]#

Gets the list of children, filtered by type.

EquivalentRadiatedPowerLevelWaterfallDiagram.GetParameter(propName: str) Ansys.ACT.Interfaces.Mechanical.IParameter#

Gets the parameter corresponding to the given property.

EquivalentRadiatedPowerLevelWaterfallDiagram.GroupAllSimilarChildren() None#

Run the GroupAllSimilarChildren action.

EquivalentRadiatedPowerLevelWaterfallDiagram.GroupSimilarObjects() Ansys.ACT.Automation.Mechanical.TreeGroupingFolder#

Run the GroupSimilarObjects action.

EquivalentRadiatedPowerLevelWaterfallDiagram.PromoteToNamedSelection() Iterable[Ansys.ACT.Automation.Mechanical.NamedSelection]#

Run the PromoteToNamedSelection action.

EquivalentRadiatedPowerLevelWaterfallDiagram.PropertyByAPIName(name: str) Ansys.ACT.Automation.Mechanical.Property#
Get a property by its API name.
If multiple properties have the same API Name, only the first property with that name will be returned.
EquivalentRadiatedPowerLevelWaterfallDiagram.PropertyByName(name: str) Ansys.ACT.Automation.Mechanical.Property#

Get a property by its unique name.

EquivalentRadiatedPowerLevelWaterfallDiagram.RemoveParameter(propName: str) None#

Removes the parameter from the parameter set corresponding to the given property.

EquivalentRadiatedPowerLevelWaterfallDiagram.RenameBasedOnDefinition() None#

Run the RenameBasedOnDefinition action.