Overview#
Activate the current object. |
|
Creates a new child Comment. |
|
Creates a new child Figure. |
|
Creates a new child Image. |
|
CopyTo method. |
|
Creates a new parameter for a Property. |
|
DeleteAllRestartPoints method. |
|
Creates a copy of the current DataModelObject. |
|
Gets the AM Process Step Type at a given step. |
|
Gets the Automatic Time Stepping at a given solution step. |
|
Gets the Carry Over Time Step at a given solution step. |
|
Gets the list of children, filtered by type. |
|
Gets the Creep Effects for a given solution step. |
|
Gets the Creep Limit Ratio for a given solution step. |
|
Gets the Current Convergence Minimum Reference at a given solution step. |
|
Gets the Current Convergence Tolerance as a percentage at a given solution step. |
|
Gets the Current Convergence Tolerance type at a given solution step. |
|
Gets the Current Convergence Value at a given solution step. |
|
Gets the Define By at a given solution step. |
|
Gets the Displacement Convergence Minimum Reference at a given solution step. |
|
Gets the Displacement Convergence Tolerance as a percentage at a given solution step. |
|
Gets the Displacement Convergence Tolerance type at a given solution step. |
|
Gets the Displacement Convergence Value at a given solution step. |
|
Gets the EmagAMPS Convergence Minimum Reference at a given solution step. |
|
Gets the EmagAMPS Convergence Tolerance as a percentage at a given solution step. |
|
Gets the EmagAMPS Convergence Tolerance type at a given solution step. |
|
Gets the EmagAMPS Convergence Value at a given solution step. |
|
Gets the EmagCSG Convergence Minimum Reference at a given solution step. |
|
Gets the EmagCSG Convergence Tolerance as a percentage at a given solution step. |
|
Gets the EmagCSG Convergence Tolerance type at a given solution step. |
|
Gets the EmagCSG Convergence Value at a given solution step. |
|
Gets the Energy Convergence Minimum Reference at a given solution step. |
|
Gets the Energy Convergence Tolerance as a percentage at a given solution step. |
|
Gets the Energy Convergence Tolerance type at a given solution step. |
|
Gets the Energy Convergence Value at a given solution step. |
|
Gets the Force Convergence Minimum Reference at a given solution step. |
|
Gets the Force Convergence Tolerance as a percentage at a given solution step. |
|
Gets the Force Convergence Tolerance Type at a given solution step. |
|
Gets the Force Convergence Value at a given solution step. |
|
Gets the Heat Convergence Minimum Reference at a given solution step. |
|
Gets the Heat Convergence Tolerance as a percentage at a given solution step. |
|
Gets the Heat Convergence Tolerance type at a given solution step. |
|
Gets the Heat Convergence Value at a given solution step. |
|
Gets the Initial Substeps at a given solution step. |
|
Gets the Initial Time Step at a given solution step. |
|
Gets the Line Search at a given solution step. |
|
Gets the Maximum Substeps at a given solution step. |
|
Gets the Maximum Time Step at a given solution step. |
|
Gets the Minimum Substeps at a given solution step. |
|
Gets the Minimum Time Step at a given solution step. |
|
Gets the Moment Convergence Minimum Reference at a given solution step. |
|
Gets the Moment Convergence Tolerance as a percentage at a given solution step. |
|
Gets the Moment Convergence Tolerance type at a given solution step. |
|
Gets the Moment Convergence Value at a given solution step. |
|
Gets the Number of Substeps for a given solution step. |
|
Gets the parameter corresponding to the given property. |
|
Gets the Rotation Convergence Minimum Reference at a given solution step. |
|
Gets the Rotation Convergence Tolerance as a percentage at a given solution step. |
|
Gets the Rotation Convergence Tolerance type at a given solution step. |
|
Gets the Rotation Convergence Value at a given solution step. |
|
Gets the Stabilization at a given solution step. |
|
Gets the Stabilization Damping Factor at a given solution step. |
|
Gets the Stabilization Energy Dissipation Ratio at a given solution step. |
|
Gets the Stabilization First Substep Option at a given solution step. |
|
Gets the Stabilization Force Limit at a given solution step. |
|
Gets the Stabilization Method at a given solution step. |
|
Gets the Step End Time at a given solution step. |
|
Gets the Step name at a given step. |
|
Gets the Store Results At Value at a given solution step. |
|
Gets the Store Results At at a given solution step. |
|
Gets the TimeIntegration Structural for a given solution step. |
|
Gets the Temperature Convergence Input Value at a given solution step. |
|
Gets the Temperature Convergence Minimum Reference at a given solution step. |
|
Gets the Temperature Convergence Tolerance as a percentage at a given solution step. |
|
Gets the Temperature Convergence Tolerance type at a given solution step. |
|
Gets the Temperature Convergence Value at a given solution step. |
|
Sets the TimeIntegration Thermal for a given solution step. |
|
Gets the TimeIntegration for a given solution step. |
|
Sets the Time Step for a given solution step. |
|
Gets the Voltage Convergence Minimum Reference at a given solution step. |
|
Gets the Voltage Convergence Tolerance as a percentage at a given solution step. |
|
Gets the Voltage Convergence Tolerance type at a given solution step. |
|
Gets the Voltage Convergence Value at a given solution step. |
|
Run the GroupAllSimilarChildren action. |
|
Run the GroupSimilarObjects action. |
|
Get a property by its API name. |
|
Get a property by its unique name. |
|
Removes the parameter from the parameter set corresponding to the given property. |
|
Sets the Automatic Time Stepping for a given solution step. |
|
Sets the Carry Over Time Step for a given solution step. |
|
Sets the Charge Convergence Minimum Reference for a given solution step. |
|
Sets the Charge Convergence Tolerance as a percentage for a given solution step. |
|
Sets the Charge Convergence Tolerance type for a given solution step. |
|
Sets the Charge Convergence Value for a given solution step. |
|
Sets the Creep Effects for a given solution step. |
|
Sets the Creep Limit Ratio for a given solution step. |
|
Sets the Current Convergence Minimum Reference for a given solution step. |
|
Sets the Current Convergence Tolerance as a percentage for a given solution step. |
|
Sets the Current Convergence Tolerance type for a given solution step. |
|
Sets the Current Convergence Value for a given solution step. |
|
Sets the Define By for a given solution step. |
|
Sets the Displacement Convergence Minimum Reference for a given solution step. |
|
Sets the Displacement Convergence Tolerance as a percentage for a given solution step. |
|
Sets the Displacement Convergence Tolerance type for a given solution step. |
|
Sets the Displacement Convergence Value for a given solution step. |
|
Sets the EmagAMPS Convergence Minimum Reference for a given solution step. |
|
Sets the EmagAMPS Convergence Tolerance as a percentage for a given solution step. |
|
Sets the EmagAMPS Convergence Tolerance type for a given solution step. |
|
Sets the EmagAMPS Convergence Value for a given solution step. |
|
Sets the EmagCSG Convergence Minimum Reference for a given solution step. |
|
Sets the EmagCSG Convergence Tolerance as a percentage for a given solution step. |
|
Sets the EmagCSG Convergence Tolerance type for a given solution step. |
|
Sets the EmagCSG Convergence Value for a given solution step. |
|
Sets the Energy Convergence Minimum Reference for a given solution step. |
|
Sets the Energy Convergence Tolerance as a percentage for a given solution step. |
|
Sets the Energy Convergence Tolerance type for a given solution step. |
|
Sets the Energy Convergence Value for a given solution step. |
|
Sets the Force Convergence Minimum Reference for a given solution step. |
|
Sets the Force Convergence Tolerance as a percentage for a given solution step. |
|
Sets the Force Convergence Tolerance Type for a given solution step. |
|
Sets the Force Convergence Value for a given solution step. |
|
Sets the Heat Convergence Minimum Reference for a given solution step. |
|
Sets the Heat Convergence Tolerance as a percentage for a given solution step. |
|
Sets the Heat Convergence Tolerance type for a given solution step. |
|
Sets the Heat Convergence Value for a given solution step. |
|
Sets the Initial Substeps for a given solution step. |
|
Sets the Initial Time Step for a given solution step. |
|
Sets the Line Search for a given solution step. |
|
Sets the Maximum Substeps for a given solution step. |
|
Sets the Maximum Time Step for a given solution step. |
|
Sets the Minimum Substeps for a given solution step. |
|
Sets the Minimum Time Step for a given solution step. |
|
Sets the Moment Convergence Minimum Reference for a given solution step. |
|
Sets the Moment Convergence Tolerance as a percentage for a given solution step. |
|
Sets the Moment Convergence Tolerance type for a given solution step. |
|
Sets the Moment Convergence Value for a given solution step. |
|
Sets the Number of Substeps for a given solution step. |
|
Sets the Rotation Convergence Minimum Reference for a given solution step. |
|
Sets the Rotation Convergence Tolerance as a percentage for a given solution step. |
|
Sets the Rotation Convergence Tolerance type for a given solution step. |
|
Sets the Rotation Convergence Value for a given solution step. |
|
Sets the Stabilization for a given solution step. |
|
Sets the Stabilization Damping Factor for a given solution step. |
|
Sets the Stabilization Energy Dissipation Ratio for a given solution step. |
|
Sets the Stabilization First Substep Option for a given solution step. |
|
Sets the Stabilization Force Limit for a given solution step. |
|
Sets the Stabilization Method for a given solution step. |
|
Sets the Step End Time for a given solution step. |
|
Sets the Step name at a given step. |
|
Sets the Store Results At Value for a given solution step. |
|
Sets the Store Results At for a given solution step. |
|
Sets the TimeIntegration Structural for a given solution step. |
|
Sets the Temperature Convergence Input Value for a given solution step. |
|
Sets the Temperature Convergence Minimum Reference for a given solution step. |
|
Sets the Temperature Convergence Tolerance as a percentage for a given solution step. |
|
Sets the Temperature Convergence Tolerance type for a given solution step. |
|
Sets the Temperature Convergence Value for a given solution step. |
|
Sets the TimeIntegration Thermal for a given solution step. |
|
Sets the TimeIntegration for a given solution step. |
|
Sets the Time Step for a given solution step. |
|
Sets the Voltage Convergence Minimum Reference for a given solution step. |
|
Sets the Voltage Convergence Tolerance as a percentage for a given solution step. |
|
Sets the Voltage Convergence Tolerance type for a given solution step. |
|
Sets the Voltage Convergence Value for a given solution step. |
Gets or sets the AM Cooldown Number of Substeps. |
|
Gets or sets the AMPSConvergence. |
|
Gets or sets the AM Process Step Type. |
|
Gets or sets the AM Substeps Between Heating. |
|
Gets or sets the AM Substeps to Apply Heat. |
|
Gets or sets the AggressiveRemeshing. |
|
Gets or sets the AutomaticTimeStepping. |
|
Gets or sets the AxisymmetryDivisions. |
|
Gets or sets the BackStress. |
|
Gets or sets the BaseRemovalType. |
|
Gets or sets the BoundaryAngle. |
|
Gets or sets the CSGConvergence. |
|
Gets or sets the CStarIntegral. |
|
Gets or sets the CacheResultsInMemory. |
|
Gets or sets the CalculateAcceleration. |
|
Gets or sets the CalculateEnergy. |
|
Gets or sets the CalculateEulerAngles. |
|
Gets or sets the CalculateReactions. |
|
Gets or sets the CalculateThermalFlux. |
|
Gets or sets the CalculateVelocity. |
|
Gets or sets the CalculateVelocityAndAcceleration. |
|
Gets or sets the CalculateVolumeEnergy. |
|
Gets or sets the CampbellDiagram. |
|
Gets or sets the CarryOverTimeStep. |
|
Gets or sets the CentralFrequency. |
|
Gets or sets the ChargeConvergence. |
|
Gets or sets the ChargeConvergenceMinimumReference. |
|
Gets or sets the ChargeConvergenceTolerance. |
|
Gets or sets the ChargeConvergenceValue. |
|
Gets the list of children. |
|
Gets or sets the ClusterNumber. |
|
Gets or sets the ClusterResults. |
|
Gets or sets the CombineRestartFiles. |
|
Gets the list of associated comments. |
|
Gets or sets the ConstantDamping. |
|
Gets or sets the ConstantDampingRatio. |
|
Gets or sets the ContactData. |
|
Gets or sets the ContactMiscellaneous. |
|
Gets or sets the ContactSplit. |
|
Gets or sets the ContactSplitMaxNum. |
|
Gets or sets the ContactSummary. |
|
Gets or sets the AM Cooldown Time. |
|
Gets or sets the AM Cooldown Time Type. |
|
Gets or sets the CoriolisEffectApplied. |
|
Gets or sets the CreepEffects. |
|
Gets or sets the CreepLimitRatio. |
|
Gets or sets the CurrentConvergence. |
|
Gets or sets the CurrentConvergenceMinimumReference. |
|
Gets or sets the CurrentConvergenceTolerance. |
|
Gets or sets the CurrentConvergenceValue. |
|
Gets or sets the Current Restart Point. |
|
Gets or sets the CurrentStepNumber. |
|
Gets or sets the CurrentStepNumberHarmonic. |
|
Gets or sets the CyclicModeSuperposition. |
|
Gets or sets the Damped. |
|
Gets or sets the DampingDefineBy. |
|
Gets or sets the DampingRatio. |
|
Gets the current DataModelObject's category. |
|
Gets or sets the DefineBy. |
|
Gets or sets the DeleteUnneededFiles. |
|
Gets or sets the DisplacementConvergence. |
|
Gets or sets the DisplacementConvergenceMinimumReference. |
|
Gets or sets the DisplacementConvergenceTolerance. |
|
Gets or sets the DisplacementConvergenceValue. |
|
Gets or sets the EdgeSplittingAngle. |
|
Gets or sets the ElectricOnly. |
|
Gets or sets the ElectromagneticNodalForces. |
|
Gets or sets the ElementCurrentDensity. |
|
Gets or sets the EmagAMPSConvergenceMinimumReference. |
|
Gets or sets the EmagAMPSConvergenceTolerance. |
|
Gets or sets the EmagAMPSConvergenceValue. |
|
Gets or sets the EmagCSGConvergenceMinimumReference. |
|
Gets or sets the EmagCSGConvergenceTolerance. |
|
Gets or sets the EmagCSGConvergenceValue. |
|
Gets or sets the EnergyConvergence. |
|
Gets or sets the EnergyConvergenceMinimumReference. |
|
Gets or sets the EnergyConvergenceTolerance. |
|
Gets or sets the EnergyConvergenceValue. |
|
Gets or sets the EngineOrderofExcitation. |
|
Gets or sets the EqvDampingRatioFromModal. |
|
Gets or sets the ExcludeInsignificantModes. |
|
Gets or sets the ExpandResultsFrom. |
|
Gets the Expansion. |
|
Gets or sets the ExportHighStrains. |
|
Gets or sets the ExportLayerEndTemperature. |
|
Gets or sets the ExportRecoaterInterference. |
|
Gets or sets the FarFieldRadiationSurface. |
|
Gets or sets the FieldIntensityandFluxDensity. |
|
Gets the list of associated figures. |
|
Gets or sets the FluxConvergence. |
|
Gets or sets the ForceConvergence. |
|
Gets or sets the ForceConvergenceMinimumReference. |
|
Gets or sets the ForceConvergenceTolerance. |
|
Gets or sets the ForceConvergenceValue. |
|
Gets or sets the FractureSolverControls. |
|
Gets or sets the Frequency. |
|
Gets or sets the FrequencySpacing. |
|
Gets or sets the FutureAnalysis. |
|
Gets or sets the GeneralMiscellaneous. |
|
Gets or sets the GeneralMiscellaneousOption. |
|
Gets or sets the GenerateMeshRestartPoints. |
|
Gets or sets the GenerateRestartPoints. |
|
Gets or sets the GlobalSizeRatioQualityImprovement. |
|
Gets or sets the GlobalSizeRatioQualityRefinement. |
|
Graph property. |
|
Gets or sets the HarmonicIndexInterval. |
|
Gets or sets the HarmonicIndexRange. |
|
Gets or sets the HarmonicOrders. |
|
Gets or sets the HeatConvergence. |
|
Gets or sets the HeatConvergenceMinimumReference. |
|
Gets or sets the HeatConvergenceTolerance. |
|
Gets or sets the HeatConvergenceValue. |
|
Gets or sets the HeatGenerationRate. |
|
Gets or sets the HemicubeResolution. |
|
Gets or sets the IgnoreAcousticDamping. |
|
Gets the list of associated images. |
|
Gets or sets the IncludeNegativeLoadMultiplier. |
|
Gets or sets the IncludeResidualVector. |
|
Gets or sets the InertiaRelief. |
|
Gets or sets the InitialSubsteps. |
|
Gets or sets the InitialTimeStep. |
|
Gets the internal object. For advanced usage only. |
|
Gets or sets the InverseOption. |
|
Gets or sets the InverseOptionEndStep. |
|
Gets or sets the JIntegral. |
|
Gets or sets the KeepModalResults. |
|
Gets or sets the KeepPreStressLoadPattern. |
|
Gets or sets the KrylovResidualTolerance. |
|
Gets or sets the KrylovSubspaceDimension. |
|
Gets or sets the KrylovSubspaceFrequency. |
|
Gets or sets the LargeDeflection. |
|
Gets or sets the AM Layers to Build. |
|
Gets or sets the LimitSearchToRange. |
|
Gets or sets the LineSearch. |
|
Gets or sets the LoadStepValue. |
|
Gets or sets the MassCoefficient. |
|
Gets or sets the MaterialForce. |
|
Gets or sets the MaximumHarmonicIndex. |
|
Gets or sets the MaximumIteration. |
|
Gets or sets the MaximumModesToFind. |
|
Gets or sets the MaximumPointsToSavePerStep. |
|
Gets or sets the MaximumSubsteps. |
|
Gets or sets the MaximumTimeStep. |
|
Gets or sets the MeshLoadStepValue. |
|
Gets or sets the MeshRetainFilesAfterFullSolve. |
|
Gets or sets the MeshSaveAtLoadStep. |
|
Gets or sets the MeshSaveAtSubstep. |
|
Gets or sets the Minimum Element Size property for Geometry Based Adaptivity. |
|
Gets or sets the MinimumHarmonicIndex. |
|
Gets or sets the MinimumSubsteps. |
|
Gets or sets the MinimumTimeStep. |
|
Gets or sets the ModalFrequencyRange. |
|
Gets or sets the ModalNumberOfPoints. |
|
Gets or sets the ModalRangeMaximum. |
|
Gets or sets the ModalRangeMinimum. |
|
Gets or sets the ModeReuse. |
|
Gets or sets the ModeSelectionMethod. |
|
Gets or sets the ModeSignificanceLevel. |
|
Gets or sets the ModesCombinationType. |
|
Gets or sets the MomentConvergence. |
|
Gets or sets the MomentConvergenceMinimumReference. |
|
Gets or sets the MomentConvergenceTolerance. |
|
Gets or sets the MomentConvergenceValue. |
|
Gets or sets the Multistep. |
|
Gets or sets the MultistepType. |
|
Gets or sets the NewtonRaphsonOption. |
|
Gets or sets the NodalForces. |
|
Gets or sets the NonLinearFormulation. |
|
Gets the NonLinearSolution. |
|
Gets or sets the NonlinearData. |
|
Gets or sets the NumLoadVectors. |
|
Gets or sets the NumberOfModesToUse. |
|
Gets or sets the NumberOfRPMs. |
|
Gets Number of Restart Points. |
|
Gets or sets the NumberOfSculptedLayersQualityImprovement. |
|
Gets or sets the NumberOfSculptedLayersRefinement. |
|
Gets or sets the NumberOfSteps. |
|
Gets or sets the NumberOfSubSteps. |
|
Gets or sets the NumberOfZones. |
|
Gets or sets the NumericalDamping. |
|
Gets or sets the NumericalDampingValue. |
|
Gets or sets the OnDemandExpansionOption. |
|
Gets or sets the OverRelaxation. |
|
Gets or sets the ParticipationFactor. |
|
Gets or sets the ProjectToGeometry. |
|
Gets the list of properties for this object. |
|
Gets or sets the QuasiStaticSolution. |
|
Gets or sets the RadiositySolver. |
|
Gets or sets the Range Maximum property in Options group of Analysis Settings in Harmonic Analysis. |
|
Gets or sets the Range Minimum property in Options group of Analysis Settings in Harmonic Analysis. |
|
Gets or sets the AM Reference Temperature. |
|
Gets or sets the AM Reference Temperature Type. |
|
Gets or sets the RefinementAlgorithm. |
|
Gets or sets the ReformulationTolerance. |
|
Gets or sets the RelaxationTemperature. |
|
Gets or sets the AM Relaxation Temperature Type. |
|
Gets or sets the RemeshingGradient. |
|
Gets or sets the RemeshingToleranceQualityImprovement. |
|
Gets or sets the RemeshingToleranceRefinement. |
|
Gets or sets the RemovalDirection. |
|
Gets or sets the RemovalStepSize. |
|
Gets the RestartAtLoadStep. |
|
Gets the RestartAtSubstep. |
|
Gets the RestartAtTime. |
|
Gets or sets the RestartType. |
|
Gets or sets the ResultFileCompression. |
|
Gets or sets the RetainFilesAfterFullSolve. |
|
Gets or sets the RetainModesymFileAfterSolve. |
|
Gets or sets the RotationConvergence. |
|
Gets or sets the RotationConvergenceMinimumReference. |
|
Gets or sets the RotationConvergenceTolerance. |
|
Gets or sets the RpmCentralFrequency. |
|
Gets or sets the RpmClusterNumber. |
|
Gets or sets the RpmFrequencySpacing. |
|
Gets or sets the RpmRangeMaximum. |
|
Gets or sets the RpmRangeMinimum. |
|
Gets or sets the RpmSolutionIntervals. |
|
Gets or sets the RpmValue. |
|
Gets or sets the SIFS. |
|
Gets or sets the SaveAtLoadStep. |
|
Gets or sets the SaveAtSubstep. |
|
Gets or sets the SaveMAPDLDB. |
|
Gets or sets the SaveSpecifiedLoadStep. |
|
Gets or sets the ScatteredFieldFormulation. |
|
Gets or sets the ScatteringOutputType. |
|
Gets the ScratchSolverFilesDirectory. |
|
Gets or sets the Range Maximum property in Options group of Analysis Settings in Modal Analysis. |
|
Gets or sets the Range Minimum property in Options group of Analysis Settings in Modal Analysis. |
|
Gets or sets the SignificanceThreshold. |
|
Gets or sets the SolutionIntervals. |
|
Gets or sets the SolutionMethod. |
|
Gets the SolverFilesDirectory. |
|
Gets or sets the SolverPivotChecking. |
|
Gets or sets the SolverTolerance. |
|
Gets or sets the SolverType. |
|
Gets or sets the SolverUnitSystem. |
|
Gets or sets the SolverUnits. |
|
Gets or sets the SpectrumType. |
|
Gets or sets the SpinSoftening. |
|
Gets or sets the SpringStiffness. |
|
Gets or sets the SpringStiffnessFactor. |
|
Gets or sets the SpringStiffnessValue. |
|
Gets or sets the Stabilization. |
|
Gets or sets the StabilizationActivationForFirstSubstep. |
|
Gets or sets the StabilizationDampingFactor. |
|
Gets or sets the StabilizationEnergyDissipationRatio. |
|
Gets or sets the StabilizationForceLimit. |
|
Gets or sets the StabilizationMethod. |
|
Gets or sets the StepEndTime. |
|
Gets or sets the Step Name. |
|
Gets or sets the StiffnessCoefficient. |
|
Gets or sets the StiffnessCoefficientDefineBy. |
|
Gets or sets the StoreComplexSolution. |
|
Gets or sets the StoreModalResults. |
|
Gets or sets the StoreResulsAtValue. |
|
Gets or sets the StoreResultsAt. |
|
Gets or sets the StoreResultsAtAllFrequencies. |
|
Gets or sets the Strain. |
|
Gets or sets the Stress. |
|
Gets or sets the StructuralDampingCoefficient. |
|
Gets or sets the StructuralOnly. |
|
Gets or sets the TStress. |
|
Gets or sets the TemperatureConvergence. |
|
Gets or sets the TemperatureConvergenceInputValue. |
|
Gets or sets the TemperatureConvergenceMinimumReference. |
|
Gets or sets the TemperatureConvergenceTolerance. |
|
Gets or sets the TemperatureConvergenceValue. |
|
Gets or sets the ThermalOnly. |
|
Gets or sets the TimeIntegration. |
|
Gets or sets the TimeStep. |
|
Gets or sets the TransientApplication. |
|
Gets or sets the TransientApplicationUserDefined. |
|
Gets or sets the UserDefinedFrequencies. |
|
Gets or sets the UserDefinedFrequencySteps. |
|
Gets or sets the ViewFactorMethod. |
|
Gets the list of properties that are visible for this object. |
|
Gets or sets the VoltageConvergence. |
|
Gets or sets the VoltageConvergenceMinimumReference. |
|
Gets or sets the VoltageConvergenceTolerance. |
|
Gets or sets the VoltageConvergenceValue. |
|
Gets or sets the WeakSprings. |
Property detail#
- property ANSYSAnalysisSettings.AMCooldownNumberOfSubsteps: int | None#
Gets or sets the AM Cooldown Number of Substeps.
- property ANSYSAnalysisSettings.AMPSConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the AMPSConvergence.
- property ANSYSAnalysisSettings.AMStepType: Ansys.Mechanical.DataModel.Enums.AMProcessStepType | None#
Gets or sets the AM Process Step Type.
- property ANSYSAnalysisSettings.AMSubstepsBetweenHeating: int | None#
Gets or sets the AM Substeps Between Heating.
- property ANSYSAnalysisSettings.AMSubstepsToApplyHeats: int | None#
Gets or sets the AM Substeps to Apply Heat.
- property ANSYSAnalysisSettings.AggressiveRemeshing: bool | None#
Gets or sets the AggressiveRemeshing.
- property ANSYSAnalysisSettings.AutomaticTimeStepping: Ansys.Mechanical.DataModel.Enums.AutomaticTimeStepping | None#
Gets or sets the AutomaticTimeStepping.
- property ANSYSAnalysisSettings.AxisymmetryDivisions: int | None#
Gets or sets the AxisymmetryDivisions.
- property ANSYSAnalysisSettings.BaseRemovalType: Ansys.Mechanical.DataModel.Enums.AMBaseRemovalType | None#
Gets or sets the BaseRemovalType.
- property ANSYSAnalysisSettings.BoundaryAngle: Ansys.Core.Units.Quantity | None#
Gets or sets the BoundaryAngle.
- property ANSYSAnalysisSettings.CSGConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the CSGConvergence.
- property ANSYSAnalysisSettings.CacheResultsInMemory: Ansys.Mechanical.DataModel.Enums.CacheResultsInMemory | None#
Gets or sets the CacheResultsInMemory.
- property ANSYSAnalysisSettings.CalculateAcceleration: bool | None#
Gets or sets the CalculateAcceleration.
- property ANSYSAnalysisSettings.CalculateEulerAngles: bool | None#
Gets or sets the CalculateEulerAngles.
- property ANSYSAnalysisSettings.CalculateReactions: bool | None#
Gets or sets the CalculateReactions.
- property ANSYSAnalysisSettings.CalculateThermalFlux: bool | None#
Gets or sets the CalculateThermalFlux.
- property ANSYSAnalysisSettings.CalculateVelocityAndAcceleration: bool | None#
Gets or sets the CalculateVelocityAndAcceleration.
- property ANSYSAnalysisSettings.CalculateVolumeEnergy: bool | None#
Gets or sets the CalculateVolumeEnergy.
- property ANSYSAnalysisSettings.CentralFrequency: Ansys.Core.Units.Quantity | None#
Gets or sets the CentralFrequency.
- property ANSYSAnalysisSettings.ChargeConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the ChargeConvergence.
- property ANSYSAnalysisSettings.ChargeConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the ChargeConvergenceMinimumReference.
- property ANSYSAnalysisSettings.ChargeConvergenceTolerance: float | None#
Gets or sets the ChargeConvergenceTolerance.
- property ANSYSAnalysisSettings.ChargeConvergenceValue: Ansys.Core.Units.Quantity | None#
Gets or sets the ChargeConvergenceValue.
- property ANSYSAnalysisSettings.Children: List[Ansys.Mechanical.DataModel.Interfaces.IDataModelObject] | None#
Gets the list of children.
- property ANSYSAnalysisSettings.CombineRestartFiles: Ansys.Mechanical.DataModel.Enums.CombineRestartFilesType | None#
Gets or sets the CombineRestartFiles.
- property ANSYSAnalysisSettings.Comments: Iterable[Ansys.ACT.Automation.Mechanical.Comment] | None#
Gets the list of associated comments.
- property ANSYSAnalysisSettings.ConstantDamping: Ansys.Mechanical.DataModel.Enums.ConstantDampingType | None#
Gets or sets the ConstantDamping.
- property ANSYSAnalysisSettings.ConstantDampingRatio: float | None#
Gets or sets the ConstantDampingRatio.
- property ANSYSAnalysisSettings.ContactMiscellaneous: bool | None#
Gets or sets the ContactMiscellaneous.
- property ANSYSAnalysisSettings.ContactSplit: Ansys.Mechanical.DataModel.Enums.ContactSplitType | None#
Gets or sets the ContactSplit.
- property ANSYSAnalysisSettings.ContactSummary: Ansys.Mechanical.DataModel.Enums.ContactSummaryType | None#
Gets or sets the ContactSummary.
- property ANSYSAnalysisSettings.CooldownTime: Ansys.Core.Units.Quantity | None#
Gets or sets the AM Cooldown Time.
- property ANSYSAnalysisSettings.CooldownTimeType: Ansys.Mechanical.DataModel.Enums.AMCooldownTimeType | None#
Gets or sets the AM Cooldown Time Type.
- property ANSYSAnalysisSettings.CoriolisEffectApplied: Ansys.Mechanical.DataModel.Enums.CoriolisEffectType | None#
Gets or sets the CoriolisEffectApplied.
- property ANSYSAnalysisSettings.CreepEffects: Ansys.Mechanical.DataModel.Enums.Creep | None#
Gets or sets the CreepEffects.
- property ANSYSAnalysisSettings.CurrentConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the CurrentConvergence.
- property ANSYSAnalysisSettings.CurrentConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the CurrentConvergenceMinimumReference.
- property ANSYSAnalysisSettings.CurrentConvergenceTolerance: float | None#
Gets or sets the CurrentConvergenceTolerance.
- property ANSYSAnalysisSettings.CurrentConvergenceValue: Ansys.Core.Units.Quantity | None#
Gets or sets the CurrentConvergenceValue.
- property ANSYSAnalysisSettings.CurrentRestartPoint: int | None#
Gets or sets the Current Restart Point.
- property ANSYSAnalysisSettings.CurrentStepNumberHarmonic: int | None#
Gets or sets the CurrentStepNumberHarmonic.
- property ANSYSAnalysisSettings.CyclicModeSuperposition: bool | None#
Gets or sets the CyclicModeSuperposition.
- property ANSYSAnalysisSettings.DampingDefineBy: Ansys.Mechanical.DataModel.Enums.DampingDefineBy | None#
Gets or sets the DampingDefineBy.
- property ANSYSAnalysisSettings.DataModelObjectCategory: Ansys.Mechanical.DataModel.Enums.DataModelObjectCategory | None#
Gets the current DataModelObject's category.
- property ANSYSAnalysisSettings.DefineBy: Ansys.Mechanical.DataModel.Enums.TimeStepDefineByType | None#
Gets or sets the DefineBy.
- property ANSYSAnalysisSettings.DeleteUnneededFiles: bool | None#
Gets or sets the DeleteUnneededFiles.
- property ANSYSAnalysisSettings.DisplacementConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the DisplacementConvergence.
- property ANSYSAnalysisSettings.DisplacementConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the DisplacementConvergenceMinimumReference.
- property ANSYSAnalysisSettings.DisplacementConvergenceTolerance: Ansys.Core.Units.Quantity | None#
Gets or sets the DisplacementConvergenceTolerance.
- property ANSYSAnalysisSettings.DisplacementConvergenceValue: Ansys.Core.Units.Quantity | None#
Gets or sets the DisplacementConvergenceValue.
- property ANSYSAnalysisSettings.EdgeSplittingAngle: Ansys.Core.Units.Quantity | None#
Gets or sets the EdgeSplittingAngle.
- property ANSYSAnalysisSettings.ElectromagneticNodalForces: bool | None#
Gets or sets the ElectromagneticNodalForces.
- property ANSYSAnalysisSettings.ElementCurrentDensity: bool | None#
Gets or sets the ElementCurrentDensity.
- property ANSYSAnalysisSettings.EmagAMPSConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the EmagAMPSConvergenceMinimumReference.
- property ANSYSAnalysisSettings.EmagAMPSConvergenceTolerance: float | None#
Gets or sets the EmagAMPSConvergenceTolerance.
- property ANSYSAnalysisSettings.EmagAMPSConvergenceValue: Ansys.Core.Units.Quantity | None#
Gets or sets the EmagAMPSConvergenceValue.
- property ANSYSAnalysisSettings.EmagCSGConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the EmagCSGConvergenceMinimumReference.
- property ANSYSAnalysisSettings.EmagCSGConvergenceTolerance: float | None#
Gets or sets the EmagCSGConvergenceTolerance.
- property ANSYSAnalysisSettings.EmagCSGConvergenceValue: Ansys.Core.Units.Quantity | None#
Gets or sets the EmagCSGConvergenceValue.
- property ANSYSAnalysisSettings.EnergyConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the EnergyConvergence.
- property ANSYSAnalysisSettings.EnergyConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the EnergyConvergenceMinimumReference.
- property ANSYSAnalysisSettings.EnergyConvergenceTolerance: float | None#
Gets or sets the EnergyConvergenceTolerance.
- property ANSYSAnalysisSettings.EnergyConvergenceValue: Ansys.Core.Units.Quantity | None#
Gets or sets the EnergyConvergenceValue.
- property ANSYSAnalysisSettings.EngineOrderofExcitation: int | None#
Gets or sets the EngineOrderofExcitation.
- property ANSYSAnalysisSettings.EqvDampingRatioFromModal: bool | None#
Gets or sets the EqvDampingRatioFromModal.
- property ANSYSAnalysisSettings.ExcludeInsignificantModes: bool | None#
Gets or sets the ExcludeInsignificantModes.
- property ANSYSAnalysisSettings.ExpandResultsFrom: Ansys.Mechanical.DataModel.Enums.ExpandResultFrom | None#
Gets or sets the ExpandResultsFrom.
- property ANSYSAnalysisSettings.Expansion: Ansys.Mechanical.DataModel.Enums.ExpandResultsSubType | None#
Gets the Expansion.
- property ANSYSAnalysisSettings.ExportLayerEndTemperature: bool | None#
Gets or sets the ExportLayerEndTemperature.
- property ANSYSAnalysisSettings.ExportRecoaterInterference: bool | None#
Gets or sets the ExportRecoaterInterference.
- property ANSYSAnalysisSettings.FarFieldRadiationSurface: Ansys.Mechanical.DataModel.Enums.FarFieldRadiationSurfaceType | None#
Gets or sets the FarFieldRadiationSurface.
- property ANSYSAnalysisSettings.FieldIntensityandFluxDensity: bool | None#
Gets or sets the FieldIntensityandFluxDensity.
- property ANSYSAnalysisSettings.Figures: Iterable[Ansys.ACT.Automation.Mechanical.Figure] | None#
Gets the list of associated figures.
- property ANSYSAnalysisSettings.ForceConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the ForceConvergence.
- property ANSYSAnalysisSettings.ForceConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the ForceConvergenceMinimumReference.
- property ANSYSAnalysisSettings.ForceConvergenceTolerance: Ansys.Core.Units.Quantity | None#
Gets or sets the ForceConvergenceTolerance.
- property ANSYSAnalysisSettings.ForceConvergenceValue: Ansys.Core.Units.Quantity | None#
Gets or sets the ForceConvergenceValue.
- property ANSYSAnalysisSettings.FractureSolverControls: bool | None#
Gets or sets the FractureSolverControls.
- property ANSYSAnalysisSettings.Frequency: Ansys.Core.Units.Quantity | None#
Gets or sets the Frequency.
- property ANSYSAnalysisSettings.FrequencySpacing: Ansys.Mechanical.DataModel.Enums.FrequencySpacingType | None#
Gets or sets the FrequencySpacing.
- property ANSYSAnalysisSettings.FutureAnalysis: Ansys.Mechanical.DataModel.Enums.FutureIntentType | None#
Gets or sets the FutureAnalysis.
- property ANSYSAnalysisSettings.GeneralMiscellaneous: bool | None#
Gets or sets the GeneralMiscellaneous.
- property ANSYSAnalysisSettings.GeneralMiscellaneousOption: Ansys.Mechanical.DataModel.Enums.GeneralMiscellaneousOptionType | None#
Gets or sets the GeneralMiscellaneousOption.
- property ANSYSAnalysisSettings.GenerateMeshRestartPoints: Ansys.Mechanical.DataModel.Enums.MeshRestartControlsType | None#
Gets or sets the GenerateMeshRestartPoints.
- property ANSYSAnalysisSettings.GenerateRestartPoints: Ansys.Mechanical.DataModel.Enums.RestartControlsType | None#
Gets or sets the GenerateRestartPoints.
- property ANSYSAnalysisSettings.GlobalSizeRatioQualityImprovement: float | None#
Gets or sets the GlobalSizeRatioQualityImprovement.
- property ANSYSAnalysisSettings.GlobalSizeRatioQualityRefinement: float | None#
Gets or sets the GlobalSizeRatioQualityRefinement.
- property ANSYSAnalysisSettings.Graph: Ansys.Mechanical.Graphics.AnalysisSettingsGraph | None#
Graph property.
- property ANSYSAnalysisSettings.HarmonicIndexInterval: int | None#
Gets or sets the HarmonicIndexInterval.
- property ANSYSAnalysisSettings.HarmonicIndexRange: Ansys.Mechanical.DataModel.Enums.CyclicHarmonicIndex | None#
Gets or sets the HarmonicIndexRange.
- property ANSYSAnalysisSettings.HeatConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the HeatConvergence.
- property ANSYSAnalysisSettings.HeatConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the HeatConvergenceMinimumReference.
- property ANSYSAnalysisSettings.HeatConvergenceTolerance: float | None#
Gets or sets the HeatConvergenceTolerance.
- property ANSYSAnalysisSettings.HeatConvergenceValue: Ansys.Core.Units.Quantity | None#
Gets or sets the HeatConvergenceValue.
- property ANSYSAnalysisSettings.HeatGenerationRate: bool | None#
Gets or sets the HeatGenerationRate.
- property ANSYSAnalysisSettings.IgnoreAcousticDamping: bool | None#
Gets or sets the IgnoreAcousticDamping.
- property ANSYSAnalysisSettings.Images: Iterable[Ansys.ACT.Automation.Mechanical.Image] | None#
Gets the list of associated images.
- property ANSYSAnalysisSettings.IncludeNegativeLoadMultiplier: Ansys.Mechanical.DataModel.Enums.SolverControlsIncludeNegativeLoadMultiplier | None#
Gets or sets the IncludeNegativeLoadMultiplier.
- property ANSYSAnalysisSettings.IncludeResidualVector: bool | None#
Gets or sets the IncludeResidualVector.
- property ANSYSAnalysisSettings.InitialTimeStep: Ansys.Core.Units.Quantity | None#
Gets or sets the InitialTimeStep.
- property ANSYSAnalysisSettings.InternalObject: Ansys.Common.Interop.DSObjectsAuto.IDSAnalysisSettings | None#
Gets the internal object. For advanced usage only.
- property ANSYSAnalysisSettings.InverseOptionEndStep: int | None#
Gets or sets the InverseOptionEndStep.
- property ANSYSAnalysisSettings.KeepPreStressLoadPattern: bool | None#
Gets or sets the KeepPreStressLoadPattern.
- property ANSYSAnalysisSettings.KrylovResidualTolerance: float | None#
Gets or sets the KrylovResidualTolerance.
- property ANSYSAnalysisSettings.KrylovSubspaceDimension: int | None#
Gets or sets the KrylovSubspaceDimension.
- property ANSYSAnalysisSettings.KrylovSubspaceFrequency: Ansys.Core.Units.Quantity | None#
Gets or sets the KrylovSubspaceFrequency.
- property ANSYSAnalysisSettings.LimitSearchToRange: bool | None#
Gets or sets the LimitSearchToRange.
- property ANSYSAnalysisSettings.LineSearch: Ansys.Mechanical.DataModel.Enums.LineSearchType | None#
Gets or sets the LineSearch.
- property ANSYSAnalysisSettings.MaximumHarmonicIndex: int | None#
Gets or sets the MaximumHarmonicIndex.
- property ANSYSAnalysisSettings.MaximumPointsToSavePerStep: int | None#
Gets or sets the MaximumPointsToSavePerStep.
- property ANSYSAnalysisSettings.MaximumTimeStep: Ansys.Core.Units.Quantity | None#
Gets or sets the MaximumTimeStep.
- property ANSYSAnalysisSettings.MeshRetainFilesAfterFullSolve: Ansys.Mechanical.DataModel.Enums.MeshRestartRetainFilesType | None#
Gets or sets the MeshRetainFilesAfterFullSolve.
- property ANSYSAnalysisSettings.MeshSaveAtLoadStep: Ansys.Mechanical.DataModel.Enums.MeshRestartSaveAtLoadStep | None#
Gets or sets the MeshSaveAtLoadStep.
- property ANSYSAnalysisSettings.MeshSaveAtSubstep: Ansys.Mechanical.DataModel.Enums.MeshRestartSaveAtSubstep | None#
Gets or sets the MeshSaveAtSubstep.
- property ANSYSAnalysisSettings.MinimumElementSize: Ansys.Core.Units.Quantity | None#
Gets or sets the Minimum Element Size property for Geometry Based Adaptivity.
- property ANSYSAnalysisSettings.MinimumHarmonicIndex: int | None#
Gets or sets the MinimumHarmonicIndex.
- property ANSYSAnalysisSettings.MinimumTimeStep: Ansys.Core.Units.Quantity | None#
Gets or sets the MinimumTimeStep.
- property ANSYSAnalysisSettings.ModalFrequencyRange: Ansys.Mechanical.DataModel.Enums.ModalFrequencyRangeType | None#
Gets or sets the ModalFrequencyRange.
- property ANSYSAnalysisSettings.ModalNumberOfPoints: int | None#
Gets or sets the ModalNumberOfPoints.
- property ANSYSAnalysisSettings.ModalRangeMaximum: Ansys.Core.Units.Quantity | None#
Gets or sets the ModalRangeMaximum.
- property ANSYSAnalysisSettings.ModalRangeMinimum: Ansys.Core.Units.Quantity | None#
Gets or sets the ModalRangeMinimum.
- property ANSYSAnalysisSettings.ModeReuse: Ansys.Mechanical.DataModel.Enums.SolverControlsModeReuse | None#
Gets or sets the ModeReuse.
- property ANSYSAnalysisSettings.ModeSelectionMethod: Ansys.Mechanical.DataModel.Enums.ModeSelectionMethod | None#
Gets or sets the ModeSelectionMethod.
- property ANSYSAnalysisSettings.ModeSignificanceLevel: float | None#
Gets or sets the ModeSignificanceLevel.
- property ANSYSAnalysisSettings.ModesCombinationType: Ansys.Mechanical.DataModel.Enums.ModesCombinationType | None#
Gets or sets the ModesCombinationType.
- property ANSYSAnalysisSettings.MomentConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the MomentConvergence.
- property ANSYSAnalysisSettings.MomentConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the MomentConvergenceMinimumReference.
- property ANSYSAnalysisSettings.MomentConvergenceTolerance: Ansys.Core.Units.Quantity | None#
Gets or sets the MomentConvergenceTolerance.
- property ANSYSAnalysisSettings.MomentConvergenceValue: Ansys.Core.Units.Quantity | None#
Gets or sets the MomentConvergenceValue.
- property ANSYSAnalysisSettings.MultistepType: Ansys.Mechanical.DataModel.Enums.HarmonicMultiStepType | None#
Gets or sets the MultistepType.
- property ANSYSAnalysisSettings.NewtonRaphsonOption: Ansys.Mechanical.DataModel.Enums.NewtonRaphsonType | None#
Gets or sets the NewtonRaphsonOption.
- property ANSYSAnalysisSettings.NodalForces: Ansys.Mechanical.DataModel.Enums.OutputControlsNodalForcesType | None#
Gets or sets the NodalForces.
- property ANSYSAnalysisSettings.NonLinearFormulation: Ansys.Mechanical.DataModel.Enums.NonLinearFormulationType | None#
Gets or sets the NonLinearFormulation.
- property ANSYSAnalysisSettings.NumberOfSculptedLayersQualityImprovement: int | None#
Gets or sets the NumberOfSculptedLayersQualityImprovement.
- property ANSYSAnalysisSettings.NumberOfSculptedLayersRefinement: int | None#
Gets or sets the NumberOfSculptedLayersRefinement.
- property ANSYSAnalysisSettings.NumericalDamping: Ansys.Mechanical.DataModel.Enums.TransientDampingType | None#
Gets or sets the NumericalDamping.
- property ANSYSAnalysisSettings.NumericalDampingValue: float | None#
Gets or sets the NumericalDampingValue.
- property ANSYSAnalysisSettings.OnDemandExpansionOption: Ansys.Mechanical.DataModel.Enums.OnDemandExpansionType | None#
Gets or sets the OnDemandExpansionOption.
- property ANSYSAnalysisSettings.ParticipationFactor: Ansys.Mechanical.DataModel.Enums.CalculateParticipationFactorResult | None#
Gets or sets the ParticipationFactor.
- property ANSYSAnalysisSettings.ProjectToGeometry: Ansys.Mechanical.DataModel.Enums.NLADControlProjectToGeometry | None#
Gets or sets the ProjectToGeometry.
- property ANSYSAnalysisSettings.Properties: tuple[Ansys.ACT.Automation.Mechanical.Property] | None#
Gets the list of properties for this object.
- property ANSYSAnalysisSettings.QuasiStaticSolution: bool | None#
Gets or sets the QuasiStaticSolution.
- property ANSYSAnalysisSettings.RadiositySolver: Ansys.Mechanical.DataModel.Enums.RadiositySolverType | None#
Gets or sets the RadiositySolver.
- property ANSYSAnalysisSettings.RangeMaximum: Ansys.Core.Units.Quantity | None#
Gets or sets the Range Maximum property in Options group of Analysis Settings in Harmonic Analysis.
- property ANSYSAnalysisSettings.RangeMinimum: Ansys.Core.Units.Quantity | None#
Gets or sets the Range Minimum property in Options group of Analysis Settings in Harmonic Analysis.
- property ANSYSAnalysisSettings.ReferenceTemperature: Ansys.Core.Units.Quantity | None#
Gets or sets the AM Reference Temperature.
- property ANSYSAnalysisSettings.ReferenceTemperatureType: Ansys.Mechanical.DataModel.Enums.AMReferenceTemperatureType | None#
Gets or sets the AM Reference Temperature Type.
- property ANSYSAnalysisSettings.RefinementAlgorithm: Ansys.Mechanical.DataModel.Enums.NonlinearAdaptivityControlsRefinementAlgorithmType | None#
Gets or sets the RefinementAlgorithm.
- property ANSYSAnalysisSettings.ReformulationTolerance: float | None#
Gets or sets the ReformulationTolerance.
- property ANSYSAnalysisSettings.RelaxationTemperature: Ansys.Core.Units.Quantity | None#
Gets or sets the RelaxationTemperature.
- property ANSYSAnalysisSettings.RelaxationTemperatureType: Ansys.Mechanical.DataModel.Enums.AMRelaxationTemperatureType | None#
Gets or sets the AM Relaxation Temperature Type.
- property ANSYSAnalysisSettings.RemeshingGradient: Ansys.Mechanical.DataModel.Enums.NonlinearAdaptivityControlsRemeshingGradientType | None#
Gets or sets the RemeshingGradient.
- property ANSYSAnalysisSettings.RemeshingToleranceQualityImprovement: float | None#
Gets or sets the RemeshingToleranceQualityImprovement.
- property ANSYSAnalysisSettings.RemeshingToleranceRefinement: float | None#
Gets or sets the RemeshingToleranceRefinement.
- property ANSYSAnalysisSettings.RemovalDirection: Ansys.Core.Units.Quantity | None#
Gets or sets the RemovalDirection.
- property ANSYSAnalysisSettings.RemovalStepSize: Ansys.Core.Units.Quantity | None#
Gets or sets the RemovalStepSize.
- property ANSYSAnalysisSettings.RestartType: Ansys.Mechanical.DataModel.Enums.RestartType | None#
Gets or sets the RestartType.
- property ANSYSAnalysisSettings.ResultFileCompression: Ansys.Mechanical.DataModel.Enums.ResultFileCompressionType | None#
Gets or sets the ResultFileCompression.
- property ANSYSAnalysisSettings.RetainFilesAfterFullSolve: Ansys.Mechanical.DataModel.Enums.RestartRetainFilesType | None#
Gets or sets the RetainFilesAfterFullSolve.
- property ANSYSAnalysisSettings.RetainModesymFileAfterSolve: Ansys.Mechanical.DataModel.Enums.UseExistingModesymFile | None#
Gets or sets the RetainModesymFileAfterSolve.
- property ANSYSAnalysisSettings.RotationConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the RotationConvergence.
- property ANSYSAnalysisSettings.RotationConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the RotationConvergenceMinimumReference.
- property ANSYSAnalysisSettings.RotationConvergenceTolerance: Ansys.Core.Units.Quantity | None#
Gets or sets the RotationConvergenceTolerance.
- property ANSYSAnalysisSettings.RpmCentralFrequency: Ansys.Core.Units.Quantity | None#
Gets or sets the RpmCentralFrequency.
- property ANSYSAnalysisSettings.RpmFrequencySpacing: Ansys.Mechanical.DataModel.Enums.FrequencySpacingType | None#
Gets or sets the RpmFrequencySpacing.
- property ANSYSAnalysisSettings.RpmRangeMaximum: Ansys.Core.Units.Quantity | None#
Gets or sets the RpmRangeMaximum.
- property ANSYSAnalysisSettings.RpmRangeMinimum: Ansys.Core.Units.Quantity | None#
Gets or sets the RpmRangeMinimum.
- property ANSYSAnalysisSettings.RpmSolutionIntervals: int | None#
Gets or sets the RpmSolutionIntervals.
- property ANSYSAnalysisSettings.RpmValue: Ansys.Core.Units.Quantity | None#
Gets or sets the RpmValue.
- property ANSYSAnalysisSettings.SaveAtLoadStep: Ansys.Mechanical.DataModel.Enums.RestartSaveAtLoadStep | None#
Gets or sets the SaveAtLoadStep.
- property ANSYSAnalysisSettings.SaveAtSubstep: Ansys.Mechanical.DataModel.Enums.RestartSaveAtSubstep | None#
Gets or sets the SaveAtSubstep.
- property ANSYSAnalysisSettings.SaveSpecifiedLoadStep: int | None#
Gets or sets the SaveSpecifiedLoadStep.
- property ANSYSAnalysisSettings.ScatteredFieldFormulation: Ansys.Mechanical.DataModel.Enums.ScatteredFieldFormulation | None#
Gets or sets the ScatteredFieldFormulation.
- property ANSYSAnalysisSettings.ScatteringOutputType: Ansys.Mechanical.DataModel.Enums.ScatteringOutputType | None#
Gets or sets the ScatteringOutputType.
- property ANSYSAnalysisSettings.ScratchSolverFilesDirectory: str | None#
Gets the ScratchSolverFilesDirectory.
- property ANSYSAnalysisSettings.SearchRangeMaximum: Ansys.Core.Units.Quantity | None#
Gets or sets the Range Maximum property in Options group of Analysis Settings in Modal Analysis.
- property ANSYSAnalysisSettings.SearchRangeMinimum: Ansys.Core.Units.Quantity | None#
Gets or sets the Range Minimum property in Options group of Analysis Settings in Modal Analysis.
- property ANSYSAnalysisSettings.SignificanceThreshold: float | None#
Gets or sets the SignificanceThreshold.
- property ANSYSAnalysisSettings.SolutionMethod: Ansys.Mechanical.DataModel.Enums.HarmonicMethod | None#
Gets or sets the SolutionMethod.
- property ANSYSAnalysisSettings.SolverPivotChecking: Ansys.Mechanical.DataModel.Enums.SolverPivotChecking | None#
Gets or sets the SolverPivotChecking.
- property ANSYSAnalysisSettings.SolverTolerance: Ansys.Core.Units.Quantity | None#
Gets or sets the SolverTolerance.
- property ANSYSAnalysisSettings.SolverType: Ansys.Mechanical.DataModel.Enums.SolverType | None#
Gets or sets the SolverType.
- property ANSYSAnalysisSettings.SolverUnitSystem: Ansys.Mechanical.DataModel.Enums.WBUnitSystemType | None#
Gets or sets the SolverUnitSystem.
- property ANSYSAnalysisSettings.SolverUnits: Ansys.Mechanical.DataModel.Enums.SolverUnitsControlType | None#
Gets or sets the SolverUnits.
- property ANSYSAnalysisSettings.SpectrumType: Ansys.Mechanical.DataModel.Enums.SpectrumType | None#
Gets or sets the SpectrumType.
- property ANSYSAnalysisSettings.SpinSoftening: Ansys.Mechanical.DataModel.Enums.SpinSofteningType | None#
Gets or sets the SpinSoftening.
- property ANSYSAnalysisSettings.SpringStiffness: Ansys.Mechanical.DataModel.Enums.SpringsStiffnessType | None#
Gets or sets the SpringStiffness.
- property ANSYSAnalysisSettings.SpringStiffnessFactor: float | None#
Gets or sets the SpringStiffnessFactor.
- property ANSYSAnalysisSettings.SpringStiffnessValue: Ansys.Core.Units.Quantity | None#
Gets or sets the SpringStiffnessValue.
- property ANSYSAnalysisSettings.Stabilization: Ansys.Mechanical.DataModel.Enums.StabilizationType | None#
Gets or sets the Stabilization.
- property ANSYSAnalysisSettings.StabilizationActivationForFirstSubstep: Ansys.Mechanical.DataModel.Enums.StabilizationFirstSubstepOption | None#
Gets or sets the StabilizationActivationForFirstSubstep.
- property ANSYSAnalysisSettings.StabilizationDampingFactor: float | None#
Gets or sets the StabilizationDampingFactor.
- property ANSYSAnalysisSettings.StabilizationEnergyDissipationRatio: float | None#
Gets or sets the StabilizationEnergyDissipationRatio.
- property ANSYSAnalysisSettings.StabilizationForceLimit: float | None#
Gets or sets the StabilizationForceLimit.
- property ANSYSAnalysisSettings.StabilizationMethod: Ansys.Mechanical.DataModel.Enums.StabilizationMethod | None#
Gets or sets the StabilizationMethod.
- property ANSYSAnalysisSettings.StepEndTime: Ansys.Core.Units.Quantity | None#
Gets or sets the StepEndTime.
- property ANSYSAnalysisSettings.StiffnessCoefficient: float | None#
Gets or sets the StiffnessCoefficient.
- property ANSYSAnalysisSettings.StiffnessCoefficientDefineBy: Ansys.Mechanical.DataModel.Enums.DampingType | None#
Gets or sets the StiffnessCoefficientDefineBy.
- property ANSYSAnalysisSettings.StoreComplexSolution: bool | None#
Gets or sets the StoreComplexSolution.
- property ANSYSAnalysisSettings.StoreModalResults: Ansys.Mechanical.DataModel.Enums.StoreModalResult | None#
Gets or sets the StoreModalResults.
- property ANSYSAnalysisSettings.StoreResultsAt: Ansys.Mechanical.DataModel.Enums.TimePointsOptions | None#
Gets or sets the StoreResultsAt.
- property ANSYSAnalysisSettings.StoreResultsAtAllFrequencies: Ansys.Mechanical.DataModel.Enums.HarmonicMSUPStorage | None#
Gets or sets the StoreResultsAtAllFrequencies.
- property ANSYSAnalysisSettings.StructuralDampingCoefficient: float | None#
Gets or sets the StructuralDampingCoefficient.
- property ANSYSAnalysisSettings.TemperatureConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the TemperatureConvergence.
- property ANSYSAnalysisSettings.TemperatureConvergenceInputValue: Ansys.Core.Units.Quantity | None#
Gets or sets the TemperatureConvergenceInputValue.
- property ANSYSAnalysisSettings.TemperatureConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the TemperatureConvergenceMinimumReference.
- property ANSYSAnalysisSettings.TemperatureConvergenceTolerance: float | None#
Gets or sets the TemperatureConvergenceTolerance.
- property ANSYSAnalysisSettings.TemperatureConvergenceValue: Ansys.Mechanical.DataModel.Enums.NonLinearValueType | None#
Gets or sets the TemperatureConvergenceValue.
- property ANSYSAnalysisSettings.TimeStep: Ansys.Core.Units.Quantity | None#
Gets or sets the TimeStep.
- property ANSYSAnalysisSettings.TransientApplication: Ansys.Mechanical.DataModel.Enums.TransientApplicationType | None#
Gets or sets the TransientApplication.
- property ANSYSAnalysisSettings.TransientApplicationUserDefined: float | None#
Gets or sets the TransientApplicationUserDefined.
- property ANSYSAnalysisSettings.UserDefinedFrequencies: bool | None#
Gets or sets the UserDefinedFrequencies.
- property ANSYSAnalysisSettings.UserDefinedFrequencySteps: List[Ansys.Core.Units.Quantity] | None#
Gets or sets the UserDefinedFrequencySteps.
- property ANSYSAnalysisSettings.ViewFactorMethod: Ansys.Mechanical.DataModel.Enums.RadiosityViewFactorType | None#
Gets or sets the ViewFactorMethod.
- property ANSYSAnalysisSettings.VisibleProperties: tuple[Ansys.ACT.Automation.Mechanical.Property] | None#
Gets the list of properties that are visible for this object.
- property ANSYSAnalysisSettings.VoltageConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the VoltageConvergence.
- property ANSYSAnalysisSettings.VoltageConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the VoltageConvergenceMinimumReference.
- property ANSYSAnalysisSettings.VoltageConvergenceTolerance: float | None#
Gets or sets the VoltageConvergenceTolerance.
- property ANSYSAnalysisSettings.VoltageConvergenceValue: Ansys.Core.Units.Quantity | None#
Gets or sets the VoltageConvergenceValue.
- property ANSYSAnalysisSettings.WeakSprings: Ansys.Mechanical.DataModel.Enums.WeakSpringsType | None#
Gets or sets the WeakSprings.
Method detail#
- ANSYSAnalysisSettings.AddComment() Ansys.ACT.Automation.Mechanical.Comment #
Creates a new child Comment.
- ANSYSAnalysisSettings.AddFigure() Ansys.ACT.Automation.Mechanical.Figure #
Creates a new child Figure.
- ANSYSAnalysisSettings.AddImage(filePath: str) Ansys.ACT.Automation.Mechanical.Image #
Creates a new child Image.
If a filePath is provided, the image will be loaded from that file,
if not, the image will be a screen capture of the Geometry window.
- ANSYSAnalysisSettings.CopyTo(other: Ansys.ACT.Automation.Mechanical.DataModelObject) None #
CopyTo method.
- ANSYSAnalysisSettings.CreateParameter(propName: str) Ansys.ACT.Interfaces.Mechanical.IParameter #
Creates a new parameter for a Property.
- ANSYSAnalysisSettings.Duplicate() Ansys.Mechanical.DataModel.Interfaces.IDataModelObject #
Creates a copy of the current DataModelObject.
- ANSYSAnalysisSettings.GetAMStepType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.AMProcessStepType #
Gets the AM Process Step Type at a given step.
- ANSYSAnalysisSettings.GetAutomaticTimeStepping(stepNumber: int) Ansys.Mechanical.DataModel.Enums.AutomaticTimeStepping #
Gets the Automatic Time Stepping at a given solution step.
- ANSYSAnalysisSettings.GetCarryOverTimeStep(stepNumber: int) bool #
Gets the Carry Over Time Step at a given solution step.
- ANSYSAnalysisSettings.GetChildren(recurses: bool, children: List[ChildrenType]) List[ChildrenType] #
Gets the list of children, filtered by type.
- ANSYSAnalysisSettings.GetCreepEffects(stepNumber: int) Ansys.Mechanical.DataModel.Enums.Creep #
Gets the Creep Effects for a given solution step.
- ANSYSAnalysisSettings.GetCreepLimitRatio(stepNumber: int) float #
Gets the Creep Limit Ratio for a given solution step.
- ANSYSAnalysisSettings.GetCurrentConvergenceMinimumReference(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Current Convergence Minimum Reference at a given solution step.
- ANSYSAnalysisSettings.GetCurrentConvergenceTolerance(stepNumber: int) float #
Gets the Current Convergence Tolerance as a percentage at a given solution step.
- ANSYSAnalysisSettings.GetCurrentConvergenceType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType #
Gets the Current Convergence Tolerance type at a given solution step.
- ANSYSAnalysisSettings.GetCurrentConvergenceValue(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Current Convergence Value at a given solution step.
- ANSYSAnalysisSettings.GetDefineBy(stepNumber: int) Ansys.Mechanical.DataModel.Enums.TimeStepDefineByType #
Gets the Define By at a given solution step.
- ANSYSAnalysisSettings.GetDisplacementConvergenceMinimumReference(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Displacement Convergence Minimum Reference at a given solution step.
- ANSYSAnalysisSettings.GetDisplacementConvergenceTolerance(stepNumber: int) float #
Gets the Displacement Convergence Tolerance as a percentage at a given solution step.
- ANSYSAnalysisSettings.GetDisplacementConvergenceType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType #
Gets the Displacement Convergence Tolerance type at a given solution step.
- ANSYSAnalysisSettings.GetDisplacementConvergenceValue(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Displacement Convergence Value at a given solution step.
- ANSYSAnalysisSettings.GetEmagAMPSConvergenceMinimumReference(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the EmagAMPS Convergence Minimum Reference at a given solution step.
- ANSYSAnalysisSettings.GetEmagAMPSConvergenceTolerance(stepNumber: int) float #
Gets the EmagAMPS Convergence Tolerance as a percentage at a given solution step.
- ANSYSAnalysisSettings.GetEmagAMPSConvergenceType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType #
Gets the EmagAMPS Convergence Tolerance type at a given solution step.
- ANSYSAnalysisSettings.GetEmagAMPSConvergenceValue(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the EmagAMPS Convergence Value at a given solution step.
- ANSYSAnalysisSettings.GetEmagCSGConvergenceMinimumReference(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the EmagCSG Convergence Minimum Reference at a given solution step.
- ANSYSAnalysisSettings.GetEmagCSGConvergenceTolerance(stepNumber: int) float #
Gets the EmagCSG Convergence Tolerance as a percentage at a given solution step.
- ANSYSAnalysisSettings.GetEmagCSGConvergenceType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType #
Gets the EmagCSG Convergence Tolerance type at a given solution step.
- ANSYSAnalysisSettings.GetEmagCSGConvergenceValue(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the EmagCSG Convergence Value at a given solution step.
- ANSYSAnalysisSettings.GetEnergyConvergenceMinimumReference(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Energy Convergence Minimum Reference at a given solution step.
- ANSYSAnalysisSettings.GetEnergyConvergenceTolerance(stepNumber: int) float #
Gets the Energy Convergence Tolerance as a percentage at a given solution step.
- ANSYSAnalysisSettings.GetEnergyConvergenceType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType #
Gets the Energy Convergence Tolerance type at a given solution step.
- ANSYSAnalysisSettings.GetEnergyConvergenceValue(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Energy Convergence Value at a given solution step.
- ANSYSAnalysisSettings.GetForceConvergenceMinimumReference(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Force Convergence Minimum Reference at a given solution step.
- ANSYSAnalysisSettings.GetForceConvergenceTolerance(stepNumber: int) float #
Gets the Force Convergence Tolerance as a percentage at a given solution step.
- ANSYSAnalysisSettings.GetForceConvergenceType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType #
Gets the Force Convergence Tolerance Type at a given solution step.
- ANSYSAnalysisSettings.GetForceConvergenceValue(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Force Convergence Value at a given solution step.
- ANSYSAnalysisSettings.GetHeatConvergenceMinimumReference(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Heat Convergence Minimum Reference at a given solution step.
- ANSYSAnalysisSettings.GetHeatConvergenceTolerance(stepNumber: int) float #
Gets the Heat Convergence Tolerance as a percentage at a given solution step.
- ANSYSAnalysisSettings.GetHeatConvergenceType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType #
Gets the Heat Convergence Tolerance type at a given solution step.
- ANSYSAnalysisSettings.GetHeatConvergenceValue(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Heat Convergence Value at a given solution step.
- ANSYSAnalysisSettings.GetInitialSubsteps(stepNumber: int) int #
Gets the Initial Substeps at a given solution step.
- ANSYSAnalysisSettings.GetInitialTimeStep(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Initial Time Step at a given solution step.
- ANSYSAnalysisSettings.GetLineSearch(stepNumber: int) Ansys.Mechanical.DataModel.Enums.LineSearchType #
Gets the Line Search at a given solution step.
- ANSYSAnalysisSettings.GetMaximumSubsteps(stepNumber: int) int #
Gets the Maximum Substeps at a given solution step.
- ANSYSAnalysisSettings.GetMaximumTimeStep(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Maximum Time Step at a given solution step.
- ANSYSAnalysisSettings.GetMinimumSubsteps(stepNumber: int) int #
Gets the Minimum Substeps at a given solution step.
- ANSYSAnalysisSettings.GetMinimumTimeStep(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Minimum Time Step at a given solution step.
- ANSYSAnalysisSettings.GetMomentConvergenceMinimumReference(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Moment Convergence Minimum Reference at a given solution step.
- ANSYSAnalysisSettings.GetMomentConvergenceTolerance(stepNumber: int) float #
Gets the Moment Convergence Tolerance as a percentage at a given solution step.
- ANSYSAnalysisSettings.GetMomentConvergenceType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType #
Gets the Moment Convergence Tolerance type at a given solution step.
- ANSYSAnalysisSettings.GetMomentConvergenceValue(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Moment Convergence Value at a given solution step.
- ANSYSAnalysisSettings.GetNumberOfSubSteps(stepNumber: int) int #
Gets the Number of Substeps for a given solution step.
- ANSYSAnalysisSettings.GetParameter(propName: str) Ansys.ACT.Interfaces.Mechanical.IParameter #
Gets the parameter corresponding to the given property.
- ANSYSAnalysisSettings.GetRotationConvergenceMinimumReference(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Rotation Convergence Minimum Reference at a given solution step.
- ANSYSAnalysisSettings.GetRotationConvergenceTolerance(stepNumber: int) float #
Gets the Rotation Convergence Tolerance as a percentage at a given solution step.
- ANSYSAnalysisSettings.GetRotationConvergenceType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType #
Gets the Rotation Convergence Tolerance type at a given solution step.
- ANSYSAnalysisSettings.GetRotationConvergenceValue(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Rotation Convergence Value at a given solution step.
- ANSYSAnalysisSettings.GetStabilization(stepNumber: int) Ansys.Mechanical.DataModel.Enums.StabilizationType #
Gets the Stabilization at a given solution step.
- ANSYSAnalysisSettings.GetStabilizationDampingFactor(stepNumber: int) float #
Gets the Stabilization Damping Factor at a given solution step.
- ANSYSAnalysisSettings.GetStabilizationEnergyDissipationRatio(stepNumber: int) float #
Gets the Stabilization Energy Dissipation Ratio at a given solution step.
- ANSYSAnalysisSettings.GetStabilizationFirstSubstepOption(stepNumber: int) Ansys.Mechanical.DataModel.Enums.StabilizationFirstSubstepOption #
Gets the Stabilization First Substep Option at a given solution step.
- ANSYSAnalysisSettings.GetStabilizationForceLimit(stepNumber: int) float #
Gets the Stabilization Force Limit at a given solution step.
- ANSYSAnalysisSettings.GetStabilizationMethod(stepNumber: int) Ansys.Mechanical.DataModel.Enums.StabilizationMethod #
Gets the Stabilization Method at a given solution step.
- ANSYSAnalysisSettings.GetStepEndTime(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Step End Time at a given solution step.
- ANSYSAnalysisSettings.GetStoreResulsAtValue(stepNumber: int) int #
Gets the Store Results At Value at a given solution step.
- ANSYSAnalysisSettings.GetStoreResultsAt(stepNumber: int) Ansys.Mechanical.DataModel.Enums.TimePointsOptions #
Gets the Store Results At at a given solution step.
- ANSYSAnalysisSettings.GetStructuralOnly(stepNumber: int) bool #
Gets the TimeIntegration Structural for a given solution step.
- ANSYSAnalysisSettings.GetTemperatureConvergenceInputValue(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Temperature Convergence Input Value at a given solution step.
- ANSYSAnalysisSettings.GetTemperatureConvergenceMinimumReference(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Temperature Convergence Minimum Reference at a given solution step.
- ANSYSAnalysisSettings.GetTemperatureConvergenceTolerance(stepNumber: int) float #
Gets the Temperature Convergence Tolerance as a percentage at a given solution step.
- ANSYSAnalysisSettings.GetTemperatureConvergenceType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType #
Gets the Temperature Convergence Tolerance type at a given solution step.
- ANSYSAnalysisSettings.GetTemperatureConvergenceValue(stepNumber: int) Ansys.Mechanical.DataModel.Enums.NonLinearValueType #
Gets the Temperature Convergence Value at a given solution step.
- ANSYSAnalysisSettings.GetThermalOnly(stepNumber: int) bool #
Sets the TimeIntegration Thermal for a given solution step.
- ANSYSAnalysisSettings.GetTimeIntegration(stepNumber: int) bool #
Gets the TimeIntegration for a given solution step.
- ANSYSAnalysisSettings.GetTimeStep(stepNumber: int) Ansys.Core.Units.Quantity #
Sets the Time Step for a given solution step.
- ANSYSAnalysisSettings.GetVoltageConvergenceMinimumReference(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Voltage Convergence Minimum Reference at a given solution step.
- ANSYSAnalysisSettings.GetVoltageConvergenceTolerance(stepNumber: int) float #
Gets the Voltage Convergence Tolerance as a percentage at a given solution step.
- ANSYSAnalysisSettings.GetVoltageConvergenceType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType #
Gets the Voltage Convergence Tolerance type at a given solution step.
- ANSYSAnalysisSettings.GetVoltageConvergenceValue(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Voltage Convergence Value at a given solution step.
- ANSYSAnalysisSettings.GroupSimilarObjects() Ansys.ACT.Automation.Mechanical.TreeGroupingFolder #
Run the GroupSimilarObjects action.
Get a property by its API name.
If multiple properties have the same API Name, only the first property with that name will be returned.
- ANSYSAnalysisSettings.PropertyByName(name: str) Ansys.ACT.Automation.Mechanical.Property #
Get a property by its unique name.
- ANSYSAnalysisSettings.RemoveParameter(propName: str) None #
Removes the parameter from the parameter set corresponding to the given property.
- ANSYSAnalysisSettings.SetAutomaticTimeStepping(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.AutomaticTimeStepping) None #
Sets the Automatic Time Stepping for a given solution step.
- ANSYSAnalysisSettings.SetCarryOverTimeStep(stepNumber: int, value: bool) None #
Sets the Carry Over Time Step for a given solution step.
- ANSYSAnalysisSettings.SetChargeConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Charge Convergence Minimum Reference for a given solution step.
Sets the Charge Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetChargeConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the Charge Convergence Tolerance type for a given solution step.
- ANSYSAnalysisSettings.SetChargeConvergenceValue(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Charge Convergence Value for a given solution step.
- ANSYSAnalysisSettings.SetCreepEffects(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.Creep) None #
Sets the Creep Effects for a given solution step.
- ANSYSAnalysisSettings.SetCreepLimitRatio(stepNumber: int, value: float) None #
Sets the Creep Limit Ratio for a given solution step.
- ANSYSAnalysisSettings.SetCurrentConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Current Convergence Minimum Reference for a given solution step.
Sets the Current Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetCurrentConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the Current Convergence Tolerance type for a given solution step.
- ANSYSAnalysisSettings.SetCurrentConvergenceValue(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Current Convergence Value for a given solution step.
- ANSYSAnalysisSettings.SetDefineBy(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.TimeStepDefineByType) None #
Sets the Define By for a given solution step.
- ANSYSAnalysisSettings.SetDisplacementConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Displacement Convergence Minimum Reference for a given solution step.
Sets the Displacement Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetDisplacementConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the Displacement Convergence Tolerance type for a given solution step.
- ANSYSAnalysisSettings.SetDisplacementConvergenceValue(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Displacement Convergence Value for a given solution step.
- ANSYSAnalysisSettings.SetEmagAMPSConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the EmagAMPS Convergence Minimum Reference for a given solution step.
Sets the EmagAMPS Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetEmagAMPSConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the EmagAMPS Convergence Tolerance type for a given solution step.
- ANSYSAnalysisSettings.SetEmagAMPSConvergenceValue(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the EmagAMPS Convergence Value for a given solution step.
- ANSYSAnalysisSettings.SetEmagCSGConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the EmagCSG Convergence Minimum Reference for a given solution step.
Sets the EmagCSG Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetEmagCSGConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the EmagCSG Convergence Tolerance type for a given solution step.
- ANSYSAnalysisSettings.SetEmagCSGConvergenceValue(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the EmagCSG Convergence Value for a given solution step.
- ANSYSAnalysisSettings.SetEnergyConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Energy Convergence Minimum Reference for a given solution step.
Sets the Energy Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetEnergyConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the Energy Convergence Tolerance type for a given solution step.
- ANSYSAnalysisSettings.SetEnergyConvergenceValue(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Energy Convergence Value for a given solution step.
- ANSYSAnalysisSettings.SetForceConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Force Convergence Minimum Reference for a given solution step.
Sets the Force Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetForceConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the Force Convergence Tolerance Type for a given solution step.
- ANSYSAnalysisSettings.SetForceConvergenceValue(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Force Convergence Value for a given solution step.
- ANSYSAnalysisSettings.SetHeatConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Heat Convergence Minimum Reference for a given solution step.
Sets the Heat Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetHeatConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the Heat Convergence Tolerance type for a given solution step.
- ANSYSAnalysisSettings.SetHeatConvergenceValue(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Heat Convergence Value for a given solution step.
- ANSYSAnalysisSettings.SetInitialSubsteps(stepNumber: int, value: int) None #
Sets the Initial Substeps for a given solution step.
- ANSYSAnalysisSettings.SetInitialTimeStep(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Initial Time Step for a given solution step.
- ANSYSAnalysisSettings.SetLineSearch(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.LineSearchType) None #
Sets the Line Search for a given solution step.
- ANSYSAnalysisSettings.SetMaximumSubsteps(stepNumber: int, value: int) None #
Sets the Maximum Substeps for a given solution step.
- ANSYSAnalysisSettings.SetMaximumTimeStep(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Maximum Time Step for a given solution step.
- ANSYSAnalysisSettings.SetMinimumSubsteps(stepNumber: int, value: int) None #
Sets the Minimum Substeps for a given solution step.
- ANSYSAnalysisSettings.SetMinimumTimeStep(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Minimum Time Step for a given solution step.
- ANSYSAnalysisSettings.SetMomentConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Moment Convergence Minimum Reference for a given solution step.
Sets the Moment Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetMomentConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the Moment Convergence Tolerance type for a given solution step.
- ANSYSAnalysisSettings.SetMomentConvergenceValue(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Moment Convergence Value for a given solution step.
- ANSYSAnalysisSettings.SetNumberOfSubSteps(stepNumber: int, value: int) None #
Sets the Number of Substeps for a given solution step.
- ANSYSAnalysisSettings.SetRotationConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Rotation Convergence Minimum Reference for a given solution step.
Sets the Rotation Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetRotationConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the Rotation Convergence Tolerance type for a given solution step.
- ANSYSAnalysisSettings.SetRotationConvergenceValue(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Rotation Convergence Value for a given solution step.
- ANSYSAnalysisSettings.SetStabilization(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.StabilizationType) None #
Sets the Stabilization for a given solution step.
- ANSYSAnalysisSettings.SetStabilizationDampingFactor(stepNumber: int, value: float) None #
Sets the Stabilization Damping Factor for a given solution step.
- ANSYSAnalysisSettings.SetStabilizationEnergyDissipationRatio(stepNumber: int, value: float) None #
Sets the Stabilization Energy Dissipation Ratio for a given solution step.
- ANSYSAnalysisSettings.SetStabilizationFirstSubstepOption(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.StabilizationFirstSubstepOption) None #
Sets the Stabilization First Substep Option for a given solution step.
- ANSYSAnalysisSettings.SetStabilizationForceLimit(stepNumber: int, value: float) None #
Sets the Stabilization Force Limit for a given solution step.
- ANSYSAnalysisSettings.SetStabilizationMethod(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.StabilizationMethod) None #
Sets the Stabilization Method for a given solution step.
- ANSYSAnalysisSettings.SetStepEndTime(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Step End Time for a given solution step.
- ANSYSAnalysisSettings.SetStepName(stepNumber: int, value: str) None #
Sets the Step name at a given step.
- ANSYSAnalysisSettings.SetStoreResulsAtValue(stepNumber: int, value: int) None #
Sets the Store Results At Value for a given solution step.
- ANSYSAnalysisSettings.SetStoreResultsAt(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.TimePointsOptions) None #
Sets the Store Results At for a given solution step.
- ANSYSAnalysisSettings.SetStructuralOnly(stepNumber: int, value: bool) None #
Sets the TimeIntegration Structural for a given solution step.
- ANSYSAnalysisSettings.SetTemperatureConvergenceInputValue(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Temperature Convergence Input Value for a given solution step.
- ANSYSAnalysisSettings.SetTemperatureConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Temperature Convergence Minimum Reference for a given solution step.
Sets the Temperature Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetTemperatureConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the Temperature Convergence Tolerance type for a given solution step.
- ANSYSAnalysisSettings.SetTemperatureConvergenceValue(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.NonLinearValueType) None #
Sets the Temperature Convergence Value for a given solution step.
- ANSYSAnalysisSettings.SetThermalOnly(stepNumber: int, value: bool) None #
Sets the TimeIntegration Thermal for a given solution step.
- ANSYSAnalysisSettings.SetTimeIntegration(stepNumber: int, value: bool) None #
Sets the TimeIntegration for a given solution step.
- ANSYSAnalysisSettings.SetTimeStep(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Time Step for a given solution step.
- ANSYSAnalysisSettings.SetVoltageConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Voltage Convergence Minimum Reference for a given solution step.
Sets the Voltage Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetVoltageConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the Voltage Convergence Tolerance type for a given solution step.