ANSYSAnalysisSettings
#
- class ansys.mechanical.stubs.v251.Ansys.ACT.Automation.Mechanical.AnalysisSettings.ANSYSAnalysisSettings#
Bases:
object
Defines a ANSYSAnalysisSettings.
Overview#
Activate the current object. |
|
Creates a new child Comment. |
|
Creates a new child Figure. |
|
Creates a new child Image. |
|
CopyTo method. |
|
Creates a new parameter for a Property. |
|
DeleteAllRestartPoints method. |
|
Creates a copy of the current DataModelObject. |
|
Gets the AM Process Step Type at a given step. |
|
Gets the Automatic Time Stepping at a given solution step. |
|
Gets the Carry Over Time Step at a given solution step. |
|
Gets the list of children, filtered by type. |
|
Gets the Creep Effects for a given solution step. |
|
Gets the Creep Limit Ratio for a given solution step. |
|
Gets the Current Convergence Minimum Reference at a given solution step. |
|
Gets the Current Convergence Tolerance as a percentage at a given solution step. |
|
Gets the Current Convergence Tolerance type at a given solution step. |
|
Gets the Current Convergence Value at a given solution step. |
|
Gets the Define By at a given solution step. |
|
Gets the Displacement Convergence Minimum Reference at a given solution step. |
|
Gets the Displacement Convergence Tolerance as a percentage at a given solution step. |
|
Gets the Displacement Convergence Tolerance type at a given solution step. |
|
Gets the Displacement Convergence Value at a given solution step. |
|
Gets the EmagAMPS Convergence Minimum Reference at a given solution step. |
|
Gets the EmagAMPS Convergence Tolerance as a percentage at a given solution step. |
|
Gets the EmagAMPS Convergence Tolerance type at a given solution step. |
|
Gets the EmagAMPS Convergence Value at a given solution step. |
|
Gets the EmagCSG Convergence Minimum Reference at a given solution step. |
|
Gets the EmagCSG Convergence Tolerance as a percentage at a given solution step. |
|
Gets the EmagCSG Convergence Tolerance type at a given solution step. |
|
Gets the EmagCSG Convergence Value at a given solution step. |
|
Gets the Energy Convergence Minimum Reference at a given solution step. |
|
Gets the Energy Convergence Tolerance as a percentage at a given solution step. |
|
Gets the Energy Convergence Tolerance type at a given solution step. |
|
Gets the Energy Convergence Value at a given solution step. |
|
Gets the Force Convergence Minimum Reference at a given solution step. |
|
Gets the Force Convergence Tolerance as a percentage at a given solution step. |
|
Gets the Force Convergence Tolerance Type at a given solution step. |
|
Gets the Force Convergence Value at a given solution step. |
|
Gets the Heat Convergence Minimum Reference at a given solution step. |
|
Gets the Heat Convergence Tolerance as a percentage at a given solution step. |
|
Gets the Heat Convergence Tolerance type at a given solution step. |
|
Gets the Heat Convergence Value at a given solution step. |
|
Gets the Initial Substeps at a given solution step. |
|
Gets the Initial Time Step at a given solution step. |
|
Gets the Line Search at a given solution step. |
|
Gets the Maximum Substeps at a given solution step. |
|
Gets the Maximum Time Step at a given solution step. |
|
Gets the Minimum Substeps at a given solution step. |
|
Gets the Minimum Time Step at a given solution step. |
|
Gets the Moment Convergence Minimum Reference at a given solution step. |
|
Gets the Moment Convergence Tolerance as a percentage at a given solution step. |
|
Gets the Moment Convergence Tolerance type at a given solution step. |
|
Gets the Moment Convergence Value at a given solution step. |
|
Gets the Number of Substeps for a given solution step. |
|
Gets the parameter corresponding to the given property. |
|
Gets the Rotation Convergence Minimum Reference at a given solution step. |
|
Gets the Rotation Convergence Tolerance as a percentage at a given solution step. |
|
Gets the Rotation Convergence Tolerance type at a given solution step. |
|
Gets the Rotation Convergence Value at a given solution step. |
|
Gets the Stabilization at a given solution step. |
|
Gets the Stabilization Damping Factor at a given solution step. |
|
Gets the Stabilization Energy Dissipation Ratio at a given solution step. |
|
Gets the Stabilization First Substep Option at a given solution step. |
|
Gets the Stabilization Force Limit at a given solution step. |
|
Gets the Stabilization Method at a given solution step. |
|
Gets the Step End Time at a given solution step. |
|
Gets the Step name at a given step. |
|
Gets the Store Results At Value at a given solution step. |
|
Gets the Store Results At at a given solution step. |
|
Gets the TimeIntegration Structural for a given solution step. |
|
Gets the Temperature Convergence Input Value at a given solution step. |
|
Gets the Temperature Convergence Minimum Reference at a given solution step. |
|
Gets the Temperature Convergence Tolerance as a percentage at a given solution step. |
|
Gets the Temperature Convergence Tolerance type at a given solution step. |
|
Gets the Temperature Convergence Value at a given solution step. |
|
Sets the TimeIntegration Thermal for a given solution step. |
|
Gets the TimeIntegration for a given solution step. |
|
Sets the Time Step for a given solution step. |
|
Gets the Voltage Convergence Minimum Reference at a given solution step. |
|
Gets the Voltage Convergence Tolerance as a percentage at a given solution step. |
|
Gets the Voltage Convergence Tolerance type at a given solution step. |
|
Gets the Voltage Convergence Value at a given solution step. |
|
Run the GroupAllSimilarChildren action. |
|
Run the GroupSimilarObjects action. |
|
Get a property by its API name. |
|
Get a property by its unique name. |
|
Removes the parameter from the parameter set corresponding to the given property. |
|
Sets the Automatic Time Stepping for a given solution step. |
|
Sets the Carry Over Time Step for a given solution step. |
|
Sets the Charge Convergence Minimum Reference for a given solution step. |
|
Sets the Charge Convergence Tolerance as a percentage for a given solution step. |
|
Sets the Charge Convergence Tolerance type for a given solution step. |
|
Sets the Charge Convergence Value for a given solution step. |
|
Sets the Creep Effects for a given solution step. |
|
Sets the Creep Limit Ratio for a given solution step. |
|
Sets the Current Convergence Minimum Reference for a given solution step. |
|
Sets the Current Convergence Tolerance as a percentage for a given solution step. |
|
Sets the Current Convergence Tolerance type for a given solution step. |
|
Sets the Current Convergence Value for a given solution step. |
|
Sets the Define By for a given solution step. |
|
Sets the Displacement Convergence Minimum Reference for a given solution step. |
|
Sets the Displacement Convergence Tolerance as a percentage for a given solution step. |
|
Sets the Displacement Convergence Tolerance type for a given solution step. |
|
Sets the Displacement Convergence Value for a given solution step. |
|
Sets the EmagAMPS Convergence Minimum Reference for a given solution step. |
|
Sets the EmagAMPS Convergence Tolerance as a percentage for a given solution step. |
|
Sets the EmagAMPS Convergence Tolerance type for a given solution step. |
|
Sets the EmagAMPS Convergence Value for a given solution step. |
|
Sets the EmagCSG Convergence Minimum Reference for a given solution step. |
|
Sets the EmagCSG Convergence Tolerance as a percentage for a given solution step. |
|
Sets the EmagCSG Convergence Tolerance type for a given solution step. |
|
Sets the EmagCSG Convergence Value for a given solution step. |
|
Sets the Energy Convergence Minimum Reference for a given solution step. |
|
Sets the Energy Convergence Tolerance as a percentage for a given solution step. |
|
Sets the Energy Convergence Tolerance type for a given solution step. |
|
Sets the Energy Convergence Value for a given solution step. |
|
Sets the Force Convergence Minimum Reference for a given solution step. |
|
Sets the Force Convergence Tolerance as a percentage for a given solution step. |
|
Sets the Force Convergence Tolerance Type for a given solution step. |
|
Sets the Force Convergence Value for a given solution step. |
|
Sets the Heat Convergence Minimum Reference for a given solution step. |
|
Sets the Heat Convergence Tolerance as a percentage for a given solution step. |
|
Sets the Heat Convergence Tolerance type for a given solution step. |
|
Sets the Heat Convergence Value for a given solution step. |
|
Sets the Initial Substeps for a given solution step. |
|
Sets the Initial Time Step for a given solution step. |
|
Sets the Line Search for a given solution step. |
|
Sets the Maximum Substeps for a given solution step. |
|
Sets the Maximum Time Step for a given solution step. |
|
Sets the Minimum Substeps for a given solution step. |
|
Sets the Minimum Time Step for a given solution step. |
|
Sets the Moment Convergence Minimum Reference for a given solution step. |
|
Sets the Moment Convergence Tolerance as a percentage for a given solution step. |
|
Sets the Moment Convergence Tolerance type for a given solution step. |
|
Sets the Moment Convergence Value for a given solution step. |
|
Sets the Number of Substeps for a given solution step. |
|
Sets the Rotation Convergence Minimum Reference for a given solution step. |
|
Sets the Rotation Convergence Tolerance as a percentage for a given solution step. |
|
Sets the Rotation Convergence Tolerance type for a given solution step. |
|
Sets the Rotation Convergence Value for a given solution step. |
|
Sets the Stabilization for a given solution step. |
|
Sets the Stabilization Damping Factor for a given solution step. |
|
Sets the Stabilization Energy Dissipation Ratio for a given solution step. |
|
Sets the Stabilization First Substep Option for a given solution step. |
|
Sets the Stabilization Force Limit for a given solution step. |
|
Sets the Stabilization Method for a given solution step. |
|
Sets the Step End Time for a given solution step. |
|
Sets the Step name at a given step. |
|
Sets the Store Results At Value for a given solution step. |
|
Sets the Store Results At for a given solution step. |
|
Sets the TimeIntegration Structural for a given solution step. |
|
Sets the Temperature Convergence Input Value for a given solution step. |
|
Sets the Temperature Convergence Minimum Reference for a given solution step. |
|
Sets the Temperature Convergence Tolerance as a percentage for a given solution step. |
|
Sets the Temperature Convergence Tolerance type for a given solution step. |
|
Sets the Temperature Convergence Value for a given solution step. |
|
Sets the TimeIntegration Thermal for a given solution step. |
|
Sets the TimeIntegration for a given solution step. |
|
Sets the Time Step for a given solution step. |
|
Sets the Voltage Convergence Minimum Reference for a given solution step. |
|
Sets the Voltage Convergence Tolerance as a percentage for a given solution step. |
|
Sets the Voltage Convergence Tolerance type for a given solution step. |
|
Sets the Voltage Convergence Value for a given solution step. |
Gets or sets the AM Cooldown Number of Substeps. |
|
Gets or sets the AMPSConvergence. |
|
Gets or sets the AM Process Step Type. |
|
Gets or sets the AM Substeps Between Heating. |
|
Gets or sets the AM Substeps to Apply Heat. |
|
Gets or sets the AggressiveRemeshing. |
|
Gets or sets the AutomaticTimeStepping. |
|
Gets or sets the AxisymmetryDivisions. |
|
Gets or sets the BackStress. |
|
Gets or sets the BaseRemovalType. |
|
Gets or sets the BoundaryAngle. |
|
Gets or sets the CSGConvergence. |
|
Gets or sets the CStarIntegral. |
|
Gets or sets the CacheResultsInMemory. |
|
Gets or sets the CalculateAcceleration. |
|
Gets or sets the CalculateEnergy. |
|
Gets or sets the CalculateEulerAngles. |
|
Gets or sets the CalculateReactions. |
|
Gets or sets the CalculateThermalFlux. |
|
Gets or sets the CalculateVelocity. |
|
Gets or sets the CalculateVelocityAndAcceleration. |
|
Gets or sets the CalculateVolumeEnergy. |
|
Gets or sets the CampbellDiagram. |
|
Gets or sets the CarryOverTimeStep. |
|
Gets or sets the CentralFrequency. |
|
Gets or sets the ChargeConvergence. |
|
Gets or sets the ChargeConvergenceMinimumReference. |
|
Gets or sets the ChargeConvergenceTolerance. |
|
Gets or sets the ChargeConvergenceValue. |
|
Gets the list of children. |
|
Gets or sets the ClusterNumber. |
|
Gets or sets the ClusterResults. |
|
Gets or sets the CombineRestartFiles. |
|
Gets the list of associated comments. |
|
Gets or sets the ConstantDamping. |
|
Gets or sets the ConstantDampingRatio. |
|
Gets or sets the ContactData. |
|
Gets or sets the ContactMiscellaneous. |
|
Gets or sets the ContactSplit. |
|
Gets or sets the ContactSplitMaxNum. |
|
Gets or sets the ContactSummary. |
|
Gets or sets the AM Cooldown Time. |
|
Gets or sets the AM Cooldown Time Type. |
|
Gets or sets the CoriolisEffectApplied. |
|
Gets or sets the CreepEffects. |
|
Gets or sets the CreepLimitRatio. |
|
Gets or sets the CurrentConvergence. |
|
Gets or sets the CurrentConvergenceMinimumReference. |
|
Gets or sets the CurrentConvergenceTolerance. |
|
Gets or sets the CurrentConvergenceValue. |
|
Gets or sets the Current Restart Point. |
|
Gets or sets the CurrentStepNumber. |
|
Gets or sets the CurrentStepNumberHarmonic. |
|
Gets or sets the CyclicModeSuperposition. |
|
Gets or sets the Damped. |
|
Gets or sets the DampingDefineBy. |
|
Gets or sets the DampingRatio. |
|
Gets the current DataModelObject's category. |
|
Gets or sets the DefineBy. |
|
Gets or sets the DeleteUnneededFiles. |
|
Gets or sets the DisplacementConvergence. |
|
Gets or sets the DisplacementConvergenceMinimumReference. |
|
Gets or sets the DisplacementConvergenceTolerance. |
|
Gets or sets the DisplacementConvergenceValue. |
|
Gets or sets the EdgeSplittingAngle. |
|
Gets or sets the ElectricOnly. |
|
Gets or sets the ElectromagneticNodalForces. |
|
Gets or sets the ElementCurrentDensity. |
|
Gets or sets the EmagAMPSConvergenceMinimumReference. |
|
Gets or sets the EmagAMPSConvergenceTolerance. |
|
Gets or sets the EmagAMPSConvergenceValue. |
|
Gets or sets the EmagCSGConvergenceMinimumReference. |
|
Gets or sets the EmagCSGConvergenceTolerance. |
|
Gets or sets the EmagCSGConvergenceValue. |
|
Gets or sets the EnergyConvergence. |
|
Gets or sets the EnergyConvergenceMinimumReference. |
|
Gets or sets the EnergyConvergenceTolerance. |
|
Gets or sets the EnergyConvergenceValue. |
|
Gets or sets the EngineOrderofExcitation. |
|
Gets or sets the EqvDampingRatioFromModal. |
|
Gets or sets the ExcludeInsignificantModes. |
|
Gets or sets the ExpandResultsFrom. |
|
Gets the Expansion. |
|
Gets or sets the ExportHighStrains. |
|
Gets or sets the ExportLayerEndTemperature. |
|
Gets or sets the ExportRecoaterInterference. |
|
Gets or sets the FarFieldRadiationSurface. |
|
Gets or sets the FieldIntensityandFluxDensity. |
|
Gets the list of associated figures. |
|
Gets or sets the FluxConvergence. |
|
Gets or sets the ForceConvergence. |
|
Gets or sets the ForceConvergenceMinimumReference. |
|
Gets or sets the ForceConvergenceTolerance. |
|
Gets or sets the ForceConvergenceValue. |
|
Gets or sets the FractureSolverControls. |
|
Gets or sets the Frequency. |
|
Gets or sets the FrequencySpacing. |
|
Gets or sets the FutureAnalysis. |
|
Gets or sets the GeneralMiscellaneous. |
|
Gets or sets the GeneralMiscellaneousOption. |
|
Gets or sets the GenerateMeshRestartPoints. |
|
Gets or sets the GenerateRestartPoints. |
|
Gets or sets the GlobalSizeRatioQualityImprovement. |
|
Gets or sets the GlobalSizeRatioQualityRefinement. |
|
Graph property. |
|
Gets or sets the HarmonicIndexInterval. |
|
Gets or sets the HarmonicIndexRange. |
|
Gets or sets the HarmonicOrders. |
|
Gets or sets the HeatConvergence. |
|
Gets or sets the HeatConvergenceMinimumReference. |
|
Gets or sets the HeatConvergenceTolerance. |
|
Gets or sets the HeatConvergenceValue. |
|
Gets or sets the HeatGenerationRate. |
|
Gets or sets the HemicubeResolution. |
|
Gets or sets the IgnoreAcousticDamping. |
|
Gets the list of associated images. |
|
Gets or sets the IncludeNegativeLoadMultiplier. |
|
Gets or sets the IncludeResidualVector. |
|
Gets or sets the InertiaRelief. |
|
Gets or sets the InitialSubsteps. |
|
Gets or sets the InitialTimeStep. |
|
Gets the internal object. For advanced usage only. |
|
Gets or sets the InverseOption. |
|
Gets or sets the InverseOptionEndStep. |
|
Gets or sets the JIntegral. |
|
Gets or sets the KeepModalResults. |
|
Gets or sets the KeepPreStressLoadPattern. |
|
Gets or sets the KrylovResidualTolerance. |
|
Gets or sets the KrylovSubspaceDimension. |
|
Gets or sets the KrylovSubspaceFrequency. |
|
Gets or sets the LargeDeflection. |
|
Gets or sets the AM Layers to Build. |
|
Gets or sets the LimitSearchToRange. |
|
Gets or sets the LineSearch. |
|
Gets or sets the LoadStepValue. |
|
Gets or sets the MassCoefficient. |
|
Gets or sets the MaterialForce. |
|
Gets or sets the MaximumHarmonicIndex. |
|
Gets or sets the MaximumIteration. |
|
Gets or sets the MaximumModesToFind. |
|
Gets or sets the MaximumPointsToSavePerStep. |
|
Gets or sets the MaximumSubsteps. |
|
Gets or sets the MaximumTimeStep. |
|
Gets or sets the MeshLoadStepValue. |
|
Gets or sets the MeshRetainFilesAfterFullSolve. |
|
Gets or sets the MeshSaveAtLoadStep. |
|
Gets or sets the MeshSaveAtSubstep. |
|
Gets or sets the Minimum Element Size property for Geometry Based Adaptivity. |
|
Gets or sets the MinimumHarmonicIndex. |
|
Gets or sets the MinimumSubsteps. |
|
Gets or sets the MinimumTimeStep. |
|
Gets or sets the ModalFrequencyRange. |
|
Gets or sets the ModalNumberOfPoints. |
|
Gets or sets the ModalRangeMaximum. |
|
Gets or sets the ModalRangeMinimum. |
|
Gets or sets the ModeReuse. |
|
Gets or sets the ModeSelectionMethod. |
|
Gets or sets the ModeSignificanceLevel. |
|
Gets or sets the ModesCombinationType. |
|
Gets or sets the MomentConvergence. |
|
Gets or sets the MomentConvergenceMinimumReference. |
|
Gets or sets the MomentConvergenceTolerance. |
|
Gets or sets the MomentConvergenceValue. |
|
Gets or sets the Multistep. |
|
Gets or sets the MultistepType. |
|
Gets or sets the objects of type NamedSelection to – Named Selection property in the Output Controls group of Analysis Settings. |
|
Gets or sets the NewtonRaphsonOption. |
|
Gets or sets the NodalForces. |
|
Gets or sets the NonLinearFormulation. |
|
Gets the NonLinearSolution. |
|
Gets or sets the NonlinearData. |
|
Gets or sets the NumLoadVectors. |
|
Gets or sets the NumberOfModesToUse. |
|
Gets or sets the NumberOfRPMs. |
|
Gets Number of Restart Points. |
|
Gets or sets the NumberOfSculptedLayersQualityImprovement. |
|
Gets or sets the NumberOfSculptedLayersRefinement. |
|
Gets or sets the NumberOfSteps. |
|
Gets or sets the NumberOfSubSteps. |
|
Gets or sets the NumberOfZones. |
|
Gets or sets the NumericalDamping. |
|
Gets or sets the NumericalDampingValue. |
|
Gets or sets the OnDemandExpansionOption. |
|
Gets or sets the Output Selection property in the Output Controls group of Analysis Settings. |
|
Gets or sets the OverRelaxation. |
|
Gets or sets the ParticipationFactor. |
|
Gets or sets the ProjectToGeometry. |
|
Gets the list of properties for this object. |
|
Gets or sets the QuasiStaticSolution. |
|
Gets or sets the RadiositySolver. |
|
Gets or sets the Range Maximum property in Options group of Analysis Settings in Harmonic Analysis. |
|
Gets or sets the Range Minimum property in Options group of Analysis Settings in Harmonic Analysis. |
|
Gets or sets the AM Reference Temperature. |
|
Gets or sets the AM Reference Temperature Type. |
|
Gets or sets the RefinementAlgorithm. |
|
Gets or sets the ReformulationTolerance. |
|
Gets or sets the RelaxationTemperature. |
|
Gets or sets the AM Relaxation Temperature Type. |
|
Gets or sets the RemeshingGradient. |
|
Gets or sets the RemeshingToleranceQualityImprovement. |
|
Gets or sets the RemeshingToleranceRefinement. |
|
Gets or sets the RemovalDirection. |
|
Gets or sets the RemovalStepSize. |
|
Gets the RestartAtLoadStep. |
|
Gets the RestartAtSubstep. |
|
Gets the RestartAtTime. |
|
Gets or sets the RestartType. |
|
Gets or sets the ResultFileCompression. |
|
Gets or sets the RetainFilesAfterFullSolve. |
|
Gets or sets the RetainModesymFileAfterSolve. |
|
Gets or sets the RotationConvergence. |
|
Gets or sets the RotationConvergenceMinimumReference. |
|
Gets or sets the RotationConvergenceTolerance. |
|
Gets or sets the RpmCentralFrequency. |
|
Gets or sets the RpmClusterNumber. |
|
Gets or sets the RpmFrequencySpacing. |
|
Gets or sets the RpmRangeMaximum. |
|
Gets or sets the RpmRangeMinimum. |
|
Gets or sets the RpmSolutionIntervals. |
|
Gets or sets the RpmValue. |
|
Gets or sets the SIFS. |
|
Gets or sets the SaveAtLoadStep. |
|
Gets or sets the SaveAtSubstep. |
|
Gets or sets the SaveMAPDLDB. |
|
Gets or sets the SaveSpecifiedLoadStep. |
|
Gets or sets the ScatteredFieldFormulation. |
|
Gets or sets the ScatteringOutputType. |
|
Gets the ScratchSolverFilesDirectory. |
|
Gets or sets the Range Maximum property in Options group of Analysis Settings in Modal Analysis. |
|
Gets or sets the Range Minimum property in Options group of Analysis Settings in Modal Analysis. |
|
Gets or sets the SignificanceThreshold. |
|
Gets or sets the SolutionIntervals. |
|
Gets or sets the SolutionMethod. |
|
Gets the SolverFilesDirectory. |
|
Gets or sets the SolverPivotChecking. |
|
Gets or sets the SolverTolerance. |
|
Gets or sets the SolverType. |
|
Gets or sets the SolverUnitSystem. |
|
Gets or sets the SolverUnits. |
|
Gets or sets the SpectrumType. |
|
Gets or sets the SpinSoftening. |
|
Gets or sets the SpringStiffness. |
|
Gets or sets the SpringStiffnessFactor. |
|
Gets or sets the SpringStiffnessValue. |
|
Gets or sets the Stabilization. |
|
Gets or sets the StabilizationActivationForFirstSubstep. |
|
Gets or sets the StabilizationDampingFactor. |
|
Gets or sets the StabilizationEnergyDissipationRatio. |
|
Gets or sets the StabilizationForceLimit. |
|
Gets or sets the StabilizationMethod. |
|
Gets or sets the StepEndTime. |
|
Gets or sets the Step Name. |
|
Gets or sets the StiffnessCoefficient. |
|
Gets or sets the StiffnessCoefficientDefineBy. |
|
Gets or sets the StoreComplexSolution. |
|
Gets or sets the StoreModalResults. |
|
Gets or sets the StoreResulsAtValue. |
|
Gets or sets the StoreResultsAt. |
|
Gets or sets the StoreResultsAtAllFrequencies. |
|
Gets or sets the Strain. |
|
Gets or sets the Stress. |
|
Gets or sets the StructuralDampingCoefficient. |
|
Gets or sets the StructuralOnly. |
|
Gets or sets the TStress. |
|
Gets or sets the TemperatureConvergence. |
|
Gets or sets the TemperatureConvergenceInputValue. |
|
Gets or sets the TemperatureConvergenceMinimumReference. |
|
Gets or sets the TemperatureConvergenceTolerance. |
|
Gets or sets the TemperatureConvergenceValue. |
|
Gets or sets the ThermalOnly. |
|
Gets or sets the TimeIntegration. |
|
Gets or sets the TimeStep. |
|
Gets or sets the TransientApplication. |
|
Gets or sets the TransientApplicationUserDefined. |
|
Gets or sets the specification for updating the view factor. |
|
Gets or sets the UserDefinedFrequencies. |
|
Gets or sets the UserDefinedFrequencySteps. |
|
Gets or sets the ViewFactorMethod. |
|
Gets the list of properties that are visible for this object. |
|
Gets or sets the VoltageConvergence. |
|
Gets or sets the VoltageConvergenceMinimumReference. |
|
Gets or sets the VoltageConvergenceTolerance. |
|
Gets or sets the VoltageConvergenceValue. |
|
Gets or sets the WeakSprings. |
Property detail#
- property ANSYSAnalysisSettings.AMCooldownNumberOfSubsteps: int | None#
Gets or sets the AM Cooldown Number of Substeps.
- property ANSYSAnalysisSettings.AMPSConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the AMPSConvergence.
- property ANSYSAnalysisSettings.AMStepType: Ansys.Mechanical.DataModel.Enums.AMProcessStepType | None#
Gets or sets the AM Process Step Type.
- property ANSYSAnalysisSettings.AMSubstepsBetweenHeating: int | None#
Gets or sets the AM Substeps Between Heating.
- property ANSYSAnalysisSettings.AMSubstepsToApplyHeats: int | None#
Gets or sets the AM Substeps to Apply Heat.
- property ANSYSAnalysisSettings.AggressiveRemeshing: bool | None#
Gets or sets the AggressiveRemeshing.
- property ANSYSAnalysisSettings.AutomaticTimeStepping: Ansys.Mechanical.DataModel.Enums.AutomaticTimeStepping | None#
Gets or sets the AutomaticTimeStepping.
- property ANSYSAnalysisSettings.AxisymmetryDivisions: int | None#
Gets or sets the AxisymmetryDivisions.
- property ANSYSAnalysisSettings.BaseRemovalType: Ansys.Mechanical.DataModel.Enums.AMBaseRemovalType | None#
Gets or sets the BaseRemovalType.
- property ANSYSAnalysisSettings.BoundaryAngle: Ansys.Core.Units.Quantity | None#
Gets or sets the BoundaryAngle.
- property ANSYSAnalysisSettings.CSGConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the CSGConvergence.
- property ANSYSAnalysisSettings.CacheResultsInMemory: Ansys.Mechanical.DataModel.Enums.CacheResultsInMemory | None#
Gets or sets the CacheResultsInMemory.
- property ANSYSAnalysisSettings.CalculateAcceleration: bool | None#
Gets or sets the CalculateAcceleration.
- property ANSYSAnalysisSettings.CalculateEulerAngles: bool | None#
Gets or sets the CalculateEulerAngles.
- property ANSYSAnalysisSettings.CalculateReactions: bool | None#
Gets or sets the CalculateReactions.
- property ANSYSAnalysisSettings.CalculateThermalFlux: bool | None#
Gets or sets the CalculateThermalFlux.
- property ANSYSAnalysisSettings.CalculateVelocityAndAcceleration: bool | None#
Gets or sets the CalculateVelocityAndAcceleration.
- property ANSYSAnalysisSettings.CalculateVolumeEnergy: bool | None#
Gets or sets the CalculateVolumeEnergy.
- property ANSYSAnalysisSettings.CentralFrequency: Ansys.Core.Units.Quantity | None#
Gets or sets the CentralFrequency.
- property ANSYSAnalysisSettings.ChargeConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the ChargeConvergence.
- property ANSYSAnalysisSettings.ChargeConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the ChargeConvergenceMinimumReference.
- property ANSYSAnalysisSettings.ChargeConvergenceTolerance: float | None#
Gets or sets the ChargeConvergenceTolerance.
- property ANSYSAnalysisSettings.ChargeConvergenceValue: Ansys.Core.Units.Quantity | None#
Gets or sets the ChargeConvergenceValue.
- property ANSYSAnalysisSettings.Children: List[Ansys.Mechanical.DataModel.Interfaces.IDataModelObject] | None#
Gets the list of children.
- property ANSYSAnalysisSettings.CombineRestartFiles: Ansys.Mechanical.DataModel.Enums.CombineRestartFilesType | None#
Gets or sets the CombineRestartFiles.
- property ANSYSAnalysisSettings.Comments: Iterable[Ansys.ACT.Automation.Mechanical.Comment] | None#
Gets the list of associated comments.
- property ANSYSAnalysisSettings.ConstantDamping: Ansys.Mechanical.DataModel.Enums.ConstantDampingType | None#
Gets or sets the ConstantDamping.
- property ANSYSAnalysisSettings.ConstantDampingRatio: float | None#
Gets or sets the ConstantDampingRatio.
- property ANSYSAnalysisSettings.ContactMiscellaneous: bool | None#
Gets or sets the ContactMiscellaneous.
- property ANSYSAnalysisSettings.ContactSplit: Ansys.Mechanical.DataModel.Enums.ContactSplitType | None#
Gets or sets the ContactSplit.
- property ANSYSAnalysisSettings.ContactSummary: Ansys.Mechanical.DataModel.Enums.ContactSummaryType | None#
Gets or sets the ContactSummary.
- property ANSYSAnalysisSettings.CooldownTime: Ansys.Core.Units.Quantity | None#
Gets or sets the AM Cooldown Time.
- property ANSYSAnalysisSettings.CooldownTimeType: Ansys.Mechanical.DataModel.Enums.AMCooldownTimeType | None#
Gets or sets the AM Cooldown Time Type.
- property ANSYSAnalysisSettings.CoriolisEffectApplied: Ansys.Mechanical.DataModel.Enums.CoriolisEffectType | None#
Gets or sets the CoriolisEffectApplied.
- property ANSYSAnalysisSettings.CreepEffects: Ansys.Mechanical.DataModel.Enums.Creep | None#
Gets or sets the CreepEffects.
- property ANSYSAnalysisSettings.CurrentConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the CurrentConvergence.
- property ANSYSAnalysisSettings.CurrentConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the CurrentConvergenceMinimumReference.
- property ANSYSAnalysisSettings.CurrentConvergenceTolerance: float | None#
Gets or sets the CurrentConvergenceTolerance.
- property ANSYSAnalysisSettings.CurrentConvergenceValue: Ansys.Core.Units.Quantity | None#
Gets or sets the CurrentConvergenceValue.
- property ANSYSAnalysisSettings.CurrentRestartPoint: int | None#
Gets or sets the Current Restart Point.
- property ANSYSAnalysisSettings.CurrentStepNumberHarmonic: int | None#
Gets or sets the CurrentStepNumberHarmonic.
- property ANSYSAnalysisSettings.CyclicModeSuperposition: bool | None#
Gets or sets the CyclicModeSuperposition.
- property ANSYSAnalysisSettings.DampingDefineBy: Ansys.Mechanical.DataModel.Enums.DampingDefineBy | None#
Gets or sets the DampingDefineBy.
- property ANSYSAnalysisSettings.DataModelObjectCategory: Ansys.Mechanical.DataModel.Enums.DataModelObjectCategory | None#
Gets the current DataModelObject's category.
- property ANSYSAnalysisSettings.DefineBy: Ansys.Mechanical.DataModel.Enums.TimeStepDefineByType | None#
Gets or sets the DefineBy.
- property ANSYSAnalysisSettings.DeleteUnneededFiles: bool | None#
Gets or sets the DeleteUnneededFiles.
- property ANSYSAnalysisSettings.DisplacementConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the DisplacementConvergence.
- property ANSYSAnalysisSettings.DisplacementConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the DisplacementConvergenceMinimumReference.
- property ANSYSAnalysisSettings.DisplacementConvergenceTolerance: Ansys.Core.Units.Quantity | None#
Gets or sets the DisplacementConvergenceTolerance.
- property ANSYSAnalysisSettings.DisplacementConvergenceValue: Ansys.Core.Units.Quantity | None#
Gets or sets the DisplacementConvergenceValue.
- property ANSYSAnalysisSettings.EdgeSplittingAngle: Ansys.Core.Units.Quantity | None#
Gets or sets the EdgeSplittingAngle.
- property ANSYSAnalysisSettings.ElectromagneticNodalForces: bool | None#
Gets or sets the ElectromagneticNodalForces.
- property ANSYSAnalysisSettings.ElementCurrentDensity: bool | None#
Gets or sets the ElementCurrentDensity.
- property ANSYSAnalysisSettings.EmagAMPSConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the EmagAMPSConvergenceMinimumReference.
- property ANSYSAnalysisSettings.EmagAMPSConvergenceTolerance: float | None#
Gets or sets the EmagAMPSConvergenceTolerance.
- property ANSYSAnalysisSettings.EmagAMPSConvergenceValue: Ansys.Core.Units.Quantity | None#
Gets or sets the EmagAMPSConvergenceValue.
- property ANSYSAnalysisSettings.EmagCSGConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the EmagCSGConvergenceMinimumReference.
- property ANSYSAnalysisSettings.EmagCSGConvergenceTolerance: float | None#
Gets or sets the EmagCSGConvergenceTolerance.
- property ANSYSAnalysisSettings.EmagCSGConvergenceValue: Ansys.Core.Units.Quantity | None#
Gets or sets the EmagCSGConvergenceValue.
- property ANSYSAnalysisSettings.EnergyConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the EnergyConvergence.
- property ANSYSAnalysisSettings.EnergyConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the EnergyConvergenceMinimumReference.
- property ANSYSAnalysisSettings.EnergyConvergenceTolerance: float | None#
Gets or sets the EnergyConvergenceTolerance.
- property ANSYSAnalysisSettings.EnergyConvergenceValue: Ansys.Core.Units.Quantity | None#
Gets or sets the EnergyConvergenceValue.
- property ANSYSAnalysisSettings.EngineOrderofExcitation: int | None#
Gets or sets the EngineOrderofExcitation.
- property ANSYSAnalysisSettings.EqvDampingRatioFromModal: bool | None#
Gets or sets the EqvDampingRatioFromModal.
- property ANSYSAnalysisSettings.ExcludeInsignificantModes: bool | None#
Gets or sets the ExcludeInsignificantModes.
- property ANSYSAnalysisSettings.ExpandResultsFrom: Ansys.Mechanical.DataModel.Enums.ExpandResultFrom | None#
Gets or sets the ExpandResultsFrom.
- property ANSYSAnalysisSettings.Expansion: Ansys.Mechanical.DataModel.Enums.ExpandResultsSubType | None#
Gets the Expansion.
- property ANSYSAnalysisSettings.ExportLayerEndTemperature: bool | None#
Gets or sets the ExportLayerEndTemperature.
- property ANSYSAnalysisSettings.ExportRecoaterInterference: bool | None#
Gets or sets the ExportRecoaterInterference.
- property ANSYSAnalysisSettings.FarFieldRadiationSurface: Ansys.Mechanical.DataModel.Enums.FarFieldRadiationSurfaceType | None#
Gets or sets the FarFieldRadiationSurface.
- property ANSYSAnalysisSettings.FieldIntensityandFluxDensity: bool | None#
Gets or sets the FieldIntensityandFluxDensity.
- property ANSYSAnalysisSettings.Figures: Iterable[Ansys.ACT.Automation.Mechanical.Figure] | None#
Gets the list of associated figures.
- property ANSYSAnalysisSettings.ForceConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the ForceConvergence.
- property ANSYSAnalysisSettings.ForceConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the ForceConvergenceMinimumReference.
- property ANSYSAnalysisSettings.ForceConvergenceTolerance: Ansys.Core.Units.Quantity | None#
Gets or sets the ForceConvergenceTolerance.
- property ANSYSAnalysisSettings.ForceConvergenceValue: Ansys.Core.Units.Quantity | None#
Gets or sets the ForceConvergenceValue.
- property ANSYSAnalysisSettings.FractureSolverControls: bool | None#
Gets or sets the FractureSolverControls.
- property ANSYSAnalysisSettings.Frequency: Ansys.Core.Units.Quantity | None#
Gets or sets the Frequency.
- property ANSYSAnalysisSettings.FrequencySpacing: Ansys.Mechanical.DataModel.Enums.FrequencySpacingType | None#
Gets or sets the FrequencySpacing.
- property ANSYSAnalysisSettings.FutureAnalysis: Ansys.Mechanical.DataModel.Enums.FutureIntentType | None#
Gets or sets the FutureAnalysis.
- property ANSYSAnalysisSettings.GeneralMiscellaneous: bool | None#
Gets or sets the GeneralMiscellaneous.
- property ANSYSAnalysisSettings.GeneralMiscellaneousOption: Ansys.Mechanical.DataModel.Enums.GeneralMiscellaneousOptionType | None#
Gets or sets the GeneralMiscellaneousOption.
- property ANSYSAnalysisSettings.GenerateMeshRestartPoints: Ansys.Mechanical.DataModel.Enums.MeshRestartControlsType | None#
Gets or sets the GenerateMeshRestartPoints.
- property ANSYSAnalysisSettings.GenerateRestartPoints: Ansys.Mechanical.DataModel.Enums.RestartControlsType | None#
Gets or sets the GenerateRestartPoints.
- property ANSYSAnalysisSettings.GlobalSizeRatioQualityImprovement: float | None#
Gets or sets the GlobalSizeRatioQualityImprovement.
- property ANSYSAnalysisSettings.GlobalSizeRatioQualityRefinement: float | None#
Gets or sets the GlobalSizeRatioQualityRefinement.
- property ANSYSAnalysisSettings.Graph: Ansys.Mechanical.Graphics.AnalysisSettingsGraph | None#
Graph property.
- property ANSYSAnalysisSettings.HarmonicIndexInterval: int | None#
Gets or sets the HarmonicIndexInterval.
- property ANSYSAnalysisSettings.HarmonicIndexRange: Ansys.Mechanical.DataModel.Enums.CyclicHarmonicIndex | None#
Gets or sets the HarmonicIndexRange.
- property ANSYSAnalysisSettings.HeatConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the HeatConvergence.
- property ANSYSAnalysisSettings.HeatConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the HeatConvergenceMinimumReference.
- property ANSYSAnalysisSettings.HeatConvergenceTolerance: float | None#
Gets or sets the HeatConvergenceTolerance.
- property ANSYSAnalysisSettings.HeatConvergenceValue: Ansys.Core.Units.Quantity | None#
Gets or sets the HeatConvergenceValue.
- property ANSYSAnalysisSettings.HeatGenerationRate: bool | None#
Gets or sets the HeatGenerationRate.
- property ANSYSAnalysisSettings.IgnoreAcousticDamping: bool | None#
Gets or sets the IgnoreAcousticDamping.
- property ANSYSAnalysisSettings.Images: Iterable[Ansys.ACT.Automation.Mechanical.Image] | None#
Gets the list of associated images.
- property ANSYSAnalysisSettings.IncludeNegativeLoadMultiplier: Ansys.Mechanical.DataModel.Enums.SolverControlsIncludeNegativeLoadMultiplier | None#
Gets or sets the IncludeNegativeLoadMultiplier.
- property ANSYSAnalysisSettings.IncludeResidualVector: bool | None#
Gets or sets the IncludeResidualVector.
- property ANSYSAnalysisSettings.InitialTimeStep: Ansys.Core.Units.Quantity | None#
Gets or sets the InitialTimeStep.
- property ANSYSAnalysisSettings.InternalObject: Ansys.Common.Interop.DSObjectsAuto.IDSAnalysisSettings | None#
Gets the internal object. For advanced usage only.
- property ANSYSAnalysisSettings.InverseOptionEndStep: int | None#
Gets or sets the InverseOptionEndStep.
- property ANSYSAnalysisSettings.KeepPreStressLoadPattern: bool | None#
Gets or sets the KeepPreStressLoadPattern.
- property ANSYSAnalysisSettings.KrylovResidualTolerance: float | None#
Gets or sets the KrylovResidualTolerance.
- property ANSYSAnalysisSettings.KrylovSubspaceDimension: int | None#
Gets or sets the KrylovSubspaceDimension.
- property ANSYSAnalysisSettings.KrylovSubspaceFrequency: Ansys.Core.Units.Quantity | None#
Gets or sets the KrylovSubspaceFrequency.
- property ANSYSAnalysisSettings.LimitSearchToRange: bool | None#
Gets or sets the LimitSearchToRange.
- property ANSYSAnalysisSettings.LineSearch: Ansys.Mechanical.DataModel.Enums.LineSearchType | None#
Gets or sets the LineSearch.
- property ANSYSAnalysisSettings.MaximumHarmonicIndex: int | None#
Gets or sets the MaximumHarmonicIndex.
- property ANSYSAnalysisSettings.MaximumPointsToSavePerStep: int | None#
Gets or sets the MaximumPointsToSavePerStep.
- property ANSYSAnalysisSettings.MaximumTimeStep: Ansys.Core.Units.Quantity | None#
Gets or sets the MaximumTimeStep.
- property ANSYSAnalysisSettings.MeshRetainFilesAfterFullSolve: Ansys.Mechanical.DataModel.Enums.MeshRestartRetainFilesType | None#
Gets or sets the MeshRetainFilesAfterFullSolve.
- property ANSYSAnalysisSettings.MeshSaveAtLoadStep: Ansys.Mechanical.DataModel.Enums.MeshRestartSaveAtLoadStep | None#
Gets or sets the MeshSaveAtLoadStep.
- property ANSYSAnalysisSettings.MeshSaveAtSubstep: Ansys.Mechanical.DataModel.Enums.MeshRestartSaveAtSubstep | None#
Gets or sets the MeshSaveAtSubstep.
- property ANSYSAnalysisSettings.MinimumElementSize: Ansys.Core.Units.Quantity | None#
Gets or sets the Minimum Element Size property for Geometry Based Adaptivity.
- property ANSYSAnalysisSettings.MinimumHarmonicIndex: int | None#
Gets or sets the MinimumHarmonicIndex.
- property ANSYSAnalysisSettings.MinimumTimeStep: Ansys.Core.Units.Quantity | None#
Gets or sets the MinimumTimeStep.
- property ANSYSAnalysisSettings.ModalFrequencyRange: Ansys.Mechanical.DataModel.Enums.ModalFrequencyRangeType | None#
Gets or sets the ModalFrequencyRange.
- property ANSYSAnalysisSettings.ModalNumberOfPoints: int | None#
Gets or sets the ModalNumberOfPoints.
- property ANSYSAnalysisSettings.ModalRangeMaximum: Ansys.Core.Units.Quantity | None#
Gets or sets the ModalRangeMaximum.
- property ANSYSAnalysisSettings.ModalRangeMinimum: Ansys.Core.Units.Quantity | None#
Gets or sets the ModalRangeMinimum.
- property ANSYSAnalysisSettings.ModeReuse: Ansys.Mechanical.DataModel.Enums.SolverControlsModeReuse | None#
Gets or sets the ModeReuse.
- property ANSYSAnalysisSettings.ModeSelectionMethod: Ansys.Mechanical.DataModel.Enums.ModeSelectionMethod | None#
Gets or sets the ModeSelectionMethod.
- property ANSYSAnalysisSettings.ModeSignificanceLevel: float | None#
Gets or sets the ModeSignificanceLevel.
- property ANSYSAnalysisSettings.ModesCombinationType: Ansys.Mechanical.DataModel.Enums.ModesCombinationType | None#
Gets or sets the ModesCombinationType.
- property ANSYSAnalysisSettings.MomentConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the MomentConvergence.
- property ANSYSAnalysisSettings.MomentConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the MomentConvergenceMinimumReference.
- property ANSYSAnalysisSettings.MomentConvergenceTolerance: Ansys.Core.Units.Quantity | None#
Gets or sets the MomentConvergenceTolerance.
- property ANSYSAnalysisSettings.MomentConvergenceValue: Ansys.Core.Units.Quantity | None#
Gets or sets the MomentConvergenceValue.
- property ANSYSAnalysisSettings.MultistepType: Ansys.Mechanical.DataModel.Enums.HarmonicMultiStepType | None#
Gets or sets the MultistepType.
- property ANSYSAnalysisSettings.NamedSelection: Iterable[Ansys.ACT.Automation.Mechanical.NamedSelection] | None#
Gets or sets the objects of type NamedSelection to – Named Selection property in the Output Controls group of Analysis Settings. If the OutputSelection != OutputSelection.NamedSelection or NamedSelectionOnModeFile, 1. NamedSelection cannot be set. An exception will be thrown saying “Cannot modify ANSYSAnalysisSettings.NamedSelection if ANSYSAnalysisSettings.OutputSelection is not set to “OutputSelection.NamedSelection”.” 2. Getting the NamedSelection value will return an empty list.
- property ANSYSAnalysisSettings.NewtonRaphsonOption: Ansys.Mechanical.DataModel.Enums.NewtonRaphsonType | None#
Gets or sets the NewtonRaphsonOption.
- property ANSYSAnalysisSettings.NodalForces: Ansys.Mechanical.DataModel.Enums.OutputControlsNodalForcesType | None#
Gets or sets the NodalForces.
- property ANSYSAnalysisSettings.NonLinearFormulation: Ansys.Mechanical.DataModel.Enums.NonLinearFormulationType | None#
Gets or sets the NonLinearFormulation.
- property ANSYSAnalysisSettings.NumberOfSculptedLayersQualityImprovement: int | None#
Gets or sets the NumberOfSculptedLayersQualityImprovement.
- property ANSYSAnalysisSettings.NumberOfSculptedLayersRefinement: int | None#
Gets or sets the NumberOfSculptedLayersRefinement.
- property ANSYSAnalysisSettings.NumericalDamping: Ansys.Mechanical.DataModel.Enums.TransientDampingType | None#
Gets or sets the NumericalDamping.
- property ANSYSAnalysisSettings.NumericalDampingValue: float | None#
Gets or sets the NumericalDampingValue.
- property ANSYSAnalysisSettings.OnDemandExpansionOption: Ansys.Mechanical.DataModel.Enums.OnDemandExpansionType | None#
Gets or sets the OnDemandExpansionOption.
- property ANSYSAnalysisSettings.OutputSelection: Ansys.Mechanical.DataModel.Enums.OutputSelection | None#
Gets or sets the Output Selection property in the Output Controls group of Analysis Settings.
- property ANSYSAnalysisSettings.ParticipationFactor: Ansys.Mechanical.DataModel.Enums.CalculateParticipationFactorResult | None#
Gets or sets the ParticipationFactor.
- property ANSYSAnalysisSettings.ProjectToGeometry: Ansys.Mechanical.DataModel.Enums.NLADControlProjectToGeometry | None#
Gets or sets the ProjectToGeometry.
- property ANSYSAnalysisSettings.Properties: tuple[Ansys.ACT.Automation.Mechanical.Property] | None#
Gets the list of properties for this object.
- property ANSYSAnalysisSettings.QuasiStaticSolution: bool | None#
Gets or sets the QuasiStaticSolution.
- property ANSYSAnalysisSettings.RadiositySolver: Ansys.Mechanical.DataModel.Enums.RadiositySolverType | None#
Gets or sets the RadiositySolver.
- property ANSYSAnalysisSettings.RangeMaximum: Ansys.Core.Units.Quantity | None#
Gets or sets the Range Maximum property in Options group of Analysis Settings in Harmonic Analysis.
- property ANSYSAnalysisSettings.RangeMinimum: Ansys.Core.Units.Quantity | None#
Gets or sets the Range Minimum property in Options group of Analysis Settings in Harmonic Analysis.
- property ANSYSAnalysisSettings.ReferenceTemperature: Ansys.Core.Units.Quantity | None#
Gets or sets the AM Reference Temperature.
- property ANSYSAnalysisSettings.ReferenceTemperatureType: Ansys.Mechanical.DataModel.Enums.AMReferenceTemperatureType | None#
Gets or sets the AM Reference Temperature Type.
- property ANSYSAnalysisSettings.RefinementAlgorithm: Ansys.Mechanical.DataModel.Enums.NonlinearAdaptivityControlsRefinementAlgorithmType | None#
Gets or sets the RefinementAlgorithm.
- property ANSYSAnalysisSettings.ReformulationTolerance: float | None#
Gets or sets the ReformulationTolerance.
- property ANSYSAnalysisSettings.RelaxationTemperature: Ansys.Core.Units.Quantity | None#
Gets or sets the RelaxationTemperature.
- property ANSYSAnalysisSettings.RelaxationTemperatureType: Ansys.Mechanical.DataModel.Enums.AMRelaxationTemperatureType | None#
Gets or sets the AM Relaxation Temperature Type.
- property ANSYSAnalysisSettings.RemeshingGradient: Ansys.Mechanical.DataModel.Enums.NonlinearAdaptivityControlsRemeshingGradientType | None#
Gets or sets the RemeshingGradient.
- property ANSYSAnalysisSettings.RemeshingToleranceQualityImprovement: float | None#
Gets or sets the RemeshingToleranceQualityImprovement.
- property ANSYSAnalysisSettings.RemeshingToleranceRefinement: float | None#
Gets or sets the RemeshingToleranceRefinement.
- property ANSYSAnalysisSettings.RemovalDirection: Ansys.Core.Units.Quantity | None#
Gets or sets the RemovalDirection.
- property ANSYSAnalysisSettings.RemovalStepSize: Ansys.Core.Units.Quantity | None#
Gets or sets the RemovalStepSize.
- property ANSYSAnalysisSettings.RestartType: Ansys.Mechanical.DataModel.Enums.RestartType | None#
Gets or sets the RestartType.
- property ANSYSAnalysisSettings.ResultFileCompression: Ansys.Mechanical.DataModel.Enums.ResultFileCompressionType | None#
Gets or sets the ResultFileCompression.
- property ANSYSAnalysisSettings.RetainFilesAfterFullSolve: Ansys.Mechanical.DataModel.Enums.RestartRetainFilesType | None#
Gets or sets the RetainFilesAfterFullSolve.
- property ANSYSAnalysisSettings.RetainModesymFileAfterSolve: Ansys.Mechanical.DataModel.Enums.UseExistingModesymFile | None#
Gets or sets the RetainModesymFileAfterSolve.
- property ANSYSAnalysisSettings.RotationConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the RotationConvergence.
- property ANSYSAnalysisSettings.RotationConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the RotationConvergenceMinimumReference.
- property ANSYSAnalysisSettings.RotationConvergenceTolerance: Ansys.Core.Units.Quantity | None#
Gets or sets the RotationConvergenceTolerance.
- property ANSYSAnalysisSettings.RpmCentralFrequency: Ansys.Core.Units.Quantity | None#
Gets or sets the RpmCentralFrequency.
- property ANSYSAnalysisSettings.RpmFrequencySpacing: Ansys.Mechanical.DataModel.Enums.FrequencySpacingType | None#
Gets or sets the RpmFrequencySpacing.
- property ANSYSAnalysisSettings.RpmRangeMaximum: Ansys.Core.Units.Quantity | None#
Gets or sets the RpmRangeMaximum.
- property ANSYSAnalysisSettings.RpmRangeMinimum: Ansys.Core.Units.Quantity | None#
Gets or sets the RpmRangeMinimum.
- property ANSYSAnalysisSettings.RpmSolutionIntervals: int | None#
Gets or sets the RpmSolutionIntervals.
- property ANSYSAnalysisSettings.RpmValue: Ansys.Core.Units.Quantity | None#
Gets or sets the RpmValue.
- property ANSYSAnalysisSettings.SaveAtLoadStep: Ansys.Mechanical.DataModel.Enums.RestartSaveAtLoadStep | None#
Gets or sets the SaveAtLoadStep.
- property ANSYSAnalysisSettings.SaveAtSubstep: Ansys.Mechanical.DataModel.Enums.RestartSaveAtSubstep | None#
Gets or sets the SaveAtSubstep.
- property ANSYSAnalysisSettings.SaveSpecifiedLoadStep: int | None#
Gets or sets the SaveSpecifiedLoadStep.
- property ANSYSAnalysisSettings.ScatteredFieldFormulation: Ansys.Mechanical.DataModel.Enums.ScatteredFieldFormulation | None#
Gets or sets the ScatteredFieldFormulation.
- property ANSYSAnalysisSettings.ScatteringOutputType: Ansys.Mechanical.DataModel.Enums.ScatteringOutputType | None#
Gets or sets the ScatteringOutputType.
- property ANSYSAnalysisSettings.ScratchSolverFilesDirectory: str | None#
Gets the ScratchSolverFilesDirectory.
- property ANSYSAnalysisSettings.SearchRangeMaximum: Ansys.Core.Units.Quantity | None#
Gets or sets the Range Maximum property in Options group of Analysis Settings in Modal Analysis.
- property ANSYSAnalysisSettings.SearchRangeMinimum: Ansys.Core.Units.Quantity | None#
Gets or sets the Range Minimum property in Options group of Analysis Settings in Modal Analysis.
- property ANSYSAnalysisSettings.SignificanceThreshold: float | None#
Gets or sets the SignificanceThreshold.
- property ANSYSAnalysisSettings.SolutionMethod: Ansys.Mechanical.DataModel.Enums.HarmonicMethod | None#
Gets or sets the SolutionMethod.
- property ANSYSAnalysisSettings.SolverPivotChecking: Ansys.Mechanical.DataModel.Enums.SolverPivotChecking | None#
Gets or sets the SolverPivotChecking.
- property ANSYSAnalysisSettings.SolverTolerance: Ansys.Core.Units.Quantity | None#
Gets or sets the SolverTolerance.
- property ANSYSAnalysisSettings.SolverType: Ansys.Mechanical.DataModel.Enums.SolverType | None#
Gets or sets the SolverType.
- property ANSYSAnalysisSettings.SolverUnitSystem: Ansys.Mechanical.DataModel.Enums.WBUnitSystemType | None#
Gets or sets the SolverUnitSystem.
- property ANSYSAnalysisSettings.SolverUnits: Ansys.Mechanical.DataModel.Enums.SolverUnitsControlType | None#
Gets or sets the SolverUnits.
- property ANSYSAnalysisSettings.SpectrumType: Ansys.Mechanical.DataModel.Enums.SpectrumType | None#
Gets or sets the SpectrumType.
- property ANSYSAnalysisSettings.SpinSoftening: Ansys.Mechanical.DataModel.Enums.SpinSofteningType | None#
Gets or sets the SpinSoftening.
- property ANSYSAnalysisSettings.SpringStiffness: Ansys.Mechanical.DataModel.Enums.SpringsStiffnessType | None#
Gets or sets the SpringStiffness.
- property ANSYSAnalysisSettings.SpringStiffnessFactor: float | None#
Gets or sets the SpringStiffnessFactor.
- property ANSYSAnalysisSettings.SpringStiffnessValue: Ansys.Core.Units.Quantity | None#
Gets or sets the SpringStiffnessValue.
- property ANSYSAnalysisSettings.Stabilization: Ansys.Mechanical.DataModel.Enums.StabilizationType | None#
Gets or sets the Stabilization.
- property ANSYSAnalysisSettings.StabilizationActivationForFirstSubstep: Ansys.Mechanical.DataModel.Enums.StabilizationFirstSubstepOption | None#
Gets or sets the StabilizationActivationForFirstSubstep.
- property ANSYSAnalysisSettings.StabilizationDampingFactor: float | None#
Gets or sets the StabilizationDampingFactor.
- property ANSYSAnalysisSettings.StabilizationEnergyDissipationRatio: float | None#
Gets or sets the StabilizationEnergyDissipationRatio.
- property ANSYSAnalysisSettings.StabilizationForceLimit: float | None#
Gets or sets the StabilizationForceLimit.
- property ANSYSAnalysisSettings.StabilizationMethod: Ansys.Mechanical.DataModel.Enums.StabilizationMethod | None#
Gets or sets the StabilizationMethod.
- property ANSYSAnalysisSettings.StepEndTime: Ansys.Core.Units.Quantity | None#
Gets or sets the StepEndTime.
- property ANSYSAnalysisSettings.StiffnessCoefficient: float | None#
Gets or sets the StiffnessCoefficient.
- property ANSYSAnalysisSettings.StiffnessCoefficientDefineBy: Ansys.Mechanical.DataModel.Enums.DampingType | None#
Gets or sets the StiffnessCoefficientDefineBy.
- property ANSYSAnalysisSettings.StoreComplexSolution: bool | None#
Gets or sets the StoreComplexSolution.
- property ANSYSAnalysisSettings.StoreModalResults: Ansys.Mechanical.DataModel.Enums.StoreModalResult | None#
Gets or sets the StoreModalResults.
- property ANSYSAnalysisSettings.StoreResultsAt: Ansys.Mechanical.DataModel.Enums.TimePointsOptions | None#
Gets or sets the StoreResultsAt.
- property ANSYSAnalysisSettings.StoreResultsAtAllFrequencies: Ansys.Mechanical.DataModel.Enums.HarmonicMSUPStorage | None#
Gets or sets the StoreResultsAtAllFrequencies.
- property ANSYSAnalysisSettings.StructuralDampingCoefficient: float | None#
Gets or sets the StructuralDampingCoefficient.
- property ANSYSAnalysisSettings.TemperatureConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the TemperatureConvergence.
- property ANSYSAnalysisSettings.TemperatureConvergenceInputValue: Ansys.Core.Units.Quantity | None#
Gets or sets the TemperatureConvergenceInputValue.
- property ANSYSAnalysisSettings.TemperatureConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the TemperatureConvergenceMinimumReference.
- property ANSYSAnalysisSettings.TemperatureConvergenceTolerance: float | None#
Gets or sets the TemperatureConvergenceTolerance.
- property ANSYSAnalysisSettings.TemperatureConvergenceValue: Ansys.Mechanical.DataModel.Enums.NonLinearValueType | None#
Gets or sets the TemperatureConvergenceValue.
- property ANSYSAnalysisSettings.TimeStep: Ansys.Core.Units.Quantity | None#
Gets or sets the TimeStep.
- property ANSYSAnalysisSettings.TransientApplication: Ansys.Mechanical.DataModel.Enums.TransientApplicationType | None#
Gets or sets the TransientApplication.
- property ANSYSAnalysisSettings.TransientApplicationUserDefined: float | None#
Gets or sets the TransientApplicationUserDefined.
- property ANSYSAnalysisSettings.UpdateViewFactor: Ansys.Mechanical.DataModel.Enums.UpdateViewFactor | None#
Gets or sets the specification for updating the view factor.
- property ANSYSAnalysisSettings.UserDefinedFrequencies: bool | None#
Gets or sets the UserDefinedFrequencies.
- property ANSYSAnalysisSettings.UserDefinedFrequencySteps: List[Ansys.Core.Units.Quantity] | None#
Gets or sets the UserDefinedFrequencySteps.
- property ANSYSAnalysisSettings.ViewFactorMethod: Ansys.Mechanical.DataModel.Enums.RadiosityViewFactorType | None#
Gets or sets the ViewFactorMethod.
- property ANSYSAnalysisSettings.VisibleProperties: tuple[Ansys.ACT.Automation.Mechanical.Property] | None#
Gets the list of properties that are visible for this object.
- property ANSYSAnalysisSettings.VoltageConvergence: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType | None#
Gets or sets the VoltageConvergence.
- property ANSYSAnalysisSettings.VoltageConvergenceMinimumReference: Ansys.Core.Units.Quantity | None#
Gets or sets the VoltageConvergenceMinimumReference.
- property ANSYSAnalysisSettings.VoltageConvergenceTolerance: float | None#
Gets or sets the VoltageConvergenceTolerance.
- property ANSYSAnalysisSettings.VoltageConvergenceValue: Ansys.Core.Units.Quantity | None#
Gets or sets the VoltageConvergenceValue.
- property ANSYSAnalysisSettings.WeakSprings: Ansys.Mechanical.DataModel.Enums.WeakSpringsType | None#
Gets or sets the WeakSprings.
Method detail#
- ANSYSAnalysisSettings.AddComment() Ansys.ACT.Automation.Mechanical.Comment #
Creates a new child Comment.
- ANSYSAnalysisSettings.AddFigure() Ansys.ACT.Automation.Mechanical.Figure #
Creates a new child Figure.
- ANSYSAnalysisSettings.AddImage(filePath: str) Ansys.ACT.Automation.Mechanical.Image #
Creates a new child Image.
If a filePath is provided, the image will be loaded from that file,
if not, the image will be a screen capture of the Geometry window.
- ANSYSAnalysisSettings.CopyTo(other: Ansys.ACT.Automation.Mechanical.DataModelObject) None #
CopyTo method.
- ANSYSAnalysisSettings.CreateParameter(propName: str) Ansys.ACT.Interfaces.Mechanical.IParameter #
Creates a new parameter for a Property.
- ANSYSAnalysisSettings.Duplicate() Ansys.Mechanical.DataModel.Interfaces.IDataModelObject #
Creates a copy of the current DataModelObject.
- ANSYSAnalysisSettings.GetAMStepType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.AMProcessStepType #
Gets the AM Process Step Type at a given step.
- ANSYSAnalysisSettings.GetAutomaticTimeStepping(stepNumber: int) Ansys.Mechanical.DataModel.Enums.AutomaticTimeStepping #
Gets the Automatic Time Stepping at a given solution step.
- ANSYSAnalysisSettings.GetCarryOverTimeStep(stepNumber: int) bool #
Gets the Carry Over Time Step at a given solution step.
- ANSYSAnalysisSettings.GetChildren(recurses: bool, children: List[ChildrenType]) List[ChildrenType] #
Gets the list of children, filtered by type.
- ANSYSAnalysisSettings.GetCreepEffects(stepNumber: int) Ansys.Mechanical.DataModel.Enums.Creep #
Gets the Creep Effects for a given solution step.
- ANSYSAnalysisSettings.GetCreepLimitRatio(stepNumber: int) float #
Gets the Creep Limit Ratio for a given solution step.
- ANSYSAnalysisSettings.GetCurrentConvergenceMinimumReference(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Current Convergence Minimum Reference at a given solution step.
- ANSYSAnalysisSettings.GetCurrentConvergenceTolerance(stepNumber: int) float #
Gets the Current Convergence Tolerance as a percentage at a given solution step.
- ANSYSAnalysisSettings.GetCurrentConvergenceType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType #
Gets the Current Convergence Tolerance type at a given solution step.
- ANSYSAnalysisSettings.GetCurrentConvergenceValue(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Current Convergence Value at a given solution step.
- ANSYSAnalysisSettings.GetDefineBy(stepNumber: int) Ansys.Mechanical.DataModel.Enums.TimeStepDefineByType #
Gets the Define By at a given solution step.
- ANSYSAnalysisSettings.GetDisplacementConvergenceMinimumReference(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Displacement Convergence Minimum Reference at a given solution step.
- ANSYSAnalysisSettings.GetDisplacementConvergenceTolerance(stepNumber: int) float #
Gets the Displacement Convergence Tolerance as a percentage at a given solution step.
- ANSYSAnalysisSettings.GetDisplacementConvergenceType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType #
Gets the Displacement Convergence Tolerance type at a given solution step.
- ANSYSAnalysisSettings.GetDisplacementConvergenceValue(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Displacement Convergence Value at a given solution step.
- ANSYSAnalysisSettings.GetEmagAMPSConvergenceMinimumReference(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the EmagAMPS Convergence Minimum Reference at a given solution step.
- ANSYSAnalysisSettings.GetEmagAMPSConvergenceTolerance(stepNumber: int) float #
Gets the EmagAMPS Convergence Tolerance as a percentage at a given solution step.
- ANSYSAnalysisSettings.GetEmagAMPSConvergenceType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType #
Gets the EmagAMPS Convergence Tolerance type at a given solution step.
- ANSYSAnalysisSettings.GetEmagAMPSConvergenceValue(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the EmagAMPS Convergence Value at a given solution step.
- ANSYSAnalysisSettings.GetEmagCSGConvergenceMinimumReference(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the EmagCSG Convergence Minimum Reference at a given solution step.
- ANSYSAnalysisSettings.GetEmagCSGConvergenceTolerance(stepNumber: int) float #
Gets the EmagCSG Convergence Tolerance as a percentage at a given solution step.
- ANSYSAnalysisSettings.GetEmagCSGConvergenceType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType #
Gets the EmagCSG Convergence Tolerance type at a given solution step.
- ANSYSAnalysisSettings.GetEmagCSGConvergenceValue(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the EmagCSG Convergence Value at a given solution step.
- ANSYSAnalysisSettings.GetEnergyConvergenceMinimumReference(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Energy Convergence Minimum Reference at a given solution step.
- ANSYSAnalysisSettings.GetEnergyConvergenceTolerance(stepNumber: int) float #
Gets the Energy Convergence Tolerance as a percentage at a given solution step.
- ANSYSAnalysisSettings.GetEnergyConvergenceType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType #
Gets the Energy Convergence Tolerance type at a given solution step.
- ANSYSAnalysisSettings.GetEnergyConvergenceValue(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Energy Convergence Value at a given solution step.
- ANSYSAnalysisSettings.GetForceConvergenceMinimumReference(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Force Convergence Minimum Reference at a given solution step.
- ANSYSAnalysisSettings.GetForceConvergenceTolerance(stepNumber: int) float #
Gets the Force Convergence Tolerance as a percentage at a given solution step.
- ANSYSAnalysisSettings.GetForceConvergenceType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType #
Gets the Force Convergence Tolerance Type at a given solution step.
- ANSYSAnalysisSettings.GetForceConvergenceValue(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Force Convergence Value at a given solution step.
- ANSYSAnalysisSettings.GetHeatConvergenceMinimumReference(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Heat Convergence Minimum Reference at a given solution step.
- ANSYSAnalysisSettings.GetHeatConvergenceTolerance(stepNumber: int) float #
Gets the Heat Convergence Tolerance as a percentage at a given solution step.
- ANSYSAnalysisSettings.GetHeatConvergenceType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType #
Gets the Heat Convergence Tolerance type at a given solution step.
- ANSYSAnalysisSettings.GetHeatConvergenceValue(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Heat Convergence Value at a given solution step.
- ANSYSAnalysisSettings.GetInitialSubsteps(stepNumber: int) int #
Gets the Initial Substeps at a given solution step.
- ANSYSAnalysisSettings.GetInitialTimeStep(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Initial Time Step at a given solution step.
- ANSYSAnalysisSettings.GetLineSearch(stepNumber: int) Ansys.Mechanical.DataModel.Enums.LineSearchType #
Gets the Line Search at a given solution step.
- ANSYSAnalysisSettings.GetMaximumSubsteps(stepNumber: int) int #
Gets the Maximum Substeps at a given solution step.
- ANSYSAnalysisSettings.GetMaximumTimeStep(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Maximum Time Step at a given solution step.
- ANSYSAnalysisSettings.GetMinimumSubsteps(stepNumber: int) int #
Gets the Minimum Substeps at a given solution step.
- ANSYSAnalysisSettings.GetMinimumTimeStep(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Minimum Time Step at a given solution step.
- ANSYSAnalysisSettings.GetMomentConvergenceMinimumReference(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Moment Convergence Minimum Reference at a given solution step.
- ANSYSAnalysisSettings.GetMomentConvergenceTolerance(stepNumber: int) float #
Gets the Moment Convergence Tolerance as a percentage at a given solution step.
- ANSYSAnalysisSettings.GetMomentConvergenceType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType #
Gets the Moment Convergence Tolerance type at a given solution step.
- ANSYSAnalysisSettings.GetMomentConvergenceValue(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Moment Convergence Value at a given solution step.
- ANSYSAnalysisSettings.GetNumberOfSubSteps(stepNumber: int) int #
Gets the Number of Substeps for a given solution step.
- ANSYSAnalysisSettings.GetParameter(propName: str) Ansys.ACT.Interfaces.Mechanical.IParameter #
Gets the parameter corresponding to the given property.
- ANSYSAnalysisSettings.GetRotationConvergenceMinimumReference(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Rotation Convergence Minimum Reference at a given solution step.
- ANSYSAnalysisSettings.GetRotationConvergenceTolerance(stepNumber: int) float #
Gets the Rotation Convergence Tolerance as a percentage at a given solution step.
- ANSYSAnalysisSettings.GetRotationConvergenceType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType #
Gets the Rotation Convergence Tolerance type at a given solution step.
- ANSYSAnalysisSettings.GetRotationConvergenceValue(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Rotation Convergence Value at a given solution step.
- ANSYSAnalysisSettings.GetStabilization(stepNumber: int) Ansys.Mechanical.DataModel.Enums.StabilizationType #
Gets the Stabilization at a given solution step.
- ANSYSAnalysisSettings.GetStabilizationDampingFactor(stepNumber: int) float #
Gets the Stabilization Damping Factor at a given solution step.
- ANSYSAnalysisSettings.GetStabilizationEnergyDissipationRatio(stepNumber: int) float #
Gets the Stabilization Energy Dissipation Ratio at a given solution step.
- ANSYSAnalysisSettings.GetStabilizationFirstSubstepOption(stepNumber: int) Ansys.Mechanical.DataModel.Enums.StabilizationFirstSubstepOption #
Gets the Stabilization First Substep Option at a given solution step.
- ANSYSAnalysisSettings.GetStabilizationForceLimit(stepNumber: int) float #
Gets the Stabilization Force Limit at a given solution step.
- ANSYSAnalysisSettings.GetStabilizationMethod(stepNumber: int) Ansys.Mechanical.DataModel.Enums.StabilizationMethod #
Gets the Stabilization Method at a given solution step.
- ANSYSAnalysisSettings.GetStepEndTime(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Step End Time at a given solution step.
- ANSYSAnalysisSettings.GetStoreResulsAtValue(stepNumber: int) int #
Gets the Store Results At Value at a given solution step.
- ANSYSAnalysisSettings.GetStoreResultsAt(stepNumber: int) Ansys.Mechanical.DataModel.Enums.TimePointsOptions #
Gets the Store Results At at a given solution step.
- ANSYSAnalysisSettings.GetStructuralOnly(stepNumber: int) bool #
Gets the TimeIntegration Structural for a given solution step.
- ANSYSAnalysisSettings.GetTemperatureConvergenceInputValue(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Temperature Convergence Input Value at a given solution step.
- ANSYSAnalysisSettings.GetTemperatureConvergenceMinimumReference(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Temperature Convergence Minimum Reference at a given solution step.
- ANSYSAnalysisSettings.GetTemperatureConvergenceTolerance(stepNumber: int) float #
Gets the Temperature Convergence Tolerance as a percentage at a given solution step.
- ANSYSAnalysisSettings.GetTemperatureConvergenceType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType #
Gets the Temperature Convergence Tolerance type at a given solution step.
- ANSYSAnalysisSettings.GetTemperatureConvergenceValue(stepNumber: int) Ansys.Mechanical.DataModel.Enums.NonLinearValueType #
Gets the Temperature Convergence Value at a given solution step.
- ANSYSAnalysisSettings.GetThermalOnly(stepNumber: int) bool #
Sets the TimeIntegration Thermal for a given solution step.
- ANSYSAnalysisSettings.GetTimeIntegration(stepNumber: int) bool #
Gets the TimeIntegration for a given solution step.
- ANSYSAnalysisSettings.GetTimeStep(stepNumber: int) Ansys.Core.Units.Quantity #
Sets the Time Step for a given solution step.
- ANSYSAnalysisSettings.GetVoltageConvergenceMinimumReference(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Voltage Convergence Minimum Reference at a given solution step.
- ANSYSAnalysisSettings.GetVoltageConvergenceTolerance(stepNumber: int) float #
Gets the Voltage Convergence Tolerance as a percentage at a given solution step.
- ANSYSAnalysisSettings.GetVoltageConvergenceType(stepNumber: int) Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType #
Gets the Voltage Convergence Tolerance type at a given solution step.
- ANSYSAnalysisSettings.GetVoltageConvergenceValue(stepNumber: int) Ansys.Core.Units.Quantity #
Gets the Voltage Convergence Value at a given solution step.
- ANSYSAnalysisSettings.GroupSimilarObjects() Ansys.ACT.Automation.Mechanical.TreeGroupingFolder #
Run the GroupSimilarObjects action.
Get a property by its API name.
If multiple properties have the same API Name, only the first property with that name will be returned.
- ANSYSAnalysisSettings.PropertyByName(name: str) Ansys.ACT.Automation.Mechanical.Property #
Get a property by its unique name.
- ANSYSAnalysisSettings.RemoveParameter(propName: str) None #
Removes the parameter from the parameter set corresponding to the given property.
- ANSYSAnalysisSettings.SetAutomaticTimeStepping(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.AutomaticTimeStepping) None #
Sets the Automatic Time Stepping for a given solution step.
- ANSYSAnalysisSettings.SetCarryOverTimeStep(stepNumber: int, value: bool) None #
Sets the Carry Over Time Step for a given solution step.
- ANSYSAnalysisSettings.SetChargeConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Charge Convergence Minimum Reference for a given solution step.
Sets the Charge Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetChargeConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the Charge Convergence Tolerance type for a given solution step.
- ANSYSAnalysisSettings.SetChargeConvergenceValue(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Charge Convergence Value for a given solution step.
- ANSYSAnalysisSettings.SetCreepEffects(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.Creep) None #
Sets the Creep Effects for a given solution step.
- ANSYSAnalysisSettings.SetCreepLimitRatio(stepNumber: int, value: float) None #
Sets the Creep Limit Ratio for a given solution step.
- ANSYSAnalysisSettings.SetCurrentConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Current Convergence Minimum Reference for a given solution step.
Sets the Current Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetCurrentConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the Current Convergence Tolerance type for a given solution step.
- ANSYSAnalysisSettings.SetCurrentConvergenceValue(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Current Convergence Value for a given solution step.
- ANSYSAnalysisSettings.SetDefineBy(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.TimeStepDefineByType) None #
Sets the Define By for a given solution step.
- ANSYSAnalysisSettings.SetDisplacementConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Displacement Convergence Minimum Reference for a given solution step.
Sets the Displacement Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetDisplacementConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the Displacement Convergence Tolerance type for a given solution step.
- ANSYSAnalysisSettings.SetDisplacementConvergenceValue(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Displacement Convergence Value for a given solution step.
- ANSYSAnalysisSettings.SetEmagAMPSConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the EmagAMPS Convergence Minimum Reference for a given solution step.
Sets the EmagAMPS Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetEmagAMPSConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the EmagAMPS Convergence Tolerance type for a given solution step.
- ANSYSAnalysisSettings.SetEmagAMPSConvergenceValue(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the EmagAMPS Convergence Value for a given solution step.
- ANSYSAnalysisSettings.SetEmagCSGConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the EmagCSG Convergence Minimum Reference for a given solution step.
Sets the EmagCSG Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetEmagCSGConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the EmagCSG Convergence Tolerance type for a given solution step.
- ANSYSAnalysisSettings.SetEmagCSGConvergenceValue(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the EmagCSG Convergence Value for a given solution step.
- ANSYSAnalysisSettings.SetEnergyConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Energy Convergence Minimum Reference for a given solution step.
Sets the Energy Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetEnergyConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the Energy Convergence Tolerance type for a given solution step.
- ANSYSAnalysisSettings.SetEnergyConvergenceValue(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Energy Convergence Value for a given solution step.
- ANSYSAnalysisSettings.SetForceConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Force Convergence Minimum Reference for a given solution step.
Sets the Force Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetForceConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the Force Convergence Tolerance Type for a given solution step.
- ANSYSAnalysisSettings.SetForceConvergenceValue(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Force Convergence Value for a given solution step.
- ANSYSAnalysisSettings.SetHeatConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Heat Convergence Minimum Reference for a given solution step.
Sets the Heat Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetHeatConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the Heat Convergence Tolerance type for a given solution step.
- ANSYSAnalysisSettings.SetHeatConvergenceValue(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Heat Convergence Value for a given solution step.
- ANSYSAnalysisSettings.SetInitialSubsteps(stepNumber: int, value: int) None #
Sets the Initial Substeps for a given solution step.
- ANSYSAnalysisSettings.SetInitialTimeStep(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Initial Time Step for a given solution step.
- ANSYSAnalysisSettings.SetLineSearch(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.LineSearchType) None #
Sets the Line Search for a given solution step.
- ANSYSAnalysisSettings.SetMaximumSubsteps(stepNumber: int, value: int) None #
Sets the Maximum Substeps for a given solution step.
- ANSYSAnalysisSettings.SetMaximumTimeStep(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Maximum Time Step for a given solution step.
- ANSYSAnalysisSettings.SetMinimumSubsteps(stepNumber: int, value: int) None #
Sets the Minimum Substeps for a given solution step.
- ANSYSAnalysisSettings.SetMinimumTimeStep(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Minimum Time Step for a given solution step.
- ANSYSAnalysisSettings.SetMomentConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Moment Convergence Minimum Reference for a given solution step.
Sets the Moment Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetMomentConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the Moment Convergence Tolerance type for a given solution step.
- ANSYSAnalysisSettings.SetMomentConvergenceValue(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Moment Convergence Value for a given solution step.
- ANSYSAnalysisSettings.SetNumberOfSubSteps(stepNumber: int, value: int) None #
Sets the Number of Substeps for a given solution step.
- ANSYSAnalysisSettings.SetRotationConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Rotation Convergence Minimum Reference for a given solution step.
Sets the Rotation Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetRotationConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the Rotation Convergence Tolerance type for a given solution step.
- ANSYSAnalysisSettings.SetRotationConvergenceValue(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Rotation Convergence Value for a given solution step.
- ANSYSAnalysisSettings.SetStabilization(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.StabilizationType) None #
Sets the Stabilization for a given solution step.
- ANSYSAnalysisSettings.SetStabilizationDampingFactor(stepNumber: int, value: float) None #
Sets the Stabilization Damping Factor for a given solution step.
- ANSYSAnalysisSettings.SetStabilizationEnergyDissipationRatio(stepNumber: int, value: float) None #
Sets the Stabilization Energy Dissipation Ratio for a given solution step.
- ANSYSAnalysisSettings.SetStabilizationFirstSubstepOption(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.StabilizationFirstSubstepOption) None #
Sets the Stabilization First Substep Option for a given solution step.
- ANSYSAnalysisSettings.SetStabilizationForceLimit(stepNumber: int, value: float) None #
Sets the Stabilization Force Limit for a given solution step.
- ANSYSAnalysisSettings.SetStabilizationMethod(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.StabilizationMethod) None #
Sets the Stabilization Method for a given solution step.
- ANSYSAnalysisSettings.SetStepEndTime(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Step End Time for a given solution step.
- ANSYSAnalysisSettings.SetStepName(stepNumber: int, value: str) None #
Sets the Step name at a given step.
- ANSYSAnalysisSettings.SetStoreResulsAtValue(stepNumber: int, value: int) None #
Sets the Store Results At Value for a given solution step.
- ANSYSAnalysisSettings.SetStoreResultsAt(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.TimePointsOptions) None #
Sets the Store Results At for a given solution step.
- ANSYSAnalysisSettings.SetStructuralOnly(stepNumber: int, value: bool) None #
Sets the TimeIntegration Structural for a given solution step.
- ANSYSAnalysisSettings.SetTemperatureConvergenceInputValue(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Temperature Convergence Input Value for a given solution step.
- ANSYSAnalysisSettings.SetTemperatureConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Temperature Convergence Minimum Reference for a given solution step.
Sets the Temperature Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetTemperatureConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the Temperature Convergence Tolerance type for a given solution step.
- ANSYSAnalysisSettings.SetTemperatureConvergenceValue(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.NonLinearValueType) None #
Sets the Temperature Convergence Value for a given solution step.
- ANSYSAnalysisSettings.SetThermalOnly(stepNumber: int, value: bool) None #
Sets the TimeIntegration Thermal for a given solution step.
- ANSYSAnalysisSettings.SetTimeIntegration(stepNumber: int, value: bool) None #
Sets the TimeIntegration for a given solution step.
- ANSYSAnalysisSettings.SetTimeStep(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Time Step for a given solution step.
- ANSYSAnalysisSettings.SetVoltageConvergenceMinimumReference(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Voltage Convergence Minimum Reference for a given solution step.
Sets the Voltage Convergence Tolerance as a percentage for a given solution step.
For example if the user input is 5% then the "value" argument should be set to 5.
- ANSYSAnalysisSettings.SetVoltageConvergenceType(stepNumber: int, value: Ansys.Mechanical.DataModel.Enums.ConvergenceToleranceType) None #
Sets the Voltage Convergence Tolerance type for a given solution step.
- ANSYSAnalysisSettings.SetVoltageConvergenceValue(stepNumber: int, value: Ansys.Core.Units.Quantity) None #
Sets the Voltage Convergence Value for a given solution step.