Convection#
- class ansys.mechanical.stubs.v251.Ansys.ACT.Automation.Mechanical.BoundaryConditions.Convection#
 Bases:
objectDefines a Convection.
Overview#
Activate the current object.  | 
|
Creates a new child Comment.  | 
|
Creates a new child Figure.  | 
|
Creates a new child Image.  | 
|
Copies all visible properties from this object to another.  | 
|
Creates a new parameter for a Property.  | 
|
Run the Delete action.  | 
|
Creates a copy of the current DataModelObject.  | 
|
Gets whether the convection is active at the specified load step.  | 
|
Gets the list of children, filtered by type.  | 
|
GetComponentActivateAtLoadStep method.  | 
|
Gets the parameter corresponding to the given property.  | 
|
Run the GroupAllSimilarChildren action.  | 
|
Run the GroupSimilarObjects action.  | 
|
Run the PromoteToNamedSelection action.  | 
|
Get a property by its API name.  | 
|
Get a property by its unique name.  | 
|
Removes the parameter from the parameter set corresponding to the given property.  | 
|
Sets whether the convection is active at the specified load step.  | 
|
SetComponentActivateAtLoadStep method.  | 
Property used to get and set the ambient temperature data  | 
|
The coordinate system id used currently to determinine the position of the points of the ambient temperature variable  | 
|
Gets the list of children.  | 
|
Gets or sets the CoefficientType.  | 
|
Gets the list of associated comments.  | 
|
The coordinate system id used currently to determinine the position of the points of the convection coefficient variable  | 
|
Gets or sets the ConvectionMatrix.  | 
|
Gets the current DataModelObject's category.  | 
|
Gets or sets the DisplayConnectionLines.  | 
|
Gets or sets the EditDataFor.  | 
|
Gets or Sets the ElementAPDLName which stores the element type number of the convection load. This you can reference and use in Command Snippets.  | 
|
Gets the list of associated figures.  | 
|
Property used to get and set the film coefficient data  | 
|
Gets or sets the FluidFlowSelection.  | 
|
Gets or sets the GraphControlsXAxis.  | 
|
Gets or sets the HasFluidFlow.  | 
|
Gets the list of associated images.  | 
|
Gets or sets the IndependentVariable.  | 
|
InternalObject property.  | 
|
Gets or sets the Location.  | 
|
Gets or sets the NumberOfSegments.  | 
|
Gets the list of properties for this object.  | 
|
Gets or sets the RangeMaximum.  | 
|
Gets or sets the RangeMinimum.  | 
|
Gets or sets the ReadOnly.  | 
|
Gets or sets the SharedRefBody.  | 
|
Gets or sets the Suppressed.  | 
|
Gets the list of properties that are visible for this object.  | 
|
Gets or sets the XYZFunctionCoordinateSystem.  | 
Property detail#
- property Convection.AmbientTemperature: Any | None#
 Property used to get and set the ambient temperature data The setter allows the use of a table T:Ansys.ACT.Automation.Mechanical.Table object, an expression contained in a string or a quantity T:Ansys.Core.Units.Quantity object as a data source. Depending on the representation T:Ansys.Mechanical.DataModel.MechanicalEnums.BoundaryConditions.DataRepresentation type, the getter return type is a field T:Ansys.ACT.Mechanical.Fields.Field object or an object which type depends on the source of the ambient temperature data: - On table assignment mode, it returns the source table T:Ansys.ACT.Automation.Mechanical.Table object. - On function mode, it returns a string containing the expression evaluated to obtain the data. - On constant mode, it returns a quantity T:Ansys.Core.Units.Quantity object containg the value and the units currently assigned to the ambient temperature. - On tabular mode, it returns a tabularDataTable T:Ansys.ACT.Automation.Mechanical.TabularDataTable object.
- property Convection.AmbientTemperatureCoordinateSystem: Ansys.ACT.Automation.Mechanical.CoordinateSystem | None#
 The coordinate system id used currently to determinine the position of the points of the ambient temperature variable
- property Convection.Children: List[Ansys.Mechanical.DataModel.Interfaces.IDataModelObject] | None#
 Gets the list of children.
- property Convection.CoefficientType: Ansys.Mechanical.DataModel.Enums.LoadVariationSubOption | None#
 Gets or sets the CoefficientType.
- property Convection.Comments: Iterable[Ansys.ACT.Automation.Mechanical.Comment] | None#
 Gets the list of associated comments.
- property Convection.ConvectionCoefficientCoordinateSystem: Ansys.ACT.Automation.Mechanical.CoordinateSystem | None#
 The coordinate system id used currently to determinine the position of the points of the convection coefficient variable
- property Convection.ConvectionMatrix: Ansys.Mechanical.DataModel.Enums.DiagonalOrConsistent | None#
 Gets or sets the ConvectionMatrix.
- property Convection.DataModelObjectCategory: Ansys.Mechanical.DataModel.Enums.DataModelObjectCategory | None#
 Gets the current DataModelObject's category.
- property Convection.EditDataFor: Ansys.Mechanical.DataModel.Enums.ConvectionTableSelection | None#
 Gets or sets the EditDataFor.
- property Convection.ElementAPDLName: str | None#
 Gets or Sets the ElementAPDLName which stores the element type number of the convection load. This you can reference and use in Command Snippets.
- property Convection.Figures: Iterable[Ansys.ACT.Automation.Mechanical.Figure] | None#
 Gets the list of associated figures.
- property Convection.FilmCoefficient: Any | None#
 Property used to get and set the film coefficient data The setter allows the use of a table T:Ansys.ACT.Automation.Mechanical.Table object, an expression contained in a string or a quantity T:Ansys.Core.Units.Quantity object as a data source. Depending on the representation T:Ansys.Mechanical.DataModel.MechanicalEnums.BoundaryConditions.DataRepresentation type, the getter return type is a field T:Ansys.ACT.Mechanical.Fields.Field object or an object which type depends on the source of the film coefficient data: - On table assignment mode, it returns the source table T:Ansys.ACT.Automation.Mechanical.Table object. - On function mode, it returns a string containing the expression evaluated to obtain the data. - On constant mode, it returns a quantity T:Ansys.Core.Units.Quantity object containg the value and the units currently assigned to the film coefficient. - On tabular mode, it returns a tabularDataTable T:Ansys.ACT.Automation.Mechanical.TabularDataTable object.
- property Convection.FluidFlowSelection: Ansys.ACT.Interfaces.Common.ISelectionInfo | None#
 Gets or sets the FluidFlowSelection.
- property Convection.GraphControlsXAxis: Ansys.Mechanical.DataModel.Enums.LoadVariableVariationType | None#
 Gets or sets the GraphControlsXAxis.
- property Convection.Images: Iterable[Ansys.ACT.Automation.Mechanical.Image] | None#
 Gets the list of associated images.
- property Convection.IndependentVariable: Ansys.Mechanical.DataModel.Enums.LoadVariableVariationType | None#
 Gets or sets the IndependentVariable.
- property Convection.InternalObject: Ansys.Common.Interop.DSObjectsAuto.IDSLoadAuto | None#
 InternalObject property.
- property Convection.Location: Ansys.ACT.Interfaces.Common.ISelectionInfo | None#
 Gets or sets the Location.
- property Convection.Properties: tuple[Ansys.ACT.Automation.Mechanical.Property] | None#
 Gets the list of properties for this object.
- property Convection.RangeMaximum: Ansys.Core.Units.Quantity | None#
 Gets or sets the RangeMaximum.
- property Convection.RangeMinimum: Ansys.Core.Units.Quantity | None#
 Gets or sets the RangeMinimum.
Gets or sets the SharedRefBody.
- property Convection.VisibleProperties: tuple[Ansys.ACT.Automation.Mechanical.Property] | None#
 Gets the list of properties that are visible for this object.
- property Convection.XYZFunctionCoordinateSystem: Ansys.ACT.Automation.Mechanical.CoordinateSystem | None#
 Gets or sets the XYZFunctionCoordinateSystem.
Method detail#
- Convection.AddComment() Ansys.ACT.Automation.Mechanical.Comment#
 Creates a new child Comment.
- Convection.AddFigure() Ansys.ACT.Automation.Mechanical.Figure#
 Creates a new child Figure.
- Convection.AddImage(filePath: str) Ansys.ACT.Automation.Mechanical.Image#
 
Creates a new child Image.
If a filePath is provided, the image will be loaded from that file,
if not, the image will be a screen capture of the Geometry window.
- Convection.CopyTo(other: Ansys.ACT.Automation.Mechanical.DataModelObject) None#
 Copies all visible properties from this object to another.
- Convection.CreateParameter(propName: str) Ansys.ACT.Interfaces.Mechanical.IParameter#
 Creates a new parameter for a Property.
- Convection.Duplicate() Ansys.Mechanical.DataModel.Interfaces.IDataModelObject#
 Creates a copy of the current DataModelObject.
- Convection.GetActivateAtLoadStep(stepNumber: int) bool#
 Gets whether the convection is active at the specified load step.
- Convection.GetChildren(recurses: bool, children: List[ChildrenType]) List[ChildrenType]#
 Gets the list of children, filtered by type.
- Convection.GetComponentActivateAtLoadStep(component: str, stepNumber: int) bool#
 GetComponentActivateAtLoadStep method.
- Convection.GetParameter(propName: str) Ansys.ACT.Interfaces.Mechanical.IParameter#
 Gets the parameter corresponding to the given property.
- Convection.GroupSimilarObjects() Ansys.ACT.Automation.Mechanical.TreeGroupingFolder#
 Run the GroupSimilarObjects action.
- Convection.PromoteToNamedSelection() Iterable[Ansys.ACT.Automation.Mechanical.NamedSelection]#
 Run the PromoteToNamedSelection action.
Get a property by its API name.
If multiple properties have the same API Name, only the first property with that name will be returned.
- Convection.PropertyByName(name: str) Ansys.ACT.Automation.Mechanical.Property#
 Get a property by its unique name.
- Convection.RemoveParameter(propName: str) None#
 Removes the parameter from the parameter set corresponding to the given property.